background image

PLEASE READ -

 Safety Information

 WARNING   

Improper installation and use of the AeroLift 100 / 150 Projector Lift can result in serious injury or death. Primarily, injuries can occur when the unit falls due to 

imprecise installation, mishandling of the unit during installation or installation on an insufficient wall or ceiling structure. Please use extreme care.
When using an electrical mounting system, basic precautions should always be followed, including the following: Please read the following installation guide-

lines thoroughly before using this mounting system. Failure to do so may cause product to fall or otherwise fail and could result in serious injury.
Please Note: An appropriate disconnect device shall be provided as part of the building installation. AeroLift must be installed in accordance with the require-

ments of Local Building Codes, Canadian Electrical Code 

(CEC)

, CAN/CSA C22.1 and National Electric Code 

(NEC)

, NFPA 70.

DANGER – To reduce the risk of electric shock:
1. 

Remove power before cleaning.

WARNING – To reduce the risk of burns, fire, electric shock, or injury to 

persons.

2. 

Remove power before putting on or taking off parts.

3. 

Use this mounting system only for its intended use as described in these 

instructions. Do not use attachments not recommended by the manufacturer.

4. 

If AeroLift mounting system is not working properly, call your dealer or Draper, 

Inc., 

(765)

 987-7999.

5. 

Never operate the mounting system with the air openings blocked.

6. 

Never drop or insert any object into any opening.

7. 

Do not use outdoors.

8. 

Installation and calibration of the unit should only be performed by an authorized, 

qualified, and experienced professional. In particular, electrical work and wiring 

[indicated in diagram by dashed lines] must be completed only by a qualified 

professional electrician who has read this manual completely and is familiar with 

the construction and operation of this equipment and the hazards involved.

9. 

Do not affix the unit to walls or ceilings that have inadequate strength to 

permanently hold the unit during use. It is the owner’s and installer’s responsibility 

to confirm the wall or ceiling to which the unit attaches is sufficient to permanently 

hold the weight and stress loads of the unit at all times. Draper

®

, Inc., is not 

responsible for improper installation, application, testing or workmanship related 

to the product at place of installation.

10. 

It is the installer’s responsibility to make sure appropriate fasteners are used for 

mounting. All hardware must be installed level. Unit must be level and square.

12. 

Never leave the area while operating the unit during installation, maintenance, or 

normal operation, unless it is secure and safe.

13. 

Before testing or operation, carefully inspect the entire area and path 

(especially 

underneath)

 of unit to be sure no persons or objects are in the area.

14. 

Turn off power and any nearby equipment or cables carrying electricity before 

connecting switches, wires, controls, or electrical components.

15.` 

Make sure the limit switches are pointed down or accessible when placing the 

motor in brackets.

16. 

All motors should be tested and limits set using test cord before unit is wired.

17. 

Do not wire motors in parallel without written permission from Draper, Inc.

18. 

During testing or operation, carefully watch the surrounding area for any potential 

safety concerns including nearby persons or objects.

19. 

After installation, the entire system, including all sensors, should be carefully 

tested to ensure safe and normal operation. Extreme care should be taken during 

testing to remain clear of moving parts to avoid possible injury.

20. 

Operation of unit should be performed only by authorized and qualified 

personnel, who have been trained in its safe and effective operation and 

understand its safety features.

21. 

The safety features of the unit should never be disabled, bypassed or overridden. 

The system should not be operated until all safety features are properly and 

completely installed, calibrated and tested.

22. 

Unit may need to comply with local, state, or district rules and regulations, in 

particular when installed in schools. All applicable rules and regulations should be 

reviewed before installation and use.

23. 

Failure to precisely follow installation guidelines invalidates all warranties.

24. 

Custom products/installations may not be reflected in this manual. Call Draper, 

Inc., if you have questions about the installation of custom products or any 

questions about your installation..

Before Beginning Installation

1. 

Look for any job site conditions that could interfere with installation or operation 

of the system.

2. 

Read carefully and be sure to understand all installation instructions and all 

related operations manuals. These instructions are intended to serve as a guide 

for the installer and owner. They should be followed closely and combined with 

the expertise of experienced qualified installers. Draper, Inc., is not responsible 

for improper installation, application, testing or workmanship related to the 

product at place of installation. Please retain all instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to make sure you have received the proper unit and parts. 

Controls may be shipped separately, or in same carton as unit .

6. 

If you have any difficulties with installing, servicing, or operating your unit , call 

your dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

Section 1 -

 Hanging Unit

TOP VIEW

TOP VIEW

SIDE VIEW

FRONT VIEW

AeroLift 100 

(Relevant Mounting Dimensions)

SIDE VIEW

FRONT VIEW

AeroLift 150 

(Relevant Mounting Dimensions)

   28

"

(72.4cm)

   28

"

(72.4cm)

  14 

"

(36cm)

  10 

"

(26.7cm)

  26 

"

(67.3cm)

   5

"

(14.6cm)

  14

"

(36cm)

  31 

"

(80cm)

  31 

"

(79.4cm)

  27 

"

(70cm)

 14 

"

(36cm)

 15 

"

(39.1cm)

 11 

"

(29.5cm)

 14 

"

(36cm)

 29 

"

(74.9cm)

  6"

(15.2cm)

 15

"

(38.7cm)

   23

"

(59.4cm)

2

"

(6.2cm)

   

"

(1.9cm)

   

"

(1.9cm)

Mounting Bracket Detail

Top 

Mounting

Hole

Side 

Mounting

Slots

Anti-Slip

Slots

Top 

Mounting

Hole

Side 

Mounting

Slots

Anti-Slip

Slots

The AeroLift 100 / 150 ships with four 

(4)

 mounting angles for suspending the unit from above, or direct mounting from the sides. These angles provide up to 1½" 

(38mm)

  

of adjustment 

(front to back)

. The AeroLift 100 / 150 will fit between joists spaced 16" 

(406mm)

 apart on center 

(assuming 2" joists)

, and will close approximately to 6" 

(152mm)

not including the projector, bracket, or closure. The unit should be guy wired or blocked to prevent swinging. All installations should observe the following guidelines:

1. 

Installer must ensure that all fasteners and supports are of adequate strength to securely support AeroLift 100 / 150 and projector. Hardware structure should hold 

at least four times the combined weight of the lift, projector, housing, closure, and ceiling material attached to closure.

2, 

Fastening methods must be suitable for mounting surface, and securely anchored so that vibration or abusive pulling on unit will not weaken installation.

3. 

Bottom of unit must be unobstructed after 

installation. Sufficient clearance must be allowed 

below projector or optional ceiling closure.

4. 

Do not use unit to support adjacent ceiling,  

light fixtures, etc.

5. 

Do not complete the ceiling below unit until 

electrical connections have been completed  

and unit has been operated successfully.

6. 

Use slots on the projector plate and on the  

closure to adjust the unit to ensure proper 

alignment of ceiling closure relative to  

ceiling opening.

 CAUTION:

 DO NOT hang from, "ride" or pull 

down on the unit. This could create a failure and 

cause damage and/or injury.

page 2 of 8

AeroLift 100/150 220V

Содержание AeroLift 100 220V

Страница 1: ... to height of projector optional projector mounting bracket optional ceiling closure and optional Environmental Housing 3 Arrange to provide service access to the unit 4 When installed with Environmental Air Space Housing unit is suitable for use in an environmental air space in accordance with Section 300 22 C of the National Electrical Code and Section 2 128 12 010 3 and 12 100 of the Canadian E...

Страница 2: ...uthorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 21 The safety features of the unit should never be disabled bypassed or overridden The system should not be operated until all safety features are properly and completely installed calibrated and tested 22 Unit may need to comply with local state or district rules and regu...

Страница 3: ...e 3 Attach assembly to overhead structure Allow clearance between Environmental Air Space Housing top and structure for ease of future access 4 Install side and end panels and trim frame 8 10 6 7 1 5 6 3 1 6 5 8 9 2 4 2 5 6 5 6 11 13 14 12 Item Qty Part Number Description 1 4 C044 193SA Panel B Environmental Air Space Housing Side 2 4 C044 191SA Panel B Environmental Air Space Housing End 3 2 C044...

Страница 4: ... O D x 2mm 8 26 C020 112 Screw 8 32 X 3 8 10mm Type F HWH 9 1 C095 131SA Cover E Environmental Air Space Housing Top 10 1 C028 612 07SA Frame E Trim Ring 11 1 C028 611 01SA Frame E Environmental Air Space Housing Top 12 4 C020 313 Screw 3 8 10mm 16 x 1 25mm GR 5 Zinc Hex Head Cap 13 4 C013 024 Washer 3 8 10mm Flat 14 4 C018 044 NUT 3 8 10mm 16 Zinc Hex Keps 1 Attach Environmental Air Space Housing...

Страница 5: ... Draper universal mounts Section 4 Installing Projector If for any reason the hole placement must be changed completely lower AeroLift before attempting to drill holes When attaching projector bracket to plate make sure screws are short enough that they do not touch the motor roller above the plate when lift is closed Unit and projection system should be operated checked and adjusted as necessary ...

Страница 6: ...uld be made in accordance with wiring diagram AeroLift 100 150 should be operated and checked prior to installing projector and or optional ceiling closure Section 8 Wiring Diagrams IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules A maximum of six 6...

Страница 7: ...clockwise will stop the AeroLift closer to the ceiling Turning it counter clockwise will cause the lift to stop at a lower point Adjusting Up CLOSED position Because the up closed position is preset at the factory Draper does not recommend changing this position using the limit switch The up position of the closure may be changed by changing the length of threaded rod If necessary however up posit...

Страница 8: ...it down then re adjust mounting of 5 16 8mm rods in traveling grid to raise panel required distance 9 Test unit operation to confirm that panel will stop in closed position just before touching ceiling CAUTION DO NOT hang from ride or pull down on unit This could create a failure and cause damage and or injury PLEASE NOTE Immediately upon completing surrounding ceiling operate unit to confirm that...

Отзывы: