4.5 Connecting the gas 

 

Before  making  any type of connection, ensure that the type of gas 

and  pressure 

of  the  supply

  for  which  the  equipment  has  been  calibrated 

corresponds to the type and the pressure of the gas that is available. This 
is indicated on the initial regulation label applied to the identification plate. 
Should  these  not  correspond,  refer  to  paragraph  8.4  to  change  the 
regulation. 

 

Gas  appliances  have  a  gas  input  with  a  G1/2

  conic  thread  as 

indicated in the specifications. The connection to the building’s gas supply 
must be made by means of metallic tubing in zinc plated steel or in copper, 
exposed to view.  

The  equipment  must  be  connected  to  the  gas  mains  supply  with  an 

easily operated mains tap.   

The  connection  of  the  tubing  to  the  equipment  must  be  made  with  a 

three piece metal joint to facilitate disassembly. 

The strength of the gas tightness on the threaded joint must be ensured 

with  materials  specifically  declared  to  be  suitable  by  their  manufacturer 
also for methane and GPL gasses.   

4.6 Emissions from Cooking Appliances 

This  oven  produces  waste  gasses  classified  as  type  “A”  (see 

Tab. 3.1): equipment not intended for connection to a chimney or flue 
or  a  device  for  the  evacuation  of  the  combustion  residue  into  the 
open  air  from  the  room  in  which  the  equipment  is  installed.  The 
drawing  in  of  combustion  air  and  the  expelling  of  combustion 
exhaust takes place in the room where the oven is installed.    

 

To install type “A” equipment, rooms in which it is housed must 

be  aerated  and  ventilated.  They  must  specifically  respect  the 
conditions  concerning  the  flow  of  air  necessary  for  combustion  and 
aeration of these spaces and for the disposal of combustion residue.   

 

 

 

  ATTENTION!  Proceed  with  the  installation  according  to  those 

norms  in  force  for  this  type  of  oven  in  the  country  where  it  is  being 
carried out. For further information consult these norms.   

 

To find out the nominal heat input of your oven, see Tab 3.1.  

Содержание ASADOR G

Страница 1: ...Fax 39 045 8581455 Web www zanolli it e mail zanolli zanolli it ASADOR G Manuale di installazione uso e manutenzione Manual for installation use and maintenance Manual de instalaci n uso y manutenci n...

Страница 2: ......

Страница 3: ......

Страница 4: ...Dr Zanolli s r l Via Casa Quindici 22 37066 Caselle di Sommacampagna VR Tel 39 0458581500 Fax 39 0458581455 VAT N IT00213620230...

Страница 5: ...ectrical connection 13 4 5 Connecting the gas 15 4 6 Emissions from Cooking Appliances 15 4 7 Checking before starting work 16 5 FUNCTIONING AND USE 17 5 1 Preparing the rotisserie for use 17 5 2 Turn...

Страница 6: ...stainless steel both in the casing and in the cooking chamber ensures extremely easy cleaning and a long working life to the product even with its repeated use for cooking foods with a high level of s...

Страница 7: ...ly and quickly consulted The manual must accompany the equipment if it is resold as it cannot be considered complete and safe without it Take note of the code shown on the back cover In the event that...

Страница 8: ...ion necessary for the cleaning of the equipment all those operations that must be carried out by the user to guarantee that it continues to function under safe conditions above all those concerning hy...

Страница 9: ...ve 1935 2004 CE Regulation for Equipment intended to come into Contact with Foodstuffs 3 3 Use intended for the product ASADOR rotisserie are designed for cooking various types of meat and fish of sma...

Страница 10: ...imum Power 5 9 kW 11 8 kW 17 7 kW 23 6 kW 35 4 kW 47 2 kW Reduced Power 3 kW 5 9 kW 8 9 kW 11 8 kW 17 7 kW 23 6 kW Number of burners and jets 1 2 3 4 6 8 PREPARATION G20 Maximum capacity 0 624 m3 h 1...

Страница 11: ...ices 4 1 Checking on delivery Unless otherwise agreed the products are carefully packaged in a robust structure in wood and with a sheet of nylon bubble wrap giving protection against knocks and humid...

Страница 12: ...urations with feet for placing on table or worktop with trestle in stainless steel complete with wheels with warming cabinet A plug for the power cable is not supplied together with the other componen...

Страница 13: ...damage to the ceiling of the area where it is housed caused by hot oily fumes If the rotisserie is supplied with feet it should be placed on a work surface being of a suitable height and strong enough...

Страница 14: ...failure to observe the norms in force for the installation of gas equipment During the installation care must be taken to avoid obstructing the cooling vents and the air intakes for combustion air bui...

Страница 15: ...the power supply required by the apparatus itself see Tab 3 1 The appliances are supplied with an electric connection with ground earth cable for connecting the appliance to the power grid according t...

Страница 16: ...t must be easily accessible and must not require further location after the installation of the equipment The distance between the equipment and the socket must be sufficient to avoid stretching the p...

Страница 17: ...th of the gas tightness on the threaded joint must be ensured with materials specifically declared to be suitable by their manufacturer also for methane and GPL gasses 4 6 Emissions from Cooking Appli...

Страница 18: ...n of a forced aeration system depending on the norms in force in the country where the installation is being made for ovens with a type A exhaust Be aware of the total thermal input of the ovens house...

Страница 19: ...that control each burner are on the right side of the rotisserie corresponding to the position of each spit To light the gas position a naked flame near to the burner and rotate the knob in an anticlo...

Страница 20: ...eft end into the square seat of the turning mechanism and rest it on the supporting bush Ensure that the dripping tray is positioned at the bottom of the cooking bay 5 5 Removing the spits Attention W...

Страница 21: ...urity systems of the rotisserie in a good state The use of the upper part of the rotisserie as a shelf or storage surface is prohibited Do not introduce inflammable materials into the rotisserie or us...

Страница 22: ...um coated sheet steel cooking chamber and the coated or chromed parts use a soft moistened sponge and if needs be a weak non abrasive detergent Rinse and dry with a soft clean cloth If there is a cons...

Страница 23: ...n be found between the various burners element groups and is extractable to facilitate easy cleaning to be carried out according to the instructions below Lift the lower part of the burner protection...

Страница 24: ...an easily ascertain that it has been disconnected during all of the work done with the guards removed 8 1 Removing the fixed side protection Before removing any fixed protection check that the equipme...

Страница 25: ...ntended for use by maintenance instructions are intended only for a staff qualified for the installation and maintenance of electrical and gas equipment Maintenance by other persons may cause damage t...

Страница 26: ...Repeat the procedure for each burner 8 Once this operation is finished check that there are no leaks and close the panel with its screws ATTENTION After changing the gas supply it is necessary to regi...

Страница 27: ...NTENANCE ASADOR 5G 10G 15G 20G 30G 40G 25 Turn it in a clockwise direction to decrease the power or in anticlockwise direction to increase it 3 When regulation has been completed put back the knob Fig...

Страница 28: ...20G 30G 40G 26 8 4 Exploded Diagrams Exploded diagrams of the equipment are shown below with reference to each component making it simpler to find the cause of faults and if necessary to substitute d...

Страница 29: ...8 MAINTENANCE ASADOR 5G 10G 15G 20G 30G 40G 27 Fig 8 5 Transmission...

Страница 30: ...8 MAINTENANCE ASADOR 5G 10G 15G 20G 30G 40G 28 Fig 8 6 Glass Fig 8 7 Spits and forks...

Страница 31: ...E ASADOR 5G 10G 15G 20G 30G 40G 29 Fig 8 8 Fig 8 8 Spit burner group 8 5 Wiring diagram Wiring diagram in use with all the Asador G models Fig 8 9 Wiring diagram for the connection of 230V 1N 50Hz ele...

Страница 32: ...ens are made up of the following materials stainless steel coated steel glass ceramic material rock wool and electrical parts For the purposes of demolition therefore the materials have to be separate...

Отзывы: