background image

Installation

2-8

April 2003

Part No. 917404-001 Rev. B

1.

 

Turn power 

Off

 to the site controller. 

2.

 

Place a wrist strap, (Wayne part number 916962, 3M Charge Guard 2213, or equivalent), on your

wrist and clip the grounding end to the chassis of the power supply in the site controller. 

3.

 

If there is a PIB/Plus board in slot 6, remove it.

4.

 

Install the HyperPIB board in slot 2 (remove the 2400/Plus CPU board on this slot if there is one)

of the site controller. Refer to Figure 2-1. Place the HyperPIB board with the component side

facing toward the power supply. 

5.

 

Check the site controller cabinet for loose tools or parts.

6.

 

Remove the grounding end of the wrist strap from the power supply and close the cabinet door. 

7.

 

Turn power 

On

 to the site controller. 

8.

 

To check the HyperPIB software version, enter mode 90 and submode 08 on the 2400 console,

then press the PRNT/ENTR key. The console screen displays the HyperPIB version in the

following format: VVWWYY00, where VV is the HyperPIB version number, WW and YY the

week and year when the software is released. 

Note: If the HyperPIB version does not appear on the console screen, the HyperPIB board is not

communicating with the 2400 console. If the checksum does not equal zero, the HyperPIB firmware

or hardware is not operating correctly and must be replaced. 

9.

 

To check the HyperPIB software checksum, enter mode 90 and submode 07 on the 2400 console,

then press the PRNT/ENTR key. The console screen displays the software checksum. The

checksum should equal zeroes if a production release version of code is present.

10.

 

Turn power to the site controller 

Off.

11.

 

Remove the six screws securing the metal plate to the hinge side of the site controller. Discard the

metal plate.  Install the new side panel (part number 850258-04). 

12.

 

Connect the 10-pin AMP connector end of cable, part number 887902-001, to J1 on the

HyperPIB board, then connect the 25-pin DB connector end to slot J1 on the side panel of the site

controller using the screw assembly #5010303. 

13.

 

Connect the 10-pin AMP connector end of cable, part number 887902-001, to J2 on the

HyperPIB board, then connect the 25-pin DB connector end to slot J2 on the side panel of the site

controller using the screw assembly #5010303.

Содержание Wayne HyperPIB Series

Страница 1: ...INSTALLATION Wayne Hyper Peripheral Interface Board HyperPIB ...

Страница 2: ......

Страница 3: ...Wayne HyperPIB Peripheral Interface Board Installation Manual ...

Страница 4: ...uced stored in a retrieval system or transmitted in any form or by any means except as permitted by such license Translation of this material to another language without express written permission of Dresser Industries is prohibited The information in this publication is for informational use only and is subject to change without notice The contents should not be construed as a commitment by Dress...

Страница 5: ...on 2 Installation 2 1 Introduction 2 3 2 2 Unpacking And Inspection 2 3 2 3 Returning Damaged Components 2 4 2 4 HyperPIB Installation 2 4 2 4 1 Required Equipment 2 4 2 4 2 HyperPIB Board Configuration 2 5 2 4 2 1 Jumpers and Switches 2 5 2 4 2 2 Connectors 2 7 2 4 2 3 LEDs 2 7 2 4 2 4 Pin Definitions 2 7 2 4 3 HyperPIB Board And RS 232 Cable Installation 2 7 ...

Страница 6: ...nd Liability FCC Warning List Of Figures Figure 2 1 HyperPIB Board Jumper Settings 2 6 Figure 2 1 HyperPIB Board and RS 232 Installation 2 8 List Of Tables Table 1 1 Required Equipment 1 2 Table 2 1 HyperPIB Connectors 2 5 Table 2 2 HyperPIB LEDs 2 6 Table 2 3 RS 232 DB 25 Pin Definitions 2 6 ...

