MACHINE TRANSPORT AND STORAGE
SECTION 3
Page 7
DRESSTA
OM560C99/1E
MACHINE STORAGE
FUEL PREP 1000
NALCO CHEMICAL COMPANY
2901 BUTTERFIELD ROAD
OAK BROOK, ILLINOIS 60521, USA
or Machine Distributor
WARNING: Corrosion inhibitors are volatile and flammable. Use them only in a
well-ventilated area. Keep flames and sparks away. DO NOT SMOKE. Store a
container in a cool, well-ventilated place.
CAUTION: Avoid prolonged exposure to volatile corrosion inhibitors because
eye and skin irritation may occur.
10. It is recommended to use volatile corrosion inhibitor ("VCI") in the fuel tank. The "VCI" provides
corrosion protection by contact with the metal, and in a closed system, the vapors provide
sufficient protection for areas that are not in contact with the oil. When using VCI per HMS B00-
0006 pour 120 of volatile corrosion inhibitor for each 100 l of total fuel capacity. The "VCI" may
be purchased from:
NOX RUST VCI #105 OIL
DAUBERT CHEMICAL COMPANY
1200 JORIES BLVD.
OAK BROOK, ILLINOIS 60521, USA
or Machine Distributor
11. Deaerate the fuel system . Refer to FUEL SYSTEM Section 5.
12. Start the engine and run idle at 1400 to 1600 rpm for 4 minutes and then stop the engine.
13. Lubricate all points of the machine as outlined in the "SERVICE GUIDE" in Section 5.
IMPORTANT:
Be sure to oil or grease all linkage connections, joints, nuts, pins, shafts, and
bushings not covered in the "SERVICE GUIDE".
14. Drain the engine oil, replace the engine oil filters and fill them with proper grade of oil. Refer to
ENGINE Section 5.
15. Add 15 ml VCI for each liter of engine oil to the crankcase. (example: if the total capacity of the
crankcase is 10 l add 150 ml VCI).
16. Start the engine and run it idle at 1400 to 1600 rpm for 30 seconds and then stop the engine.
17. Remove the air precleaner.
18. Seal all external openings (i.e. engine exhaust outlet, filler caps, breathers, etc.) with tape wide
enough to cover the opening, regardless of its size.
NOTE:
When sealing with tape, be sure to extend tape approximately one inch (25 mm) beyond
opening to insure a good seal.
19. Pour 120 ml VCI to the intake manifold to prevent corrosion of the space between piston and
bottom part of the head.
20. It is recommended to pour 390 ml VCI type 1 oil per HMS B00-0006 (KDC Standard) to the
hydraulic reservoir.
21. Remove the batteries and place them on wooden skids. Then, store them in a cool, clean, dry,
well-ventilated place away from the areas provided for storing or dispensing fuel and oil, not
near any heat source and preferably where the temperature range is between 0° to +21 °C . Be
sure the batteries are fully charged.
Содержание 560C
Страница 1: ...OM560C99 1E OPERATOR S MANUAL 560C SERIAL NUMBERS 15001 AND UP ...
Страница 3: ......
Страница 5: ......
Страница 7: ......
Страница 10: ...SECTION 1 INTRODUCTION ...
Страница 11: ...INTRODUCTION SECTION 1 DRESSTA OM560C99 1E SECTION CONTENTS 1 1 Introduction 3 1 2 Serial Numbers 4 ...
Страница 12: ......
Страница 16: ...SECTION 2 SAFETY PRECAUTIONS ...
Страница 18: ......
Страница 32: ...SECTION 3 MACHINE TRANSPORT AND STORAGE ...
Страница 34: ......
Страница 42: ...SECTION 4 OPERATING ...
Страница 43: ......
Страница 45: ......
Страница 49: ...SECTION 4 OPERATING Page 6 OM560C99 1E DRESSTA UNIVERSAL SYMBOLS FOR INSTRUMENTS AND CONTROLS ...
Страница 88: ...SECTION 5 MAINTENANCE ...
Страница 141: ...SECTION 6 SPECIFICATIONS ...
Страница 143: ......
Страница 151: ...SECTION 6 SPECIFICATIONS Page 10 OM560C99 1E DRESSTA 6 7 WIRING DIAGRAM Fig 6 5 Wiring Diagram ...
Страница 154: ...SPECIFICATIONS SECTION 6 Page 13 DRESSTA OM560C99 1E WIRING DIAGRAM Fig 6 6 Wiring Diagram Of Cab ...