![Dr. Escherich AIFUN-CLEAN Spot 110 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/dr-escherich/aifun-clean-spot-110/aifun-clean-spot-110_operating-instructions-manual_2525971029.webp)
- 28 -
Operating Instructions for TAIFUN CLEAN
www.dr-escherich.com
Version 12/09
Description
Typ lt.
Best. Nr.
Rotation nozzle TAIFUN-CLEAN 04 / 014 Compact 180
TCR7A130
E090
Rotation nozzle TAIFUN-CLEAN 04 / 014 EX
TCR7A130EX
E106
Rotation nozzle TAIFUN-CLEAN Compact 140
TCR7A95
E111
Rotation nozzle TAIFUN-CLEAN Compact 140 EX
TCR6A95EX
E117
Rotation nozzle TAIFUN-CLEAN Compact 240
TCR7A190
E118
Rotation nozzle TAIFUN-CLEAN Compact 240 EX
TCR6A190EX
E119
Rotation nozzle TAIFUN-CLEAN 05 EX
TCR7A70EX
E124
Rotation nozzle TAIFUN-CLEAN 05/015/ Spot 110
TCR7A70
E123
Adapter f. ETC04/014, M27/M20, length 57mm
663-4500-005-
E359
Adapter f. ETCC, M27 auf M20, length 42mm
663-4400-008-
E377
Key for rotation nozzles ETCR6 and ETCR7
TCK7
E385
INSTALLATION INSTRUCTIONS FOR TAIFUN-CLEAN DEVICES
OPERATING INSTRUCTIONS
Observe the instructions, particularly the safety instructions, in the operating instructions.
Use filter regulating valve
Required pressure compressed air quality class 3 (conforming to standard DIN ISO 8573-1)
Max. oil capacity: 1 mg/m
3
Max. residual dust content: Particle size 5µm, particle concentration 5 mg/ m
3
Max. residual water content: 0.88 g/ m
3
, pressure condensation point: -20°C
Max. air pressure
Observe data on the rotation nozzles and in the operating instructions!
Keep hoses as short as possible!
Avoid constrictions
No kinks, no reduced radii smaller than 3 x hose diameter
Do not use quick-fit connectors (bottleneck)