Operating Instructions for TAIFUN CLEAN
www.dr-escherich.com
Version 12/09
When all cables and hoses are correctly fitted:
1. Switch on supply unit for the ionizers.
2. Switch on compressed air supply and set to operating pressure.
Operating pressure of the rotation nozzles may not exceed the max.
permitted air pressure (Table 2)! If the max. pressure is exceeded,
damage to components can occur! In this case the guarantee on the
rotation nozzles becomes invalid!
3. TAIFUN-CLEAN 012, 014, 015
:
Switch on suction system. Optimise
suction efficiency by adjusting distance of the device from the material
surface (via device mounting), the compressed air via the filter regulating
valve and/or the flow rate via the throttle valve on the radial ventilator.
5. Start-Up