background image

Settings

You can edit your personal information in “user information”. Making advanced settings on Date/Time, 
key keep, heart beat beep and hour display mode is achieved in “Device settings”. You can also obtain the 
device information from here when your Dr. Trust device is in connection with your smart phone or your 
tablet.

Information

This aspect of the app provides 

indicator of blood pressure readings as 

by World 

Health Organisation, ECG summary results and app version.

Help

It provides the user with instructions of establishing connection between your DR. Trust device and your 
tablet or smartphone.

About

It enriches the user with the information of BP monitor app developer.

9. CLEANING AND MAINTENANCE

Please clean the surface of the ECG Pen with a soft cloth dampened with water.

If the electrodes are dirty, please use a soft cloth or a cotton swab moistened with disinfectant alcohol to 
clean dirt from the surface.

Connect device

 

Turn on the auto scan function on your app

 

Select your Dr. Trust device to establish connection.

 

Bluetooth would light on once it is successfully connected.

10. MESSAGES & TROUBLE SHOOTING

Message Shown                         Possible Cause                         Suggestion

Measurement result shows

t Rate.

Unstable or weak ECG signals.

Please retake the measurement

following the manual's 
instruction.

Measurement result shows

       EE.

Failure  analysis  resulted  from 
either  low  contact  pressure  or 
h i g h   n o i s e   l e v e l   d u r i n g 
measurement.

Please retake the measurement
following the manual's 
instruction.

Problem                                             Possible Cause                                           Suggestion

Power does not come on

      after pressing the power
      button for 3 seconds.

1. Battery power is low.
2. Batteries are installed with
    wrong direction.

1. Replace with new batteries.
2. Make sure the polarities of 
batteries are matched with the 
ones indicated on the battery 
compartment.

Electrode touching 

       skin, but measurement
       does not start.

Pressing too lightly.

Make sure to press the bottom
electrode down enough.

Measurement records

disappear from the device
storage.

Old records are overwritten by new
ones due to storage overload.

Download data periodically to 
your computer for record
keeping.

    Bluetooth c

failed.

Basic communication problem 
between the device and 
Smartphone/Pad.

Please  turn  off  the  device,  “Dr 

Trust  iBP  Monitor”  APP  and 

B l u e t o o t h   f u n c t i o n   o f 

Smartphone/Pad, then follow the 

instructions mentioned above to 

reconnect again.

17

16

Содержание ECG PEN

Страница 1: ...e by providing with the most trusted and innovative health care and wellness products Being a renowned global leader in health care products Dr Trust ensures that our technically efficient team works dynamically and tirelessly to provide the best of the medical devices to our clients The products that we havetoofferaresuitablydesignedforuseathomes laboratoriesandhospitals Our ground breaking solut...

Страница 2: ...ement 6 Taking Measurement 7 Result Display 8 iBP Monitor APP 3 3 4 5 7 8 13 14 9 Cleaning and Maintenance 10 Messages and Trouble Shooting tions 12 EMC Information 13 Customer Support 16 17 18 19 25 1 SYMBOL DEFINITIONS 2 GENERAL NOTES 1 ThisisanElectrocardiogram ECG devicethatprovidesreferentialdatathatcouldbetakeninto considerationbymedicalprofessionals 2 TheappliedpartisECG 3 Selfdiagnosisortr...

Страница 3: ...Donotstore exposethedeviceinthefollowingenvironments Locationsexposedtodirect sunshine hightemperatureorhumidity heavydirt nearwateror e andunderhighelectro magnetic Storethedeviceinsafeplacetoavoidsmallpartsswallowedbychildrenunderanycircumstances Static electricity may cause damage to the electronic components to preventelectrostaticdamagetothe device grounding yourself to discharge the static e...

Страница 4: ... Digits Display a Shows the sequence number of the measurement results stored in memory b Shows the 30 second count down during measurement 5 Time Shows date and time 6 Bluetooth Connection Displays the status of Bluetooth connection 5 PREPARATION BEFORE TAKING MEASUREMENT To charge your ECG Pen please follow the steps below 1 Remove the battery cover by inserting the tip of y er 2 Follow the posi...

Страница 5: ...of each individualuser Ifitisnotpossibletotakestablemeasurementsusingagivenmeasurementmethod this could have a harmless cause such as the shape of the heart However the cause may also be an illness or disease Measurement method C offers maximum comfort but offers a much lower measurement stability than methodsAorB Presstheon offbuttonforaboutthreesecondstoturnthedeviceon Thedeviceshowsthefulldispl...

Страница 6: ... against your chest until you hear or feel a click Important Do not exert excessive pressure on the electrodes with y Important Do not pr our skin Measurement method C left hand right hand approximately corresponds to lead 1 Place y wo upper electrodes on the device our left hand on the lower electrode Press the lower electrode until you hear or feel a click Important Do not pr our skin Please not...

Страница 7: ...lding ECG Pen in the wrong direction 7 Result Display Normal Result Slow Heart Rate 60 bpm Fast Heart Rate 100 bpm Paused Heart beat pause 2 s Irregular Rhythm Disrupted Rhythm Abnormal Waveform Altered Waveform Please note that if the displayed heart rate is it indicates ECG signals are unstable or weak Pleaseretakethemeasurement Measurement Results The possible results are shown below 13 12 ...

Страница 8: ...dGoogleplaystoresforandroidusers Downloading the app You can connect IBP monitor app with your Dr Trust ECG Pen devices using Bluetooth 4 0 It helps in providing real time display of ECG and blood pressure measurements The app also automatically stores recordsonsmart phoneortabletforfurtherdiagnosis QR code scanning Application Interface Measure Using the measure feature ECG and blood pressure can...

Страница 9: ...e Shown Possible Cause Suggestion Measurement result shows t Rate Unstable or weak ECG signals Please retake the measurement following the manual s instruction Measurement result shows EE Failure analysis resulted from either low contact pressure or h i g h n o i s e l e v e l d u r i n g measurement Please retake the measurement following the manual s instruction Problem Possible Cause Suggestion...

Страница 10: ...nitor APP Problems of data exchanging for tion If the device is discovered successfully there will be a blank on the box then click on the blank to manually link the device with APP and display the device ID 11 SPECIFICATIONS 12 EMC INFORMATION 19 18 ...

Страница 11: ...21 20 ...

Страница 12: ...bserved to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating theDr TrustECGPen Recommended separation distances between portable and mobile RF communications equipment and the Dr Trust ECG Pen The Dr Trust ECG Pen is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled T...

Страница 13: ...umoutputpowerratingofthetransmitterinwatts W accordingto thetransmittermanufacturer NOTE1At80MHzand800MHz theseparationdistanceforthehigherfrequencyrangeapplies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorptionandr tionfromstructures objectsandpeople COPYRIGHT 2018 DR TRUST ALL RIGHTS RESERVED www drtrustusa com dr drtrustusa com drtrust ...

Отзывы: