Options for protection devices and cable specifications
※Above data is subject to modification without notice.
Note:
The above data is adapted to power cord ≤ 393.7 inch. If it is >393.7 inch, wire
diameter must be increased. The longest signal cable can be extended to 1968.5 inch.
4.
Installation and Requirements
The heat pump must be installed by a pool professional. End users are not qualified to
install the heat pump. Damage may occur to the heather or threaten the safety of the
user.
Notes:
1)
The inlet and outlet water unions of this machine can’t support the weight of the
external piping. The heat pump must be connected with hard pipes!
2)
The piping between pool and the heat pump should be less than 10m, or its
performance cannot be ensured.
Model
DR-650HP
DR-900HP DR-1100HP
Breaker
Rated Current (A)
20
26
40
Rated Residual Action Current
(mA)
30
30
30
Fuse (A)
20
26
40
Power Cord (AWG)
3×11
3×10
3×8
Signal cable (AWG)
3×20
3×20
3×20