Страница 7: ...nd Programming Wayne 2400 Plus Management Control System part number 917434 1 2 HyperPIB Overview Installing the HyperPIB board part number 881415 xxx in the site controller allows the 2400 Plus system to communicate with auxiliary controllers AC Auxiliary controllers are then able to operate in place of the Wayne 2400 Control console when controlling Wayne dispensers Auxiliary controllers such as...

Страница 8: ...Installation 1 2 April 2003 Part No 917404 001 Rev B Table 1 1 Required Equipment Part Number Description 1 916962 Phillips Head Screwdriver Anti Static Wrist Strap ...

Страница 9: ...ll of lading 4 Retain cartons suspected of damage for future claim purposes CAUTION To remove electronic components from static packages you must wear an anti static wrist strap part number 916962 The wrist strap must be securely attached to an earth grounding point to prevent possible damage from static electricity 5 Remove all equipment from the shipping cartons and carefully inspect for damage ...

Страница 10: ...ene foam or bubble pack to ensure the component is firmly packed 2 Include a Return Parts Tag with the defective component describing the particular problem with the part 3 Make sure that adequate insurance is provided when returning parts to the factory WARNING If the parts or components arrive at our factory in a damaged condition and it is determined that the damage is a direct result of inadeq...

Страница 11: ...male Screwlock Kit 2 887902 001 RS 232 Interface Cable 2 881415 xxx HyperPIB PCB Board 1 2 4 2 HyperPIB Board Configuration 2 4 2 1 Jumpers and Switches Set the AC baud rate s to match the AC s on site Also verify DIP switch and other jumper settings on the board to match the ones stated below ...

Страница 12: ...8400 Pins 3 4 19200 Pins 5 6 9600 Pins 7 8 4800 Pins 9 10 2400 Pins 11 12 1200 Pins 1 2 38400 Pins 3 4 19200 Pins 5 6 9600 Pins 7 8 4800 Pins 9 10 2400 Pins 11 12 1200 JP10 JP11 Pump Console B Baud Rate Pins 1 2 19200 Pins 3 4 9600 Default Pins 5 6 4800 JP12 Pins 1 2 19200 Pins 3 4 9600 Default Pins 5 6 4800 Pump Console A Baud Rate JP13 Secondary Auxillary Controller Board Rate Settings Primary A...

Страница 13: ...2 Receiving data from Primary AC CR13 Pump link B active CR14 Pump link A active CR15 Console active 2 4 2 4 Pin Definitions Table 2 3 RS 232 DB 25 Pin Definitions PIN Number Signal Direction Definition 1 FG Frame Ground 2 TX Transmit 3 RX Receive 4 RTS Request To Send 5 CTS Clear To Send 7 SG Signal Ground 8 CD Carrier Detect 20 DTR Data Terminal Ready 2 4 3 HyperPIB Board And RS 232 Cable Instal...

Страница 14: ...eek and year when the software is released Note If the HyperPIB version does not appear on the console screen the HyperPIB board is not communicating with the 2400 console If the checksum does not equal zero the HyperPIB firmware or hardware is not operating correctly and must be replaced 9 To check the HyperPIB software checksum enter mode 90 and submode 07 on the 2400 console then press the PRNT...

Страница 15: ...OTE Older site controller cabinets may have knockout mounting holes instead of a removable plate In this case connect cables in the uppermost knockout mounting holes Figure 2 2 HyperPIB Board And RS 232 Installation 14 Restore power to the site controller ...

Страница 16: ...tt Joe Velasquez and Wang Zhao for their technical assistance and review This manual was produced using Microsoft Word for Windows on a Compaq Deskpro PC Page design uses a 1 column format set at 10 12 using Times New Roman and Arial Mechanicals were printed on a HP LaserJet 5000 Art was produced using Adobe Illustrator ...

Страница 17: ......

Страница 18: ...uipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Dresser Wayne Dresser Inc 3814 Jar...

Отзывы: