background image

3

DRAWMER

DRAWMER

DRAWMER

DRAWMER

DRAWMER

M-Cloc

M-Cloc

M-Cloc

M-Cloc

M-Clock 

Plus

Plus

Plus

Plus

Plus

DMS-5

AES GRADE 1 MASTER CLOCK AND DUAL SAMPLE RATE CONVERTER

S.R.C.1 Inputs:

One each of 

S/PDIF

TOSLINK 

or

 AES

conveniently located for easy access.

1

3

4

5

7

14

12

11

13

10

15

1

S.R.C.1 Source:

Switch to select one of the three the
S.R.C.1 Input Sources  

1

 . With 

lock

 led.

2

S.R.C.1 Word Length:

Switch to select S.R.C.1 Word Length of

16

 or 

24 Bit.

3

S.R.C.2 Source:

Switch to select one of the three the
S.R.C.2 Input Sources 

11

 . With lock led.

4

S.R.C.2 Word Length:

Switch to select S.R.C.1 Word Length of

16

 or 

24 Bit

.

5

Display:

Blue/White liquid crystal display with three
switchable modes of operation.

6

S.R.C.1 Outputs:

One each of 

S/PDIF

TOSLINK 

or

 AES

symultaneous outputs.

10

S.R.C.2 Inputs:

One each of 

S/PDIF

TOSLINK 

or

 AES

selected via  

4

 .

11

S.R.C.2 Outputs:

One each of 

S/PDIF

TOSLINK 

or

 AES

symultaneous outputs.

12

Wordclock Inputs:

Inputs in both standard 

wordclock

(BNC)

 and 

AES 11

 (XLR) upto 192kHz.

13

4x AES 11 XLR & SPDIF Outputs:

outputs to the 

AES 11

 standard

(Also called 

DARS, Blank Frame

).

14

8x BMC Clock Outputs:

Buffered 

BNC

 wordclock outputs with

33 Ohms impedance.

15

CHAPTER 1

8

9

6

Display Mode:

Switch to control the Mode of Display 

 6

from 

FREQ. +/-PPM or +/-%.

7

Master Clock Generator:

Output sample rate selector with switch
for 

EXT

 source also  

13

 .

8

Wordclock Outputs 9/10:

Two extra 

wordclock

 outputs

conveniently placed for easy access.

9

2

INTRODUCTION

The M-Clock Plus is a high stability master clock generator offering
clock rates from 44.1 to 192kHz, coupled to two sample rate
converters, which allow material to be re-sampled and syncronised
to the selected high precision clock.

In addition to the internal clocks, M-Clock Plus can sync to either
external word clock or clocks from AES/EBU signals. Precision
clock frequency measurement and display indicates the exact
frequency of the selected clock, whether internal or external, to an
accuracy of 2ppm.

Features:

M-Clock Plus has an external word clock input and an AES11 input which retrieves the clock from an AES

audio signal.

Each sample rate converter has selectable AES, SPDIF or TOSLINK inputs, with simultaneous AES, SPDIF

and TOSLINK outputs. This allows many possibilities for format conversion as well as sample rate conversion.

Sample rate converter #2 has inputs on the front panel for easy access.

User selectable word length of 16 or 24 bits with automatic dither generation -  particularly valuable for 16 bit

word lengths at low signal levels.

10 word clock outputs - 8 at the rear and 2 at the front for easy access.

Содержание M-Clock Plus DMS-5

Страница 1: ...ideration Radio Frequencies Statement Chapter 1 Introduction Introduction Installation Audio Connection Guide Chapter 2 Control Description Multiple Sample Rate Converter Master Clock Generator Chapter 3 General Information If a fault develops Contacting Drawmer Specification Block Diagram 2 2 2 3 4 4 6 7 8 8 8 9 ...

Страница 2: ... last so the above limitations may not apply to you This warranty gives you specific legal rights You may have additional rights that vary from state to state and country to country For the USA FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules ...

Страница 3: ...1 8 9 6 Display Mode Switch to control the Mode of Display 6 from FREQ PPM or 7 Master Clock Generator Output sample rate selector with switch for EXT source also 13 8 Wordclock Outputs 9 10 Two extra wordclock outputs conveniently placed for easy access 9 2 INTRODUCTION The M Clock Plus is a high stability master clock generator offering clock rates from 44 1 to 192kHz coupled to two sample rate ...

Страница 4: ...d where it may be exposed to high levels of disturbance such as found close to a TV or radio transmitter it is suggested that the screen of the data cable be connected to the chassis connection on the XLR type connector rather than to pin 1 If ground loop problems are encountered never disconnect the mains ground but instead try disconnecting the signal screen on one end of each cable connecting t...

Страница 5: ...5 TYPICAL CONNECTION GUIDE M Clock Plus Generates Clock ...

Страница 6: ...z when reading from an EXTernal source it displays either FREQ PPM or depending on the mode set The mode that is selected during power down is saved for the next session The display accuracy is 2ppm at all sample rates up to 192kHz or 0 1Hz increments 48KHz sample rate grade 1 stability master clock generator as the equipment using the word clock outputs from the DMS 5 In addition if any equipment...

Страница 7: ... 2 88 2 96 192KHz MASTER CLOCK GENERATOR SAMPLE RATE The outgoing sample rate for all outputs of the DMS 5 can be set using the two sample rate switches the left moving down rate and the right moving up with a corresponding LED being lit to show the current sample rate The DSM 5 generates six Ultra Low Jitter sample rates 44 1k 48k 88 2k 96k 176 4k and 192k all stable to 1ppm and in addition can a...

Страница 8: ...For warranty service please call Drawmer Electronics Ltd or their nearest authorised service facility giving full details of the difficulty A list of all main dealers can be found on the Drawmer webpages On receipt of this information service or shipping instructions will be forwarded to you No equipment should be returned under the warranty without prior consent from Drawmer or their authorised r...

Страница 9: ...9 BLOCK DIAGRAM Ref 1v01 A 11 02 08 ...

Страница 10: ...10 ...

Отзывы: