background image

Customer Service Tel: 0845 130 5522

Customer Service Fax: 0845 130 0622

Technical Helpline Tel: 0845 130 7722

Website: www.draytoncontrols.co.uk

Email: [email protected]

090-728 ISSD

HTS3 Cylinder

Thermostat

Installation instructions

Technical Data

Setting Range

50° – 80°C

Differential

8°C approx.

Switch rating

3 (1) A 230V ac

Switch type

SPDT

Earth

Double insulated

– not required

Connections

C – common

1 – call

2 – satisfied

Fixing

Plastic-coated spring wire

with hook and eyelet.

Conforms to the essential

requirements of the following directives:

2004/108/EC – Electromagnetic compatibility

Directive

2006/95/EC – Low Voltage Directive

Cylinder thermostats

Make

Model

Common Call Satisfied

HTS 3

C

1

2

Lifestyle

HTS 2

R

B

Y

Danfoss

Randall

AT (CN4)

1

2

3

Drayton

CS 1/CS 2

1

2

3

Honeywell L641A

C

1

2

Landis

& Gyr

RAM 1

1

2

3

Potterton

Myson

PTT 1

L

H

C

Sunvic

1452/

SA2451

3

1

2

Sopac

SAY

C

1

2

Smiths

SCT 1

1

2

3

Tower

CS 1

R

B

Y

Barlo

CT 1

R

B

Y

Pollution Degree       

2

 

Ball pressure 

Test Temperature

  

110ºC

Rated impulse

voltage

2.5kV

2011/65/EU   – Restriction of the Use of Certain

Hazardous Substances (RoHS)

Energy Class

I = 1% (Acc. EU 

811/2013, 812/2013, 

813/2013, 814/2013)