Setup and Programming, continued      11

If INPUT B is selected, the B program is used and A filtered
out.  If INPUT A+B is chosen, then both are accepted if
present.

Note: It is OK to use this menu to set up desired program
selections 'off line'. That is, with no actual input at the
present time. Programs may be selected that may not
currently be in the input stream but are desired at some
future time.

Note: It is possible to select both programs with the same
program number - one from A and one from B as long as
the INPUT B offset is set so that the B program number plus
the offset amount does not duplicate a program number
from the A input. The offset is not included in the MPEG
program number display being discussed above but the
offset will be added to all MPEG program numbers from the
B input when they are added to the output multiplex.

PSIP:  

This menu provides a choice of how the unit

organizes the PSIP information from two ATSC streams that
are  being multiplexed.

In the ENABLED setting, information from the MGT and
VCT tables from both signals will be used to build a new
table for the combined output signal. Both input streams
must have these tables present in order for the unit to be
able to perform this operation. EIT tables will be processed
so as to provide program information, if present, for the next
12 hours. This selection is the only one that passes EIT
table program information to the multiplexed output signal.
RRT and STT tables from Demod A are passed through.

If the broadcast station is not transmitting complete MGT
and VCT tables, the ENABLED selection cannot be used. In
this situation, DISABLED may be selected. In DISABLED
mode, the unit does not process or output any MGT, VCT, or
EIT tables. This can be a fine solution for cable systems
that use set top boxes which operate from their own system
channel map and have no need for these tables. MPEG
program information is still processed. Some retail con-
sumer QAM set tops operate perfectly in this mode and
others may not.

The third option is the BASIC MGT, VCT choice. When this
selection is made, the DQT1000 or MQM1000 will build its
own MGT and VCT tables from the incoming streams even
if one or both of the streams do not contain these tables.
This solution should satisfy all types of set top boxes but
will not provide any EIT table program guide information.

The STT and RRT tables from the source are passed
through unchanged in the ENABLED mode and filtered out
in the other modes.

VCT TABLE:

 This menu is only available when ENABLED

or BASIC MGT, VCT has been selected in the previous
PSIP menu. You may select the TVCT - TV channel table or
CVCT table for CATV. Usually the TVCT choice must be
selected for ATSC input signals.

MAJOR CHANNEL:

 This menu is not available if PSIP is

disabled. This setting will determine how a channel number
is displayed on a consumer TV if the TV is tuning the output
of the MEQ1000 without a cable box.

When ORIGINAL is selected, the major channel number
indicated in the output tables will be that sent by the original
broadcaster. If OUTPUT CHANNEL is selected, the major
channel number will be set to the channel number of the
MEQ1000 RF output channel.  When a cable box is used, it
usually does not require or use this information.
Minor channel numbers are the same as those input via
module A and as input via module B with the offset added to
the B side programs.

When USER DEFINED is selected and the remote control
software is used to allow programming via a PC, then the
MPEG program number and the major and minor virtual
channel numbers may be set to whatever number the
operator chooses providing total flexibility. These numbers
cannot be programmed with the front panel buttons but only
via a PC and the RS232 interface of the MEQ1000.
It is up to the operator to insure that no duplications are
made when using this mode.

QAM MODE:

 This menu allows the user to set the modula-

tion type for the output. Choices range from 16-QAM
through 256-QAM.   'A' suffixes indicate DVB compliant FEC
and the 'B' suffixes indicate DigiCipher II FEC encoding.
Note that when using the MEQ1000 in the multiplex mode,
the output QAM mode usually must be 256-QAM. For CATV
systems using DigiCipher II, select the QAM-256B mode.
For DISH Network QAM distribution or other DVB systems
using DVB set tops, choose the QAM-256A mode.

When used for a single input processing function, choose
the output mode accordingly from any of the available
options that will provide a high enough data rate.

