background image

 

25 

 

e.

 

Wi-Fi  rebinding  (When  Wi-Fi  password  changes  or  network 

configuration changes) 

Press 

  for 10 seconds, 

  will be flashing slowly for 60 seconds. 

Then 

  will be off. The original binding will be removed. Follow step 

above for rebinding. 

 

Remarks: Please make sure the router is configured at 2.4GHz.

 

 

Содержание DR-1100HP

Страница 1: ......

Страница 2: ...ION 3 III FEATURES 4 IV ACCESSORY 4 V TECHNICAL PARAMETERS 5 VI DIMENSION 6 VII INSTALLATION INSTRUCTIONS 7 VIII OPERATION INSTRUCTIONS 13 IX STARTING 15 X MAINTENANCE 16 XI TROUBLESHOOTING 18 XII WI...

Страница 3: ...al conditions such as noise smell smoke or electrical leakage please switch off the machine immediately and contact the local dealer Don t try to repair it by yourself 5 Don t use or stock combustible...

Страница 4: ...ing the heat pump 1 This product is only for heating swimming pool or spa water It cannot be used for other applications 2 Inlet and outlet water nozzles are not designed to bear the weight of externa...

Страница 5: ...the local dealer installer 11 Do not attempt to repair the heat pump yourself II Application 1 Set swimming pool water temp efficiently and economically to provide you comfort and pleasure 2 The user...

Страница 6: ...o low or no water flow 4 Exceeding low temperature auto stop protection 5 Temperature control forced defrosting 6 International brand compressor 7 High efficient titanium heat exchanger 8 Easy install...

Страница 7: ...ormance Condition Air 80 F 27 Water 80 F 27 Humidity 63 Heating capacity Btu 61 500 85 000 104 000 Heating capacity Btu in silence mode 49 200 68 000 83 500 C O P 9 9 5 35 12 3 5 7 12 2 5 6 Performanc...

Страница 8: ...ithout notice A B C D E F G H DR 650HP 15 6 23 2 15 4 16 5 37 8 14 2 2 9 25 9 DR 900HP 15 6 28 3 15 4 16 5 43 0 24 4 2 9 37 7 A B C D E F G H DR 1100HP 36 3 17 6 35 6 37 2 27 8 20 9 3 3 38 5 BF E C H...

Страница 9: ...in a sealed system ONLY trained and qualified service personnel are authorized to install or service this equipment Without proper training and knowledge of such equipment any attempt to install or s...

Страница 10: ...e sensor for temperature automation control a Install wires from the automation controller for Heat on the terminal strip inside the heat pump s electrical compartment on the side of the heat pump b R...

Страница 11: ...End users are not qualified to install the heat pump Damage may occur to the heather or threaten the safety of the user Notes 1 The inlet and outlet water unions of this machine can t support the weig...

Страница 12: ...d to prevent re circulation of air We recommend not placing the unit underneath eaves decks or porches as this causes re circulation of discharged air thereby reducing the efficiency of the heat pump...

Страница 13: ...11 the base Place the drainage nozzle into the condensation outlet and attach it securely then contact a drainage pipe from it to the drain DR 650HP DR 900HP DR 1100HP...

Страница 14: ...l installation technician and follow the circuit diagram 4 Set leakage protection device according to the local code for wiring leakage action current 30mA specification 5 The layout of power cable an...

Страница 15: ...en lock Only after screen is unlocked any other buttons can be functioning a If no button is used within 30 seconds the screen will lock automatically At this point the backlight will turn off and 0 w...

Страница 16: ...press UP or DOWN to display or adjust the set temperature To change from Fahrenheit to Celsius press the UP and DOWM together for 5 seconds 3 Smart Silence mode selection Smart mode as default will be...

Страница 17: ...5 Wi Fi setting Please kindly check the last page IX Starting A The user should start the pool pump and check for any leakage of water Power on and press the ON OFF button on the heat pump and set a s...

Страница 18: ...Cold Weather Operation In the off season when the pool is not going to be used at all 1 Cut off the power supply to avoid damage to the heat pump 2 Drain water from the heat pump by removing the pipi...

Страница 19: ...entire heat pump and pipe connections according to the pipe connecting drawing B Check the electric wiring according to the electric wiring diagram and grounding connection C Make sure that the main...

Страница 20: ...e fuse Circuit breaker tripped Turn circuit breaker back on Heat pump runs but not heat Air inlet blocked Remove obstructions Air outlet blocked Remove obstructions 3 minute protection Please wait mor...

Страница 21: ...er communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Heating Evaporator coil pipe temp sensor failure 12 P5 G...

Страница 22: ...20 XII Wi Fi setting 1 APP Download Android mobile please download from iPhone please download from 2 Account registration a Registration by Cell phone number Email...

Страница 23: ...21 b Cell phone number registration 3 Create a family account Please set a name for family and choose the room of device...

Страница 24: ...phone b Press for 3 seconds after screen unlock will be flashing rapidly to enter Wi Fi binding status c Click Add Device wait for the app to search for the device and then click add then follow the...

Страница 25: ...e flashing rapidly to enter Wi Fi binding status b Click Add device follow instructions below to finish binding display on the screen once Wi Fi connection success Note 1 After allowing the APP to loc...

Страница 26: ...Click Add device follow instructions below to finish binding display on the screen once Wi Fi connection success Note If it doesn t jump automatically click Confirm hot spot connection next d If conn...

Страница 27: ...nges or network configuration changes Press for 10 seconds will be flashing slowly for 60 seconds Then will be off The original binding will be removed Follow step above for rebinding Remarks Please m...

Страница 28: ...are for heat pumps with heating function only More share device Indicate the status of Heating Compressor running percentage The current swimming pool water temp Setting temp Cloud Timer Switching C F...

Страница 29: ...hare devices to your family members After binding if your family members also want to control the device Please let your family members register the APP first and then the administrator can operate as...

Страница 30: ...28 Then your family members can log in as below Notice 1 The weather forecast is just for reference 2 APP is subject to updating without notice...

Страница 31: ...ringing top quality alternative supplemental heating products to our customers How long is the warranty This heater comes with a THREE YEAR LIMITED COMPONENT WARRANTY If your unit does not appear to b...

Страница 32: ...er pool heat pump The factory reserves the final interpretation right And keep the right to stop or change product specification and design without prior notice at any time no need to bear the resulti...

Отзывы: