![Dräger X-plore 3300 Скачать руководство пользователя страница 159](http://html.mh-extra.com/html/drager/x-plore-3300/x-plore-3300_instructions-for-use-manual_2526849159.webp)
Use
X-plore 3000
159
3.3
Leak tests
3.3.1
Negative pressure test
Seal both respiratory filters with your hands or an aid (e.g. a piece
of cardboard) and breathe in until a negative pressure is created
(refer to figure H). Hold your breath for a moment.
The negative pressure should be maintained. If not, adjust the
harness.
3.3.2
Positive pressure test
Seal the exhalation valve of the half mask and breathe out
forcefully (refer to figure J).
The half mask must NOT lift off your face. If the exhaled air
dissipates between face and mask body, adjust the harness.
WARNING
The half mask may not fit correctly over facial hair or features
– danger of poisoning!
The half mask must fit tightly and the respiratory filters must be
fitted before entering the contaminated area.
NOTICE
The pad cap of pad-particle filters does not provide an airtight
seal for the gas filter and/or the pad plate. Thus, it is necessary
to carry out the positive pressure test for pad-particle filters.
!
i
i
Содержание X-plore 3300
Страница 2: ...2 X plore 3000 1 2 3 4 A B D C 2 3 1 1 1 2 00121923 eps X plore 3300 X plore 3500 1 2 3 4 2 3 ...
Страница 3: ...X plore 3000 3 E F G H J K 00221923 eps ...
Страница 165: ......
Страница 168: ...0158 Australian Standard AS NZS 1716 2012 Lic No 1346 SAI Global TP TC 019 2011 ...
Страница 170: ......
Страница 171: ......