Oximeter  Series

               

PULSE OXIMETER INSTRUCTION  

MANUAL

 

 

17

 

packing  case  is  intact,  open  the  package  and  remove  the 

equipment and accessories carefully. Check all materials as per 

the packing list and check for any mechanical damage.   

WARNINGS 

 

Keep the packing material out of children’s reach. Disposal 

of the packaging material should observe the applicable 

waste control regulations. 

 

The equipment might be contaminated during storage and 

transport. Before use, please verify whether the packages, 

especially the packages of the single use accessories, are 

intact. In case of any damage, do not apply it to the patient. 

3.2 Environmental Requirements 

The  operating  environment  of  the  equipment  must  meet  the 

requirements specified in this manual. 

When  the  equipment  is  moved  from  one  place  to  another, 

condensation may occur as a result of temperature or humidity 

difference.  In  this  case,  never  start  the  system  before  the 

condensation disappears. 

Warning:

 

Make  sure  that  the  operating  environment  of  the 

equipment  meets  the  specific  requirements.  Otherwise  the 

equipment  may  not  meet  the  specifications  defined  in  this  manual 

and unexpected consequences, e.g. damage to the equipment, may 

result. 

Содержание 18715

Страница 1: ...HANDY OX HAND HELD PULSE OXIMETER INSTRUCTION MANUAL Model 18715...

Страница 2: ...uction 3 1 2 Safety Information 3 1 3 Equipment symbols 8 1 4 Electromagnetism interference 9 1 5 Equipment classification 9 1 6 Accessory 10 2 General Descriptions 11 2 1 Front panel 11 2 2 Rear pane...

Страница 3: ...Series PULSE OXIMETER INSTRUCTION MANUAL 2 4 Take a measurement 19 5 Maintain and Cleaning 25 5 1 Safety Checks 26 5 2 Calibration and Verification 28 5 3 Warranty 27 APPENDIX A Specifications 30 APPE...

Страница 4: ...afe user operation of this product Warning Indicates a potential hazard or unsafe practice that if not avoided will result in death or serious injury Caution Indicates a potential hazard or unsafe pra...

Страница 5: ...onged use may cause blisters skin deterioration and discomfort When connecting this oximeter to any instrument verify proper operation before clinical use Refer to the instrument s user manual for ful...

Страница 6: ...ce to treat a patient pay special attention to data cable and check it more frequently When using the equipment with electrosurgical units ESU make sure the patient is safe Do not come into contact wi...

Страница 7: ...life the equipment as well as its accessories must be disposed of in compliance with the guidelines regulating the disposal of such products Always install or carry the equipment properly to avoid da...

Страница 8: ...ore applying SpO2 sensors Fingernail polish or artificial fingernails may cause inaccurate SpO2 readings Optical cross talk can occur when two or more sensors are located in adjoining areas It can be...

Страница 9: ...not have all of them Federal Law restricts this device to sale by or on the order of a physician 1 3 Equipment symbols Symbol s Definitions Attention Read the operator s manual carefully before using...

Страница 10: ...ome environments e g cellular phones mobile two way radios electrical appliances it is possible that high levels of such interference due to close proximity or strength of a source may result in disru...

Страница 11: ...ng to the methods of sterilization or disinfection Non sterilizable Use of Liquid surface disinfectants only According to the mode of operation continuous operation Equipment not suitable for use in t...

Страница 12: ...neral Descriptions The handheld pulse oximeter adapts 8 segment digital LED for displaying data It can display the SpO2 and pulse rate value pulse bar as well as battery status etc 2 1 Front panel Ple...

Страница 13: ...XIMETER INSTRUCTION MANUAL 12 Fig1 Front panel Instruction of figure 1 1 SpO2 SpO2 value 2 PR Pulse rate 3 Low power indicator When the power is lower than 2 4V the lamp indicated by it will be lighte...

Страница 14: ...han 2 3V 4 Alarm Indicator When technical alarm or physiological alarm occurs the lamp indicated by it will turn red 5 Power button 6 Pulse bar The pulse bar is in proportion to the Pulse volume Note...

Страница 15: ...er Batteries Installation 1 Open the battery cover Rotate the fixing screw slightly in the rear panel to the up position which is marked with and then open the cover 2 Install 2 batteries lightly as i...

Страница 16: ...ore replacing the batteries Dispose of the used batteries according to the applicable local regulations Warnings If battery fluid should get into your eyes immediately rinse with plenty of clean water...

Страница 17: ...protection Compact light weight design for simple one hand operation High brightness LED displays SpO2 pulse rate and pulse bar Visual audio alarm low battery alarm Convenient 2 AA size alkaline batt...

Страница 18: ...especially the packages of the single use accessories are intact In case of any damage do not apply it to the patient 3 2 Environmental Requirements The operating environment of the equipment must mee...

Страница 19: ...ional connector on top of the oximeter as shown in figure 3 Ensure that the sensor is firmly plugged in Fig 3 3 4 Starting or shutting off the oximeter To start the pulse oximeter 1 Press and hold the...

Страница 20: ...ulse oximeter if you suspect it is not working properly or if it is mechanically damaged Contact the carrier or our service department immediately 5 Take a measurement SpO2 measuring is a non invasive...

Страница 21: ...ximeter Note To maintain the highest degree of accuracy it is recommended that the finger and the oximeter sensor probe are kept as still as possible Description of Fig 7 SpO2 SpO2 value displayed val...

Страница 22: ...formance depends on the wavelength absorption for oxyhemoglobin and deoxyhemoglobin If there are substances absorbing the same wavelength this would induce false or low SpO2 values The following may a...

Страница 23: ...2 sensors may cause improper performance Do not use an SpO2 sensor with exposed optical components Excessive patient movement may cause inaccurate measurements Tissue damage can be caused by incorrect...

Страница 24: ...CATORS If an alarm threshold is exceeded the corresponding data area will flash If the alarm is activated by more than one physiological alarm each parameter will flash 5 1 AUDIBLE ALARM INDICATORS Au...

Страница 25: ...imeter can not search for pulse E 7 It takes too long to search pulse E 8 Pulse alarm is malfunctioning E 9 The SpO2 value is lower than the low limit E 10 The SpO2 value is higher than the high limit...

Страница 26: ...times under the normal screen to enter access to this function associated screen will be displayed Press up or down key to set the pulse beep on off 9 Maintain and Cleaning Use only the substances app...

Страница 27: ...cessories Do not allow liquid to enter the case Never use abrasive materials such as steel wool or silver polish or erosive cleaners such as acetone or acetone based cleaners 9 1 Safety Checks Before...

Страница 28: ...do not use the pulse oximeter Cleaning Your equipment should be cleaned on a regular basis If the unit is dirty the equipment should be cleaned more frequently Before cleaning the equipment consult y...

Страница 29: ...quipment in a ventilated place Disinfecting Disinfection may cause damage to the equipment and is therefore not recommended for this pulse oximeter CAUTION Never use EtO or formaldehyde for disinfecti...

Страница 30: ...lue with probes as follows Oxygen Saturation Tolerance 96 2 86 2 70 3 9 2 4 SpO2 Pulse Rate Alarm Verification a Connect SpO2 Probe to the SpO2 connector on the oximeter b Insert the operator s finger...

Страница 31: ...ontact our service department d E3 E6 E7 alarm Check the patient condition and other please contact our service department Warranty Drive warrants to the purchaser for 2 years from the date of purchas...

Страница 32: ...rt Any sign or evidence of opening the oximeter field service by non Drive personnel tampering or any kind of misuse of the oximeter shall void the warranty The oximeter is warranted for consumer use...

Страница 33: ...d 940nm 3mw nominal Pulse Rate Display range 0 254bpm Measurement range 30 235bpm Resolution 1bpm Accuracy 30 99bpm 2bpm 100 235bpm 2 Operation Environment Operating temperature 5 40 Relative humidity...

Страница 34: ...Oximeter Abbreviations A ampere bpm beats per minute C centigrade g gram kHz kilohertz MHz megahertz GHz Gigahertz h hour Hz hertz K kilo kg kilogram kPa kilopascal m meter minute M mega min minute m...

Страница 35: ...ld be at least 30 Guidance and manufacture s declaration Electromagnetic Immunity for Equipment and Systems that are not Life Supporting 61000 4 6 Radiated RF IEC 61000 4 3 3V m 80Hz to 2 5 GHz d P V1...

Страница 36: ...an electromagnetic environment in which radiated RF disturbance are controlled The customer or the user of the handheld Pulse Oximeter can help prevent electromagnetic interference by maintaining a mi...

Страница 37: ...frequency range applies NOTE2 These guidelines may not apply in all situations Electromagnetic interference is affected by absorption and reflection from structures objects and people DRIVE MEDICAL 99...

Отзывы: