background image

6

Instructions for use

  |  

Dräger BG ProAir

  

Safety-related information 

1 Safety-related 

information

– Before using this product, carefully read these instructions 

for use and those of the associated products.

– Strictly follow the instructions for use. The user must fully 

understand and strictly observe the instructions. Use the 

product only for the purposes specified in the intended use 

section of this document.

– Failure to use the product as described in these 

instructions for use can lead to reduced protection.

– Do not dispose of the instructions for use. Ensure that they 

are stored and used appropriately by the product user.

– Only trained and competent users are permitted to use 

this product.

– Comply with all local and national rules and regulations 

associated with this product.

– Only trained and qualified personnel are permitted to 

inspect, repair and service the product as detailed in these 

instructions for use (see "Maintenance", page 14). Further 

maintenance work that is not detailed in these instructions 

for use must only be carried out by Dräger or personnel 

qualified by Dräger. Dräger recommend a Dräger service 

contract for all maintenance activities. 

– Use only genuine Dräger spare parts and accessories. 

Otherwise, the proper functioning of the product may be 

impaired.

– Notify Dräger in the event of any component fault or 

failure.

– Do not use a faulty or incomplete product. Do not modify 

the product.

Conventions in this document

2.1 Meaning 

of 

the warning notices

The following warning notices are used in this document to 

alert the user to potential hazards. The meanings of the 

warning notices are defined as follows:

2.2 Trademarks

The following website lists the countries in which the 

trademarks from Dräger are registered: 

www.draeger.com/trademarks.

The trademarks listed are only registered in certain countries 

and not necessarily in the country in which this document is 

published.

3 Description

3.1 Product 

overview

See overview graphic at the start of the instructions:

Warning 

sign

Signal word

Classification of the warning 

notice

WARNING

Indicates a potentially hazard-

ous situation. If not avoided, it 

could result in death or serious 

injury.

CAUTION

Indicates a potentially hazard-

ous situation. If not avoided, it 

could result in physical injury. It 

may also be used to alert 

against unsafe practices.

NOTICE

Indicates a potentially hazard-

ous situation. If not avoided, it 

could result in damage to the 

product or environment.

Trademark

Trademark owner

Bluetooth

®

Bluetooth SIG, Inc.

1

Exhalation hose

2

Connecting piece with protective cap

3

Bayonet ring

4

Inhalation hose

5

Bypass hose (red)

6

Medium-pressure hose to sensor unit (blue)

7

Medium-pressure hose for the oxygen supply (blue)

8

Carrying frame

9

Buddy-light

10

Onboard electronics (sensor unit)

11

Breathing air cooler

12

Minimum valve

13

Relief valve (under the spring bridge)

14

Breathing bag

15

Pressure reducer incl. hand wheel

16

Hand wheel of cylinder valve

17

Pressure indicator on cylinder valve

18

Bypass button

19

Cylinder strap

20

Drainage valve (between carrying frame and com-

pressed oxygen cylinder)

21

Compressed oxygen cylinder

22

Spring bridge

23

Locking lever

24

CO

2

 absorber

25

Lid

26

Window for buddy-light

27

Connect ECU ("Electronic Control Unit")

27-1

Graphical pressure display

27-2

Cylinder pressure

Содержание BG ProAir

Страница 1: ...Instructions for use Dr ger BG ProAir More languages available for download at draeger com ifu Dr ger BG ProAir...

Страница 2: ......

Страница 3: ...200 0 02 bar h elapsed time 1 4 2 3 27 27 11 16 9 10 8 29 28 24 25 26 14 15 12 13 19 20 23 22 21 5 6 7 17 18 31 30 8 7 6 9 1 2 3 4 5...

Страница 4: ...digitalt exemplar p andra spr k i databasen f r teknisk doku mentation www draeger com ifu SV 9300712 ET Selle kasutusjuhendi saab teistes keeltes elektroonili sel kujul alla laadida tehnilise dokume...

Страница 5: ...use 12 4 3 1 Freezing the ice packs for apparatuses with ice cooler 12 4 3 2 Inserting ice packs for apparatuses with ice cooler 12 4 3 3 Donning the closed circuit breathing apparatus 12 4 3 4 Activ...

Страница 6: ...to potential hazards The meanings of the warning notices are defined as follows 2 2 Trademarks The following website lists the countries in which the trademarks from Dr ger are registered www draeger...

Страница 7: ...g cooler options are available Ice cooler The ice cooler contains ice packs that can be refrozen after use Regeneration cooler The regeneration cooler PCM phase chage material cooler contains a latent...

Страница 8: ...following information is shown when the compressed oxygen cylinder is opened Other information and queries are shown if the Connect ECU is turned on differently pushbutton insertion of batteries remo...

Страница 9: ...mmersion of the apparatus in water e g when navigating a waterhole in a mine will not impair the function of the closed circuit breathing apparatus If the closed circuit breathing apparatus has been c...

Страница 10: ...ion on approvals see supplement 9300233 3 6 Type identifying markings and explanation of symbols 3 6 1 Type identifying marking The type identifying marking of the BG ProAir Class 4P is located on the...

Страница 11: ...ored for 6 months The apparatus must have successfully passed the leak test and be sealed with the protective cap The air tight shrink wrapped or installed CO2 absorber was not transported on a vehicl...

Страница 12: ...ing aid to prevent the ice packs from deforming Make sure that no ice is deposited on the ice packs If necessary place ice packs in a bag seal the bag and freeze the ice packs whilst they remain in th...

Страница 13: ...g the automatic distress signal function Remove the function key from the Connect ECU This activates the motion sensor The symbol is displayed 4 4 During use 4 4 1 General information The chemical pro...

Страница 14: ...ecess when tightening the bayonet ring Rotate the bayonet ring clockwise onto the connection to fasten the breathing hose The breathing hose is correctly fitted when a clicking sound is heard while ti...

Страница 15: ...k the catches on the fasteners under the tabs see Figure B 1 Push the fasteners closed see Figure B 2 Connecting piece The direction of flow is marked with an arrow on the connecting piece The directi...

Страница 16: ...g circuit may contain base which may leak when disassembling the closed circuit breathing apparatus and lead to chemical burns Avoid skin contact Wear protective gloves and goggles In case of eye cont...

Страница 17: ...th release levers 1 Swivel the spring bridge 90 and remove it from the closed circuit breathing apparatus 2 Release the locking mechanisms between the CO2 absorber and breathing bag as well as between...

Страница 18: ...4 Prepare the CO2 absorber Dispose of the disposable absorber For the refill absorber remove the soda lime and the two non woven mats and discard them The sieve can be reused after disinfection 5 2 3...

Страница 19: ...rmation 5 2 5 Assembling the closed circuit breathing apparatus 5 2 5 1 Overview 1 Install the CO2 absorber see Installing the CO2 absorber page 19 2 Install the breathing air cooler see Installing th...

Страница 20: ...nect the red medium pressure hose to the breathing air cooler The quick connect coupling must engage When connecting make sure that a click is heard If necessary pull on the hose and check whether the...

Страница 21: ...th the locking mechanisms to the CO2 absorber and breathing air cooler Every locking mechanism has two lock buttons with engagement hooks Ensure the locking mechanisms on the CO2 absorber and breathin...

Страница 22: ...en the Connect ECU on the shoulder strap 5 2 6 Testing the closed circuit breathing apparatus 5 2 6 1 Notes for testing The following test sequence applies for both apparatuses with constant oxygen do...

Страница 23: ...he selector switch on the test unit to 2 Tightly pinch the exhalation hose with your hand Use the face spanner from the BG ProAir Test Set if necessary 3 Pump once The test unit must display at least...

Страница 24: ...ically turns on and runs a self test 3 Briefly press the bypass button Oxygen must be heard to flow into the circuit flow noise 5 2 6 13 Checking the minimum valve 1 Set the selector switch on the tes...

Страница 25: ...b 400 when handling the CO2 absorber WARNING Reduced period of use possible If the expiration date of the soda lime is exceeded the intended period of use for the apparatus may not be reached Note the...

Страница 26: ...s are shown on the display 7 Confirm the battery type 8 Turn off the Connect ECU 6 Transport Condensate forms in the breathing circuit during use After use transport the closed circuit breathing appar...

Страница 27: ...5 L min Bypass 80 L min Minimum valve 80 L min Temperature during continu ous use1 1 according to EU type examination 6 C to 30 C Air pressure 900 hPa to 1200 hPa Relative humidity 0 100 Storage temp...

Страница 28: ...ylinder 2 200 O2 CGA USA R360395 BG ProAir 2 200 O2 Configurator R360560 Accessories Dr ger FPS 7000 RP R56326 Dr ger FPS COM 5000 R62700 klar pilot anti fogging spray R56542 BG ProAir disposable abso...

Страница 29: ...tightness test with positive pressure Lower pressure to 7 0 5 mbar Press OK button Pressure difference 1 mbar min Engage lever in spring bridge Pump to activate Opens between 4 and 8 mbar Relief valve...

Страница 30: ...e pressure Lower pressure to 7 0 5 mbar Press OK button Pressure difference 1 mbar min Relief valve Engage lever in spring bridge Pump to activate Opens between 4 and 8 mbar Bypass Open cylinder Brief...

Страница 31: ...Annex Instructions for use Dr ger BG ProAir 31...

Страница 32: ......

Страница 33: ......

Страница 34: ...9300708H Manufacturer Dr ger Safety AG Co KGaA Revalstra e 1 D 23560 L beck Germany 49 451 8 82 0 9300708 1114 800 en Dr ger Safety AG Co KGaA Edition 01 2021 10 Subject to alterations www draeger com...

Отзывы: