background image

page 8 of 10

Dual Roller FlexShade

®

 NEXD

Section 8 -

 Bead Chain Limits and Safety Device Installation

Attaching Stop Balls

1. 

Set upper and lower travel limits by installing stop balls to bead chain 

(crimp closed using pliers)

 

(Fig. 9-A)

.

P-Clip Cord Tension Device

Please Note:

 Draper

®

 Bead Chain Clutch-Operated shades that do not comply with WMCA/ANSI Standard A100.1-2012 

come with a P-Clip cord tension device pre-attached to bead chain 

(Fig. 9-B)

. This device must be attached to wall, 

jamb, or sill so that bead chain is held taut enough that children cannot pull it away from wall or fit their head into loop.

Spring-Loaded Cord Tension Device

If Draper Clutch FlexShade complies with WMCA/ANSI Standard A100.1-2018, a Spring-Loaded Cord Tension Device 

comes installed on bead chain 

(Fig. 9-C)

. An approved permanent warning label and approved mechanical fasteners 

(wood 

screws)

 are included. Device is designed so that children cannot pull bead chain away from wall or fit their head into loop. 

(See safety note on page 2)

. For more information, visit 

www.draperinc.com/WindowShades/WCMAcompliance.asp

.

1. 

Install cord tension device to wall, jamb, or sill. 

2. 

Pull tensioner down so that bead chain is held taut and use mounting hardware to keep it taut. 

Please Note:

 Bead chain should be taut enough to move smoothly through device. However, overtightening screws will 

damage Spring-Loaded Tension Device.

Section 7 -

 Attaching Fascia

A.

Position fascia flush to edge of bracket  
and/or butted to endcap cover.

B.

Snap firmly  into place.

Please Note:

 Fascia should be 

installed top to bottom, with the 

bottom edge clicking/snapping 

into position.

A

Fascia is not 

fully seated until 

it clicks into place 

on both ends. 

!

B

CLIC

K

!

A

B

CLICK

!

   NEX

D Clu

tch

  Endc

ap

   N

EXD

 Idl

er

  En

dca

p

Ensure that fascia engages 

with the metal portion 

of the endcap.

!

Figure 8-A

Figure 8-B

Chain Limits

Chain Tension Device

Figure 9-A

1. Attach 

    stop balls.

2. Crimp 

    closed

    with 

    pliers.

Sill

Mount

Jamb

Mount

Tensioner

P-Clip

Figure 9-B

P-Clip

Figure 9-C

STEP 1

STEP 2

Clicks into place.

Insert 

fascia.

SIDE 

VIEW

Содержание Dual Roller FlexShade NEXD

Страница 1: ...eceived the proper shades and parts Controls may be shipped separately or in same carton as shades 2 Open cartons lengthwise taking care not to cut into cardboard shipping container 3 Before mounting shades verify measurements on label provided with shade and ensure unit is installed at correct width 4 All endcaps fascia headboxes and other hardware must be installed level Shades must be level and...

Страница 2: ...nd normal operation Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury 10 Operation of shade should be performed only by authorized and qualified personnel who have been trained in the safe and effective operation of the shade and understand its safety features 11 The safety features of the shade should never be disabled bypassed or overridden The ...

Страница 3: ...ote Installer is responsible for selecting mounting hardware appropriate for site conditions please note Endcaps must be fastened securely to mounting surface and cannot move from side to side If changes differences or measurement errors occur on site adjust product by utilizing slotted holes in the endcap A to adjust for zero gap between the fascia and endcap covers Once these adjustments are mad...

Страница 4: ...adbox using appropriate fasteners for surface Section 2 Pocket Headbox Installation PLEASE NOTE Installer must provide adequate clearance for removal of Roller Assembly during installation and maintenance PLEASE NOTE Headbox must be mounted directly to ceiling or to a continuous blocking that is secured to building structure OPTIONAL VENT HOLES POCKET MOUNTING HOLES ENDCAP MOUNTING HOLES Figure 3 ...

Страница 5: ...ilding structure 1 Place endcaps into top back cover piece of ceiling wall headbox 2 Using pre drilled holes in endcaps mark headbox for drilling 3 Drill holes in back wall mount or top ceiling mount of top back cover piece 4 Attach endcaps and top back cover piece to wall or ceiling using mounting hardware appropriate for site conditions Next mount roller assemblies Section 4 IDLER ENDCAP COVER B...

Страница 6: ...tion Do not allow shade roller to become exposed by lowering shade fabric too far Be sure to use stop balls provided by Draper to set up and down travel limits Stop balls by others may be too small and become lodged in clutch Please Note If shade fabric is tracking to one side see Field Adjustments Page 2 Tube indentation must be aligned with the FLAT side of the clutch sprocket OPERATOR CLUTCH EN...

Страница 7: ...Hex Wrench Fig 6 C available upon request when ordering shade Section 6 Safety Brackets PLEASE NOTE Under certain extreme circumstances the Idler Endcap of the FlexShade Dual Roller NEXD may fail due to the limitations of the detents designed to hold the shade roller pins in place This kit contains necessary brackets to prevent shades from disengaging with the idler endcap and falling REMEMBER For...

Страница 8: ...ot pull bead chain away from wall or fit their head into loop See safety note on page 2 For more information visit www draperinc com WindowShades WCMAcompliance asp 1 Install cord tension device to wall jamb or sill 2 Pull tensioner down so that bead chain is held taut and use mounting hardware to keep it taut Please Note Bead chain should be taut enough to move smoothly through device However ove...

Страница 9: ...surement 1 38mm ROLLER TUBE CUT LENGTH FABRIC CUT WIDTH 2 51mm HEM BAR CUT LENGTH SHADE HEIGHT When measuring shade height remember to include Endcaps Fascia HEM BAR Small Staggered Dual Fascia with Top Back Cover 3 87mm 2 67mm 5 129mm 1 33mm 1 30mm 22mm 6 176mm 3 76mm 1 46mm 1 33mm 1 43mm MAXIMUM BUNDLE DIAMETER 3 76mm 3 87mm 2 67mm 5 130mm 1 33mm 1 30mm 22mm 7 178mm 3 76mm 1 46mm 1 33mm 1 43mm M...

Страница 10: ... FABRIC CUT WIDTH 2 51mm HEM BAR CUT LENGTH SHADE HEIGHT When measuring shade height remember to include Endcaps Fascia HEM BAR Large Staggered Dual Fascia with Top Back Cover 7 200mm 7 200mm 2 57mm 1 41mm 1 38mm 6 176mm 4 117mm 2 51mm 2 67mm 3 79mm 1 38mm 5 140mm MAX BUNDLE DIAMETER 3 75 95mm MAX BUNDLE DIAMETER 4 102mm 7 200mm 7 202mm 2 57mm 1 41mm 1 38mm 7 178mm 4 117mm 2 51mm 2 67mm 3 79mm 1 3...