15
4.
Defrosting
a.
Auto Defrosting:
When heat pump is defrosting, HEATING
will continually
flashing. After defrosting, HEATING
will stop flashing.
b.
Manual Defrosting:
When heat pump is heating, press FAN
and MINUS
together for 5 seconds to start manual defrosting,
will flash continuously. After
defrosting, HEATING
will stop flashing.
(Note: Manual defrosting intervals should be more than 30 minutes and the
compressor should run for more than 10 minutes.)
5.
Wi
-
Fi setting
Please kindly check the last page.
IX
.
Starting
A.
The user should start the pool pump, and check for any leakage of water; Power
on and press the ON/OFF button on the heat pump, and set a suitable
temperature at the thermostat.
B.
In order to protect the heat pump, the heat pump is equipped with a time
-
delay
starting function. When starting the heat pump, the blower will run for 1 minute
before than the compressor.
C.
After the heat pump starts up, check for any abnormal noise from the heat pump.
NOTE:
The user must start the pool pump before the heat pump, and turn off the
heat pump before the pool pump, or the heat pump will be damaged.