background image

Page 6

For technical questions, please call 1-800-444-3353.

Item 61626 

        

SAFET

y

Op
ERA
TION

M

AINTENAN

c

E

SETU
p

Grounding

TO pREVENT ELEcTRIc SHOcK AND DEATH FROM 

INcORREcT GROUNDING WIRE cONNEcTION: 

check with a qualified electrician if you are in doubt as to whether the outlet is properly 

grounded.  Do not modify the power cord plug provided with the tool.  Never remove the 

grounding prong from the plug.  Do not use the tool if the power cord or plug is damaged.  If damaged, have 

it repaired by a service facility before use.  If the plug will not fit the outlet, have a proper outlet installed by 

a qualified electrician.

Grounded Tools: Tools with Three prong plugs

 

3-prong plug and Outlet

1.  Tools marked with “Grounding Required” have 

a three wire cord and three prong grounding 

plug.  The plug must be connected to a properly 

grounded outlet.  If the tool should electrically 

malfunction or break down, grounding provides 

a low resistance path to carry electricity away 

from the user, reducing the risk of electric shock.  

(See 3-prong plug and Outlet.)

2.  The grounding prong in the plug is connected 

through the green wire inside the cord to the 

grounding system in the tool.  The green wire 

in the cord must be the only wire connected to 

the tool’s grounding system and must never 

be attached to an electrically “live” terminal.  

(See 3-prong plug and Outlet.)

3.  The tool must be plugged into an appropriate outlet, 

properly installed and grounded in accordance 

with all codes and ordinances.  The plug and outlet 

should look like those in the preceding illustration.   

(See 3-prong plug and Outlet.)

Double Insulated Tools: Tools with Two prong plugs

 

Outlets for 2-prong plug

1.  Tools marked “Double Insulated” do not 

require grounding.  They have a special 

double insulation system which satisfies 

OSHA requirements and complies with 

the applicable standards of Underwriters 

Laboratories, Inc., the Canadian Standard 

Association, and the National Electrical Code.

2.  Double insulated tools may be used in either of the 

120 volt outlets shown in the preceding illustration.

   

(See Outlets for 2-prong plug.)

Содержание 61626

Страница 1: ......

Страница 2: ...on which if not avoided could result in minor or moderate injury Addresses practices not related to personal injury IMpORTANT SAFETy INFORMATION General power Tool Safety Warnings Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The term power...

Страница 3: ...f position before connecting to power source picking up or carrying the tool Carrying power tools with your finger on the Trigger or energizing power tools that have the Trigger on invites accidents 4 Remove any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury 5 Do not overreach Keep proper f...

Страница 4: ...ntrol 8 When using a handheld power tool maintain a firm grip on the tool with both hands to resist starting torque 9 Do not depress the spindle lock when starting or during operation 10 Do not leave the tool unattended when it is plugged into an electrical outlet Turn off the tool and unplug it from its electrical outlet before leaving 11 This product is not a toy Keep it out of reach of children...

Страница 5: ...ion to the hand past hand injuries nervous system disorders diabetes or Raynaud s Disease should not use this tool If you feel any symptoms related to vibration such as tingling numbness and white or blue fingers seek medical advice as soon as possible 2 Do not smoke during use Nicotine reduces the blood supply to the hands and fingers increasing the risk of vibration related injury 3 Wear suitabl...

Страница 6: ... to carry electricity away from the user reducing the risk of electric shock See 3 prong plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to an electrically live terminal See 3 prong plug and Ou...

Страница 7: ...rked with the suffix W A W in Canada to indicate it is acceptable for outdoor use 7 Make sure the extension cord is properly wired and in good electrical condition Always replace a damaged extension cord or have it repaired by a qualified electrician before using it 8 Protect the extension cords from sharp objects excessive heat and damp or wet areas TABLE A REcOMMENDED MINIMUM WIRE GAUGE FOR EXTE...

Страница 8: ... Load Collet 1 4 Accessories Included Trim Guide Small Wrench Large Wrench 3114052 Setup Before Use Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product Functions Router Switch Fence Fence Bracket Wing Nut Trim Guide Lock Knob Base Knob Base Edge Knob Attachment Knob ...

Страница 9: ...e some resistance so make sure that it goes in all the way 6 While holding the Small Wrench over the Spindle tighten the Collet Nut with the Large Wrench Adjusting cutting Depth Set the depth of cut using the scale marked on the side of the Router 1 Install the router bit as previously described 2 Loosen the Base Knob Slide the Base downward so the router bit is retracted within the Base 3 Place t...

Страница 10: ...allel the edge of the workpiece 1 Clamp a suitable straight board across the workpiece parallel to the desired location of the cut 2 Install the Fence Asm with the Fence facing outward and up as shown in Figure B 3 After measuring the proper distance from the router bit to the temporary guide tighten the Fence using the Attachment Knob and Wing Nut 4 Make a test cut on a piece of scrap material to...

Страница 11: ...fe route to reach the work area without creating a tripping hazard or exposing the power cord to possible damage The power cord must reach the work area with enough extra length to allow free movement while working 3 Secure loose workpieces using a vise or clamps not included to prevent movement while working 4 There must not be objects such as utility lines nearby that will present a hazard while...

Страница 12: ...E inspect the general condition of the tool Check for loose hardware misalignment or binding of moving parts damaged cord electrical wiring cracked or broken parts and any other condition that may affect its safe operation 2 AFTER USE wipe external surfaces of the tool with clean cloth 3 Periodically wear ANSI approved safety goggles and NIOSH approved breathing protection and blow dust out of the...

Страница 13: ...its length and load See Extension Cords in Grounding section on page 6 Performance decreases over time 1 Carbon brushes worn or damaged 2 Router bit dull or damaged 1 Have qualified technician replace brushes 2 Use sharp bits Replace as needed Excessive noise or rattling Internal damage or wear Carbon brushes or bearings for example Have technician service tool Overheating 1 Forcing tool to work t...

Страница 14: ...CT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO parts List Record product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts part Description 1 Power Cord 2 Cord Protector ...

Страница 15: ...Page 15 For technical questions please call 1 800 444 3353 Item 61626 SAFETy OpERATION MAINTENANcE SETUp Assembly Diagram ...

Страница 16: ... the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and...

Отзывы: