Issue date: 17 November 2006
32 of 80
LFB image 1136780
LFB image 684780
14.73
After connections are complete – test the press-stud is
secure by placing two fingers under the flap of the ‘Dräger’
motif and pull gently.
14.74
Repeat this process for the other anti-entanglement strap.
14.75
The cylinder cover with anti-entanglement fixture is now
complete.
14.76
Removal of the cylinder cover is a reversal of the above.
Cylinder cover cleaning
14.77
Cleaning the cylinder cover:
•
Use warm soapy water and a cloth.
•
Wipe off with clean warm water.
•
Stubborn stains can be removed with the aid of a nylon hand brush and undiluted soap.
•
Abrasive cleaners are
not to be used
.
•
If in doubt contact OSG for further advice.
15
SDBA set – lifting and carrying instructions
15.1
If moving the SDBA set from one area to another don the set as per don and start so that the set
harness and waist belt are secured, this will ensure that the weight is transferred through the hips
and legs. The face mask can be left in the bag and carried in one hand.
16
EDBA cylinder
General
16.1
Cylinder volume is 6.8 litres (water capacity) x two and is charged to a working pressure of 300
bar.
16.2
Contains 3672 litres of compressed breathable air when charged to 300 bar.
16.3
Hydraulically tested every five years.
16.4
Design life is 15 years.
16.5
The cylinder must be used with a cylinder cover.