11
CLEARANCES TO COMBUSTIBLES AND FLOOR PROTECTOR
To install your appliance correctly, it is extremely important to respect all clearances to any
combustibles as indicated on your stove’s certification label.
Clearances to combustible materials
(see figure 1.3 to match each letter to a clearance)
CLEARANCES (SINGLE WALL PIPE)
CANADA / USA
MODEL
A B C D E F K L
Austral
15’’/7’’
(381/178
mm)
23’’
(584 mm)
16’’
(406 mm)
18’’/11’’
(457/279
mm)
32’’
(813 mm)
25’’
(635 mm)
48’’
(1220 mm)
84’’
(213 cm)
Baltic
15’’/6’’
(381/152
mm)
12’’
(305 mm)
9’’
(229 mm)
18’’/10’’
(457/254
mm)
21’’
(533 mm)
18’’
(457mm)
48’’
(1220 mm)
84’’
(213 cm)
Legend
15’’/6’’
(381/155
mm)
12’’
(305 mm)
9’’
(229 mm)
18’’/10’’
(457/254
mm)
21’’
(533 mm)
18’’
(457 mm)
48’’
(1220 mm)
84’’
(213 cm)
Myriad
15’’/7’’
(381/178
mm)
23’’
(584 mm)
16’’
(406 mm)
18’’/11’’
(457/279
mm)
32’’
(813 mm)
25’’
(635 mm)
48’’
(1220 mm)
84’’
(213 cm)
CLEARANCES (DOUBLE WALL PIPE)
CANADA / USA
MODEL
A B C D E F K L
Austral
6’’
(152 mm)
24’’
(610 mm)
17’’
(432 mm)
10’’
(254 mm)
33’’
(838 mm)
26’’
(660 mm)
48’’
(1220 mm)
84’’
(213 cm)
Baltic
6’’
(152 mm)
12’’
(305 mm)
9’’
(229 mm)
10’’
(254 mm)
21’’
(533 mm)
18’’
(457 mm)
48’’
(1220 mm)
84’’
(213 cm)
Legend
6’’
(152 mm)
12’’
(305 mm)
9’’
(229 mm)
10’’
(254 mm)
21’’
(533 mm)
18’’
(457 mm)
48’’
(1220 mm)
84’’
(213 cm)
Myriad
6’’
(152 mm)
24’’
(610 mm)
17’’
(432 mm)
10’’
(254 mm)
33’’
(838 mm)
26’’
(665 mm)
48’’
(1220 mm)
84’’
(213 cm)
Содержание AUSTRAL NG1800
Страница 8: ...8 AUSTRAL LEGEND AND MYRIAD Ash Pan Installation...
Страница 12: ...12 FIGURE 1 3 Clearances to combustible materials and floor protection...
Страница 24: ...24 FACTORY BUILT THIMBLE...
Страница 25: ...25 BRICK THIMBLE...