Sample Rate Converter 1
SOURCE

Three inputs are conveniently located on the front panel for easy access - 

SPDIF

TOSLINK 

and

 AES.

Toggle through the “Source” switch to select the desired input. A lock LED is provided - when lit a
strong signal is being recieved by that input source and the M-Clock Plus is “locked on”. If the LED
is off the input source may be missing, weak or unstable - in this case the source of the signal
should be located and improved.

WORD LENGTH

A switch provides either 16 or 24 Bit operation.

Sample Rate Converter 2
SOURCE

Toggle through the “Source” switch to select the
desired input on the S.R.C.2 outputs on the rear
panel.  A lock LED is provided on the front - when lit
a strong signal is being recieved by that input
source and the M-Clock Plus is “locked on”. If the
LED is off the input source may be missing, weak
or unstable - in this case the source of the signal
should be located and improved.

WORD LENGTH

As above.

CHAPTER 2

DISPLAY

A Blue/White LCD display wth four switchable modes of operation: When reading from it’s own
internal clock the M-Clock Plus will display a sample rate of 44.1kHz.

 ,

 when reading from an

EXT

ernal source it displays either 

FREQ

±PPM

 or 

±%

 depending on  the 

mode

 set.

The mode that is selected during power down is saved for the next session.
The display accuracy is 2ppm at all sample rates up to 192kHz, or 0.1Hz increments @
48KHz sample rate

.

grade 1 stability master clock generator as the equipment
using the word clock outputs from the DMS-5.
In addition, if any equipment in the studio suffers jitter at its
output these sample rate converters may be used to de-jitter
and re-clock the signals before further transmission.
The M-clock Plus provides a wide range of sample rates
from 44.1k upto 192k, all set using the front panel switching.
Each sample rate converter input is fed simultaneously to
AES/EBU, SPDIF and TOSLINK outputs solving any
connectivity problems and allowing signal distribution.

The Drawmer M-Clock Plus supplies ten word clock outputs,
as well as two simultaneous outputs of S/PDIF and AES/
EBU allowing you to synchronize your digital workstation, A/D
converter, digital mixer and a host of other digital audio
equipment through one stable and very accurate unit.
Certain equipment in the studio may not have word clock
inputs which has in the past caused synchronisation
problems, using the DMS-5 M-CLOCK Plus these digital audio
sources may be synched to the same ultra low jitter AES

Содержание M-Clock Plus DMS-5

Страница 1: ...ideration Radio Frequencies Statement Chapter 1 Introduction Introduction Installation Audio Connection Guide Chapter 2 Control Description Multiple Sample Rate Converter Master Clock Generator Chapter 3 General Information If a fault develops Contacting Drawmer Specification Block Diagram 2 2 2 3 4 4 6 7 8 8 8 9 ...

Страница 2: ... last so the above limitations may not apply to you This warranty gives you specific legal rights You may have additional rights that vary from state to state and country to country For the USA FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules ...

Страница 3: ...1 8 9 6 Display Mode Switch to control the Mode of Display 6 from FREQ PPM or 7 Master Clock Generator Output sample rate selector with switch for EXT source also 13 8 Wordclock Outputs 9 10 Two extra wordclock outputs conveniently placed for easy access 9 2 INTRODUCTION The M Clock Plus is a high stability master clock generator offering clock rates from 44 1 to 192kHz coupled to two sample rate ...

Страница 4: ...d where it may be exposed to high levels of disturbance such as found close to a TV or radio transmitter it is suggested that the screen of the data cable be connected to the chassis connection on the XLR type connector rather than to pin 1 If ground loop problems are encountered never disconnect the mains ground but instead try disconnecting the signal screen on one end of each cable connecting t...

Страница 5: ...5 TYPICAL CONNECTION GUIDE M Clock Plus Generates Clock ...

Страница 6: ...z when reading from an EXTernal source it displays either FREQ PPM or depending on the mode set The mode that is selected during power down is saved for the next session The display accuracy is 2ppm at all sample rates up to 192kHz or 0 1Hz increments 48KHz sample rate grade 1 stability master clock generator as the equipment using the word clock outputs from the DMS 5 In addition if any equipment...

Страница 7: ... 2 88 2 96 192KHz MASTER CLOCK GENERATOR SAMPLE RATE The outgoing sample rate for all outputs of the DMS 5 can be set using the two sample rate switches the left moving down rate and the right moving up with a corresponding LED being lit to show the current sample rate The DSM 5 generates six Ultra Low Jitter sample rates 44 1k 48k 88 2k 96k 176 4k and 192k all stable to 1ppm and in addition can a...

Страница 8: ...For warranty service please call Drawmer Electronics Ltd or their nearest authorised service facility giving full details of the difficulty A list of all main dealers can be found on the Drawmer webpages On receipt of this information service or shipping instructions will be forwarded to you No equipment should be returned under the warranty without prior consent from Drawmer or their authorised r...

Страница 9: ...9 BLOCK DIAGRAM Ref 1v01 A 11 02 08 ...

Страница 10: ...10 ...

Отзывы: