 - 3 -

2.1 Training 

Before the chair is put into service, this manual must be read thoroughly 
by the caregiver(s) directly responsible for the resident’s care. 

After the chair is put into service, this manual must be read thoroughly by 
any new caregivers prior to operating or moving the chair. 

F

or the purpose of this manual, a resident’s family member who shares 

responsibility for their care is considered a caregiver and is subject to 
the same competency before being permitted by the resident’s primary 
caregiver to operate of move the chair. 

T

he primary caregiver must maintain a list of caregivers who have read this 

manual and who they have authorized to operate and move the chair. 
The resident’s primary caregiver is responsible for ensuring anyone who is 
unfamiliar with, unwilling, or unable to adhere to the safety and operating 
instructions, is not permitted to operate or move the chair. 

T

he operations of the chair must be performed by the resident’s primary 

caregiver who is responsible for seating. All The operations and adjustments 
performed should be done in a manner to ensure the overall safety, comfort 
and well-being of the resident, caregiver and third party. All operations 
and adjustments required for the resident should be determined by the 
resident’s primary caregiver who is responsible for seating. 

2.2 Application 

D

RIVE chairs are intended primarily for post-acute care residence or who 

are under the care of professional caregivers. The suitability of a DRIVE 
chair must be determined by a qualified caregiver who is familiar with 
the seating needs of the intended resident. Any other use of the chair is 
excluded from possible liability claims. 

T

he DRIVE Chair with Caster Full Tilt and Recliner s are not to be used in 

the shower. The frame and components will rust and will void the warranty. 

T

he chairs are not explosion resistant and must not be used where there 

are flammable gases or liquids present (e.g., anesthetics, volatile solvents, 
and cleaners, etc.) 

D

RIVE chairs are designed for use with specific DRIVE parts and accessories. 

The use of non-DRIVE parts or accessories with a DRIVE chair will void the 
warranty and is excluded from possible liability claims. 

D

RIVE chairs may only be used as described in this manual and with proper 

regard for recognized healthcare and workplace safety and accident 
prevention practices. 

2. SAFETY REQUIREMENTS 

Содержание CLN400-20

Страница 1: ...Full Tilt and Recliner Item CLN400 20 Distributor Rep This manual must be given to the caregiver responsible for this chair and its occupant Caregiver Before using this chair read this manual thoroug...

Страница 2: ...sident s Skin 6 2 6 Improper Use 7 2 6 1 Improper Restraint Use Risk of Serious Injury 7 2 7 Cleaning 8 2 8 Maintenance 9 2 9 Resident Specific Instructions 9 3 OPERATION AND MOVEMENT 10 3 1 Seat Tilt...

Страница 3: ...050 tel 516 998 4600 website www drivemedical com FOREWORD This document provides guidance on the safe and effective operation Information in this manual must be followed at all times Anyone involved...

Страница 4: ...or the chair used by the resident and may include the resident s family members or guardian Seat Tilt refers to changing the relative angle between the chair s seat and the chair frame or ground witho...

Страница 5: ...o ensure the overall safety comfort and well being of the resident caregiver and third party All operations and adjustments required for the resident should be determined by the resident s primary car...

Страница 6: ...visual inspection and before use These obligations apply to the chair s first use and to all subsequent uses Section 4 Inspection and Functional Testing 2 5 Hazards 2 5 1 Position of Chair Danger of...

Страница 7: ...ace to minimize the risk of tipping over 2 5 4 Total Lock Wheel Brakes Danger of Falling The special casters found on the DRIVE chair have total lock brakes which prevent the wheels from turning and s...

Страница 8: ...be required to ensure the safety of these residents during these operations 2 5 6 Unintended Movement Danger of Falling or Collision We recommend DRIVE chairs for indoor use and where there is not eno...

Страница 9: ...mmend a thigh belt be used In all cases it is the resident s primary caregiver who must take responsibility for the safety of the resident if restraints are used You should NOT have 1 Unauthorized ope...

Страница 10: ...brands include Lysol and Clorox home and Institutional use PDI healthcare setting Sani Professional food service and janitorial setting Sanitization Hand hygiene is of critical importance throughout t...

Страница 11: ...or sloped surfaces 4 Any unauthorized person Do not use lubricants that contain solvents Solvents may compromise any rubber components on the chair If necessary white food grade grease or lubricant c...

Страница 12: ...rt and assist with daily care activities WARNING Always tilt slightly before Recliner to prevent resident from sliding To Activate the Back Recline Place your LEFT hand on the top bar to assist moveme...

Страница 13: ...sters which provide upper body lateral support to the resident To Completely Remove the Wing Depress the top button 1 and pull the wing from the receptacle To Insert the Wing Insert the lower end of t...

Страница 14: ...e panel 3 9 Adjustable Seat Height To adjust the seat height Using 7 16 wrenches remove the bolts Raise or lower the front of the seat to correspond with the holes at the desired seat height Insert th...

Страница 15: ...height adjustment pins The visual inspection procedure should include the observation of any installed accessories The visual inspection should be performed by the facility or if in a private residen...

Страница 16: ...25 8 655mm I Arm pad length 14 356mm J Arm pad width 2 87 73mm k Seat depth 17 7 450mm L Back height 32 6 830mm M Width between two shoulder rest 13 330mm N Min area size between two shoulder pillow...

Страница 17: ...2 G2 Back angle 53 Recline Item No Description Spec size inch mm A1 Overall height 23 4 595mm B1 Overall length 65 2 1656mm D1 Seat height 21 6 550mm E1 Foot pad height 22 0 560mm F1 Seat angle 5 G1 B...

Страница 18: ...ROUBLESHOOTING AND REPAIR Symptom Problem Solution The chair is not Recliner or tilting or leg rest is not moving when the handle is squeezed The pin in the end of the cylinder is not being depressed...

Страница 19: ...an expression of our confidence in the mate rials and workmanship of our products and our assur ance to the consumer of years of dependable service This warranty does not cover device failure due to...

Страница 20: ...n NY 11050 Phone 516 998 4600 Fax 516 998 4601 www drivemedical com VER A 4 21 UDEM International Certification Auditing Training Centre Industry and Trade Inc Co Mutlukent Mahallesi 2073 Sokak Eski 9...

Отзывы: