![Dräger X-plore 3300 Скачать руководство пользователя страница 157](http://html.mh-extra.com/html/drager/x-plore-3300/x-plore-3300_instructions-for-use-manual_2526849157.webp)
Use
X-plore 3000
157
at least 17 % volume oxygen in all European countries except
the Netherlands, Begium and the UK
at least 19 % volume oxygen in the Netherlands, Begium and
the UK, Australia and New Zealand
at least 19.5 % volume oxygen in the US
For other countries observe national guidelines.
3.1.1
Special NIOSH requirements
In order to make sure that the correct facepiece size is used, per-
form a fit test. The fit test is to be conducted in accordance with the
requirements outlined in the OSHA Respiratory Protection Stan-
dard 29 CFR, Part 1910.134.
3.2
Preparation for use
3.2.1
Assembling the half mask
1. Arrange the harness.
2. Fit the yoke on the mask body.
3. Fit two new respiratory filters.
3.2.2
Fitting the respiratory filters
1. Hold bayonet-type connector with your hand (refer to figure B).
2. Position two respiratory filters (refer to figure C1: The line
markings must line up!) and insert them until they lock into place
(refer to figure C2) by twisting each respiratory filter downwards
until a stop is felt.
Ensure that the line marking of the respiratory filter is above the
end of the arrow.
CAUTION
When fitting the respiratory filters, make sure that the mask
body is not being kinked.
Otherwise, the mask body could be damaged.
!
Содержание X-plore 3300
Страница 2: ...2 X plore 3000 1 2 3 4 A B D C 2 3 1 1 1 2 00121923 eps X plore 3300 X plore 3500 1 2 3 4 2 3 ...
Страница 3: ...X plore 3000 3 E F G H J K 00221923 eps ...
Страница 165: ......
Страница 168: ...0158 Australian Standard AS NZS 1716 2012 Lic No 1346 SAI Global TP TC 019 2011 ...
Страница 170: ......
Страница 171: ......