GRAY ENCODING: 

This menu is only available when QAM

modes QAM-16A through QAM-1024A, are selected.  The
choices are DVB and DAVIC. Gray Encoding is normally not
used for video data.

QAM SYMRATE:  Preset or Manual:

  If PRESET is

selected, the symbol rate will be automatically set to the
‘normal’ rate based on the QAM mode that is selected and
assuming a 6 MHz wide QAM channel.   If MANUAL is
selected, pressing the right  or left arrow buttons will allow
selection of symrates from 1.000 thru 7.000 MSym/Sec
using the up and down arrow buttons.

QAM SYMRATE:

 This menu allows selection of the output

QAM baudrate or symbol rate. Set as required by the set
top box. When multiplexing two ATSC input signals, in
DigiCipher II, 256-QAM CATV systems, this is usually
5.3606 Ms/s. In DVB systems, the rate would be 5.264
Ms/s. In any case, the rate must be high enough to provide
a data bitrate of at least 38.81 Mbps (do not confuse this
with the symbol rate). If the set top box requires a fixed
higher rate, this may be manually set.

Содержание SDE24

Страница 1: ... of R L Drake LLC Copyright 2010 R L Drake LLC P N 3852511_D 03 2010 Printed in U S A MEQ1000 Hybrid QAM Modulator DTD1000 Digital Tuner and Demodulator Module SDE24 Encoder module ASII ASI Input Module ENTER 0 000 Mbits S QAM OUTPUT MEQ1000 Multiplexing Edge QAM Modulator SELECT ...

Страница 2: ...rturn The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating an...

Страница 3: ...wer outlet only one way This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the plug If the plug should still fail to fit contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the polarized plug Alternate Warnings If this product is equipped with a three wire grounding type plug a plug having a third grounding pin...

Страница 4: ...acement Parts When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part Unauthorized substitutes may result in fire electric shock or other hazards 21a Pièces de rechange Si des pièces de rechange sont nécessaires s assurer que le technicien de service a employé des pièces de rec...

Страница 5: ...ble and user adjustable audio gain 15dB MPEG2 or MPEG4 H 264 selectable MPEG2 only Encoding Bitrate Video Adjustments Audio Encoder Selectable types AC3 Encoder Output bitrate Output Constant Bitrate 1 Mbps to 8 Mbps Brightness Contrast Saturation Hue AC3 Dolby digital Stereo OR MP2 MPEG1 Layer 2 Manufactured under license from Dolby Laboratories 320 kbps The output of each SDE24 module is connect...

Страница 6: ...d rate and remodulated on the same or another RF channel Applications include cleaning up a low MER QAM signal received from a CATV source or fiber link receiver or shifting the RF frequency of a QAM modulated signal It may be used to convert one off air ATSC 8VSB signal to a QAM output with rate adjustment Used in the processor mode with only one input the DQT1000 can process ATSC or CATV QAM inp...

Страница 7: ...e adjust mode Using only these buttons will not change any parameter settings After a short period of button inactivity the default display will be returned F5 F6 Up and Down Buttons Use the down and up arrow buttons to change the value of a viewed parameter setting The unit must be in the adjust mode with the display flashing in order for these buttons to become active for changing a parameter se...

Страница 8: ...7 R8 countries with 120 VAC power standards but the power supply will accept an input voltage range of 90 VAC minimum to 260 VAC maximum with a power line fre quency of either 50 or 60 Hz R9 ASI Input type BNC connector Applies to ASII module if present This input is for a 270 MHz clocked SPTS or MPTS serial input The maximum data rate is 80 Mbps for a given ASII module R10 ASI Loop type BNC conne...

Страница 9: ...L DTD1000 CHANMAP DTD1000 Demodulator BROADCAST CATV IRC HRC 1 158 VSB 8 QAM 64B QAM 256B ADJUST MODE ASII MODULE MAJOR TABLE VCT PROGRAMS MPEG INPUT B BAUDRATE RS232 UNIT ID Select 0 63 19200 9600 4800 2400 OFFSET SELECT ALL PROGS SELECT PROGRAMS PSIP OUTPUT CHANNEL CHANNEL ADJUST MODE MULTIPLEX USE A INPUT ONLY USE B INPUT ONLY ENABLED 0 90 ENABLED BASIC MGT VCT DISABLED CVCT TVCT USER DEFINED O...

Страница 10: ... in the A or B inputs will be filtered out If INPUT A is selected the A input program only is used This section provides additional details regarding the selectable items shown in the adjust mode on the Software Flow Chart on page 8 SETUP MEQ1000 UNIT ID Select the desired unit identification number when connecting the RS232 IN connector to a PC or modem for remote control using Drake Remote Contr...

Страница 11: ...Usually the TVCT choice must be selected for ATSC input signals MAJOR CHANNEL This menu is not available if PSIP is disabled This setting will determine how a channel number is displayed on a consumer TV if the TV is tuning the output of the MEQ1000 without a cable box When ORIGINAL is selected the major channel number indicated in the output tables will be that sent by the original broadcaster If...

Страница 12: ...ng section for detail 9 In the VCT TABLE menu select TVCT 10 In the MAJOR CHANNEL menu select OUTPUT CHAN NEL This may be changed later 11 From the QAM MODE menu set the QAM modulator to QAM 256B for use in a DigiCipher II environment If DVB use QAM 256A instead 12 In the QAM SYMRATE menu select PRESET 13 Set the INTERLEAVER to I128 J1 if in a DigiCipher II environment There is no interleaver menu...

Страница 13: ...d select the number of the encoder you choose to program In this case Input A contains an SDE24 which contains two encoders Select radio button 1 and program each parameter to the desired value Select radio button 2 and set each FIGURE 4 FIGURE 5 7 This screen allows the user to reasign MPEG numbers as well as new major and minor channel numbers 8 Once the selec tions have been made click on the D...

Страница 14: ...row will cause the percentage of buffer capacity that is currently in use on the left side of the display and the maximum percentage of buffer capacity that has occurred since the unit was last programmed on the right side for the QAM output selected REMOTE CONTROL AND MONITORING The MEQ1000 may be used with the Drake Digital Headend Remote Control Software program to allow remote monitoring or co...

Страница 15: ...11 117 123 129 135 141 147 153 159 165 171 177 183 189 195 201 207 213 219 225 231 237 243 249 255 261 267 273 279 285 291 297 303 309 315 321 Channel Number CABLE TV CHANNELS Center of Channel Channel Number CABLE TV CHANNELS Center of Channel EIA NCTA Numeric Equivalent 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 8...

Страница 16: ...1 527 533 539 545 551 557 563 569 575 581 587 593 599 605 611 617 623 629 635 641 647 653 659 665 671 677 683 689 695 701 707 713 719 725 731 737 743 749 755 761 767 773 779 785 791 797 803 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 Center of Channel Frequency MHz UHF BROADC...

Страница 17: ...orking days after it arrives at R L DRAKE if we have all the facts If we must call you it may take longer R L DRAKE is not responsible for damage caused by lightning nonprofes sional alterations acts of God shipping damage poor storage handling etc R L DRAKE will make note of any shipping damage upon receipt You will need to send proof of purchase to receive warranty service Typically a copy of th...

Страница 18: ...e are important to obtain proper performance from this product Therefore carefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE LLC determines is due to 1 Improper maintenance or repair including the installation of parts or accessories that do not conform to the quality and specifications of the original parts 2 Misuse abuse neglect or improper installatio...

Страница 19: ...R L Drake LLC 230 Industrial Drive Franklin Ohio 45005 U S A Customer Service and Parts Telephone 1 937 746 6990 Telefax 1 937 806 1576 World Wide Web Site http www rldrake com ...

Отзывы: