476 

Issue date: 17 November 2006 

49 of 80 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set reduced volume: 

20.50

 

When all the segments have switched off, the display will change to ‘reduced 
volume’ icon. When the ‘reduced volume’ icon appears the wearer should first 
press the 

left

 button followed by the 

right

 button to confirm this setting (see 

image right). 

20.51

 

When all the segments have switched off, the display will change momentarily to 
‘automatic (motion sensor) DSU not active’ icon (see image right). 

 

 

 

20.52

 

The display will then quickly change to ‘non-operational mode’ (see image right). 

 

 

Note: the display of an ‘X’ or ‘telemetry fault code’ icon alerts the 
user that the Bodyguard 7000 has failed the ‘self-check’ or the 
telemetry module has failed. Return the BA set to OSG (see    
images right). 

’Do not use after date’ and ’B’ test: confirm BA set I.D. 

20.53

 

To confirm the do not use after date and the BA set 
number; after the completion of the ‘self-check’ as in 
paragraph 13.1 above press the

 right 

button and the 

do not use after date, followed by the four digit BA 
set number will scroll across the display screen from 
right to left (the example above is BA set 0029). 
Check this date to ensure it corresponds with the 
front of the BA log book as per 20.2 above. 

’B’ test: test automatic and manual distress signals 

20.54

 

Operate

 the first breath button. 

20.55

 

Put neck loop on and 

connect

 the face mask to the retaining stud 

and check it holds securely. 

20.56

 

Remove Bodyguard key,

 

note the reduced volume of the 

Bodyguard. Note ‘green’ flashing LED and zero display (see     
image right).  

20.57

 

Open

 the cylinder valve slowly and fully. The cylinder must have a minimum pressure of 

270

 bar 

to start the test. If cylinder change is required enter the cylinder bar code number into BA log 
book. Note

 

the pressure reading for entry into the BA log book. 

20.58

 

Test

 ADSU, to check pre alarm signal, confirm the ‘green’ LED continuously flashes. 

20.59

 

Wait 30 seconds – pre-alarm sounds – cancel pre-alarm (tap side of unit).   

Содержание LFB PSS 7000

Страница 1: ...rk team RPE and Hazmat PPE Contents 1 Introduction 3 2 Component parts 6 3 Backplate assembly 9 4 Harness and cylinder strap assembly 10 5 Telemetry module 11 6 Charging BA set from appliance 11 7 FPS...

Страница 2: ...53 22 Defective equipment 54 23 RPE maintenance rooms 56 24 Technical data 57 Glossary RPE generic 60 Appendix 1 Working in hi expansion foam 61 Appendix 2 Returning the BA set to OSG 62 Appendix 3 A...

Страница 3: ...ng a consumption rate of 58 litres per minute LPM The safety margin duration is 18 minutes with the electronic low pressure warning LPW actuating at 84 bar 1 4 For operational use the complete BA set...

Страница 4: ...terface unit display DSU button and low pressure warning device Padded shoulder harness SDBA 8 litre cylinder and cover BA personal line escape hood and BA cable cutter Second person connection and Bo...

Страница 5: ...play DSU button and low pressure warning device Padded shoulder harness EDBA 6 8 x 2 cylinder pack and cylinder cover BA personal line escape hood and BA cable cutter Second person connection and Body...

Страница 6: ...line connection QRC 7 FPS 7000 dual purpose face mask 8 Lung demand valve LDV 9 Waist belt adjustment buckles 10 Waist belt buckle 11 BA personal line housing karabiner attached to small D ring 12 Bac...

Страница 7: ...ure sensor housing 22 Padding material high wear resistance and high grip properties 23 Shoulder strap adjustment buckles 24 Hose sleeves on shoulder harness to reduce snagging and are reflective a Le...

Страница 8: ...cate differences from SDBA 26 Lower cylinder connection guide 27 EDBA entry control tally red 28 Upper cylinder retaining bracket incorporating spring clip 29 Red sleeve to in line connection hose 30...

Страница 9: ...e assembly slides and pivots in response to the twisting and bending movements of the upper body of the wearer This flexibility improves the weight distribution and provides freedom of movement and in...

Страница 10: ...s in the guide arms when an audible click will be heard locking and securing the shoulder yoke to the required height setting 3 18 This adjustment is carried out during A and B testing if required 4 H...

Страница 11: ...ery pack located in the backplate of the breathing apparatus An in cab charger provides charging via a charging port incorporated into the telemetry module 5 4 Supplied with each module is a matching...

Страница 12: ...d to ensure it is securely held The connector will automatically disconnect when the BA set is removed from the BA set stowage bracket 6 4 Once connected the Bodyguard will carry out a short test sequ...

Страница 13: ...contact OSG Single flash amber Charging fast low capacity Leave on charge Double flash amber Fault Battery low capacity or battery temp may be too high or too low Remove from charge Leave approximatel...

Страница 14: ...sk see section 18 for details 7 5 The FPS 7000 DPFM can be fitted with a P3 particulate filter to protect personnel from the effects of exposure to airborne particulates 7 6 The FPS 7000 face mask can...

Страница 15: ...lve LDV Operation of the LDV 8 1 Before opening the cylinder valve the first breath mechanism must be operated To do this press the green first breath button on the top of the LDV which will lift and...

Страница 16: ...designed to maintain positive pressure inside the mask Use in hi expansion foam 8 12 For use in hi expansion foam the outer rubber casing should be released from the body of the LDV prior to use see a...

Страница 17: ...plies the EMU for monitoring the air pressure in the compressed air cylinder 9 13 The hose construction although appearing similar to medium pressure hoses differs in its internal construction Inside...

Страница 18: ...r padding outside the hose sleeve and to the left of the Bodyguard supply hose The second hose clip is positioned on the top of the left shoulder padding The clip should be attached to the underside o...

Страница 19: ...d user interface unit Description and use 11 2 The Bodyguard user interface unit display features a digital screen for viewing the cylinder pressure in numeric and radial segments scrolling of user de...

Страница 20: ...All electronic devices may suffer a temporary loss of function if subjected to high levels of radio frequency RF radiation The Bodyguard will continue to operate with no loss of performance or loss of...

Страница 21: ...signal an audible alarm for help and assistance manually 12 13 Press the yellow button in the centre of display unit to start the DSU alarm see image right 12 14 A repeating audible alarm is emitted a...

Страница 22: ...f BA set fails to charge remove the set from service and return to OSG see image right 13 2 Press and hold the left button of the Bodyguard unit and continue holding until the return arrow icon appear...

Страница 23: ...to left the example above is BA set 0029 14 SDBA cylinder General 14 1 Cylinder volume is eight litres water capacity and is charged to a working pressure of 300 bar 14 2 Contains 2160 litres of compr...

Страница 24: ...when empty approximately 5 55 kg Weight when full approximately 8 50 kg Right angle cylinder valve 14 13 The outlet connection of the valve for connection to SDBA is to DIN ISO 228 1 G5 8 LFB image 19...

Страница 25: ...e air from being discharged from the cylinder 14 20 Turning the hand wheel of the valve anti clockwise looking at the top of the hand wheel rotates both the spindle and the threaded lower spindle open...

Страница 26: ...5 2002 standard to which cylinder is manufactured to GB 2009 04 year and month of manufacture FINAL 2039 04 end of design life year month TS 50o C 60o C operating temperature range PS max 374BAR at 60...

Страница 27: ...t Do not use cylinder once month and year shown has been reached b The body of the cylinder is scored so as to reveal the carbon fibre matrix c After removing the protective blank cap the cylinder con...

Страница 28: ...tywash solution and mark cylinder empty M T on the black quarter shoulder Cylinder and cover replacement SDBA 14 53 The cylinder cover is provided with a full length zip incorporating a small Velcro p...

Страница 29: ...pass over it 14 59 Line up the two connections see image 684786 right Note the reducer cylinder connection pivots forwards and backwards and therefore may not line up vertically with the cylinder con...

Страница 30: ...uring it functions correctly see image 684785 right Attaching the anti entanglement straps 14 65 Extend the BA set shoulder straps fully to ease attachment of the anti entanglement straps to the BA se...

Страница 31: ...press stud and use your thumb on top to create a depression or use work surface 14 71 Offer up the female part of the press stud to the male part on the shoulder strap of the BA set ensuring that the...

Страница 32: ...aid of a nylon hand brush and undiluted soap Abrasive cleaners are not to be used If in doubt contact OSG for further advice 15 SDBA set lifting and carrying instructions 15 1 If moving the SDBA set...

Страница 33: ...BA set see arrowed in image 178632 right 16 10 The cylinder pack is attached to the BA set by a quick release spring plate fitted to the central cylinder retaining bracket on the backplate of the BA...

Страница 34: ...cylinder bar code number should be recorded in the BA log book after every change of cylinder It is not required to be recorded in the log book for every A test Cylinder removal EDBA 16 21 The BA set...

Страница 35: ...t Cylinder pack replacement EDBA 16 30 With the cylinder valve nearest you and facing upwards lift and position the backplate of the BA set over the twin cylinder pack with the reducer towards the cyl...

Страница 36: ...procedure as per SDBA see section 14 65 to 14 74 16 37 The cylinder cover with anti entanglement fixture is now complete 16 38 Removal of the cylinder cover is a reversal of the above Cylinder cover c...

Страница 37: ...d conditions Following this wear the BA set will be the subject of a B test 18 7 The 28 day test can be carried out by personnel issued with a personal issue face mask Provided that any BA set is not...

Страница 38: ...sure when a Bodyguard download takes place and that unnecessary time is not lost identifying the reason an A test hasn t taken place the phrase APPLIANCE OTR needs to be entered in the comments sectio...

Страница 39: ...ecurely Then a Inspect the condition of shoulder straps waist belt ensuring they are fully extended fastening buckle fittings BA personal line housing ensure karabiner is attached to the small D ring...

Страница 40: ...d volume icon appears the wearer should first press the left button followed by the right button to confirm this setting see image right 19 11 When all the segments have switched off the display will...

Страница 41: ...wo blue two red and one green illuminate alternatively Insert Bodyguard key to cancel 19 21 Test DSU by pressing the yellow button in the centre of the unit to start the manual DSU alarm Check LEDs tw...

Страница 42: ...d the BA set did not pass the test see image right Purge remaining air by operating the additional flow button Check the cylinder connection is tight and the LDV is connected to the face mask correctl...

Страница 43: ...fall in pressure shown on the Bodyguard display 19 41 After 8 seconds slowly breathe down the contents Observe and listen 19 42 Observe and listen to a The electronic low pressure warning and the red...

Страница 44: ...to get a seal with a range of standard issue face masks is to be taken off the run and placed on light duties OSG is to be informed as soon as possible and will arrange for a face fit test to be cond...

Страница 45: ...ask can be damaged by using higher dosages of cleaning solution and or applying them for a longer period of time than stated above 20 6 After washing the face mask should be shaken to remove excess wa...

Страница 46: ...nscrew the cylinder connection to the reducer 20 17 Remove the cylinder from the retaining strap in the opposite direction to the cylinder connection 20 18 Remove the cylinder cover and inspect for we...

Страница 47: ...tion of the additional flow button at the front of the LDV a click should be heard this confirms that the mechanism has operated Repeat this test B test general cleaning and inspection of the BA set 2...

Страница 48: ...ection 14 for SDBA and section 16 for EDBA c Fit the cylinder for detail see section 14 for SDBA and section 16 for EDBA d The cylinder should now be held secure with no movement Ensure cylinder cover...

Страница 49: ...mpletion of the self check as in paragraph 13 1 above press the right button and the do not use after date followed by the four digit BA set number will scroll across the display screen from right to...

Страница 50: ...If no action is taken by the time the last segment disappears the low pressure icon is momentarily displayed followed by the self check icon which will restart 20 65 When the leak test icon appears p...

Страница 51: ...e head harness over the head locating the harness centre plate square on the back of the head Ensure that hair does not compromise the face seal area 20 75 Tighten both lower straps together and then...

Страница 52: ...release sliding buckles and remove the face mask 20 88 Extend straps wipe the face mask seal and inner mask with a damp PALTECH wipe 20 89 Check and ensure the two inner mask non return valves are in...

Страница 53: ...l radio icon on ECB see image right telemetry signal radio icon ticked for in telemetry signal 20 97 Replace Bodyguard key check that the Bodyguard returns to the battery charging icon see 20 96 above...

Страница 54: ...d from OSG Operations Support Centre OSC on receipt of a POMS order Once the item has been received the station should close the order on POMS 22 4 Stations should contact logistics manager at RMC on...

Страница 55: ...rap EDBA 22 14 Damaged cylinder cover not requiring immediate replacement Damaged reflective strip Tears or splits in the fabric except as in 22 13 above Stitching becoming unravelled Note if in doubt...

Страница 56: ...n RPE nor should they be used for the cleaning of other items 23 2 Serious accidents can result from the misuse of RPE and oxygen equipment The materials provided for the cleaning and maintenance of R...

Страница 57: ...he equipment is CE mark approved and is issued with an EC type examination certificate 24 7 ATEX certification 94 9 EC for specific combinations of the PSS7000 Series the approved groups classes is de...

Страница 58: ...ment requirements stipulated in EN 137 24 31 Face mask weight approximately 600 g Connection 24 32 ESA einheit stecken anschluss German translated into standard plug in connection 24 33 Connection can...

Страница 59: ...V m to ISO11452 Part 2 compliance Power supply 24 45 Main power 6 5 volts 24 46 Low battery warning 5 5 volts 24 47 Power up shut off 5 0 volts 24 48 The Bodyguard electronic monitoring unit is powere...

Страница 60: ...th and Safety Executive IC Incident commander IS Intrinsically safe LCD Liquid crystal display LED Light emitting diode LPW Low pressure warning can be electronic or pneumatic in operation LPM Litres...

Страница 61: ...rubber casing so as to equalise the pressure on the constant flow button Removing the outer rubber protective casing 3 Insert finger under outer rubber casing on the opposite side to medium pressure...

Страница 62: ...ess and LDV supply hose should lay inside the face mask The LDV hose should be detached from the BA set at the in line connection see image 250388 3 Secure the face mask bag using the Velcro seal see...

Страница 63: ...Bring both halves of the waist belts across the front of the shoulder straps trapping them underneath as shown see image 1136802 10 Turn the set over and connect the waist belt buckles turn set over a...

Страница 64: ...rear BA tally and telemetry module Log book front and rear Bodyguard number checked at EV 15 Note if mismatch found check all other BA sets on station before contacting OSG 4 CHECK the condition of cy...

Страница 65: ...uick release couplings Protective blank cap Hoses 10 CHECK the LDV connection gently push twist and pull 11 CHECK the face mask and fittings Head harness straps are not twisted and are correctly roved...

Страница 66: ...olds securely 18 REMOVE the Bodyguard key noting the reduced volume of Bodyguard repeat from EV 13 if not reduced 19 OPEN the cylinder valve SLOWLY and FULLY The cylinder must have a minimum pressure...

Страница 67: ...est timing icon appears for approximately one minute Bar segments progressively switch off clockwise Note during the leak test a pressure drop of up to 10 bar is acceptable 27 On completion the leak t...

Страница 68: ...conds and then BREATHE normally 33 TAKE a deep breath and hold CLOSE the cylinder valve continue to hold onto the valve 34 TAKE HOLD of the Bodyguard in other hand and OBSERVE display for approximatel...

Страница 69: ...the face mask into its bag Note do not attach neck loop retaining stud 43 FILL OUT the BA tally enter rounded down pressure noted at EV 37 ENSURE that printed details on the BA tally are clear and ent...

Страница 70: ...the two non return valves are in place and are seated correctly 3 CHECK the nine identification numbers match and are legible located on the Face mask LDV Backplate front and rear BA tally and telemet...

Страница 71: ...p of the LDV RELEASE the first breath mechanism by operation of the additional flow button on the front of the LDV a click should be heard this confirms the mechanism has operated REPEAT this test 10...

Страница 72: ...t cylinder and CHECK for damage to the surface of the cylinder CHECK the cylinder connection thread is free from dirt and not damaged NOTE the cylinder bar code number for entry into the BA log book E...

Страница 73: ...it holds securely 25 REMOVE the Bodyguard key noting the reduced volume of repeat from EV 20 if not reduced 26 OPEN the cylinder valve SLOWLY and FULLY The cylinder must have a minimum of 270 bar to s...

Страница 74: ...n appears for approximately one minute Bar segments progressively switch off clockwise Note during the leak test a pressure drop of up to 10 bar is acceptable 34 On completion the leak test passed ico...

Страница 75: ...m the face mask for approximately 8 seconds and then BREATHE normally 40 TAKE a deep breath and hold CLOSE the cylinder valve continue to hold onto the valve 41 TAKE HOLD of the Bodyguard in other han...

Страница 76: ...ally are clear and enter rank and name 51 CHECK operation of BA set retaining bracket and adjust height if appropriate CONNECT charging lead REPLACE BA set and ensure that the BA set is being charged...

Страница 77: ...its to operation this can be downgraded according to number of charging points available 1 PL P 1 d 4 FRU Aerial appliances Any BA set charging point defect Note BA sets can be rotated with charged BA...

Страница 78: ...t updated 14 01 2011 Throughout Incorporation of PN 479 EDBA and telemetry Removal of Don and start now contained in PN 466 RPE Operational Procedures 31 05 2011 Appendix 8 Appendix added contains BA...

Страница 79: ...to paragraph 10 01 2018 Page 44 para 19 Throughout Wearing Nitrile gloves for B test added Style change and addition of version 7 A and B test Wypall X80 clothes are no longer to be used for face mas...

Страница 80: ...g subjects BA BA entry control board BA tallies Breathing apparatus Drager PSS7000 EDBA Respirator RPE SDBA Standard Tests Freedom of Information Act exemptions This policy procedure has been securely...

Отзывы: