Only when all components are de-energised!
7.1 Regular Servicing
The device must not come into contact with dampness, wetness or aggressive
media!
Use test meter type H203 to check the function of the ionization rods regularly
and above all after cleaning! Only qualified personnel may clean the ionization
rods!
Ionization rods must be cleaned as needed, but at least every two weeks using
special cleaning fluid type H031 and special cleaning brush type H032.
The TAIFUN-CLEAN unit should be cleaned when dirty as necessary.
Check firm seating of the rotation nozzles in the TAIFUN-CLEAN profile only
with the special tool TCK7. Place the tool on the rotor and turn in a clockwise
direction, until the rotor is hand-tight. Check the rotor seating regularly (s.
Maintenance Plan).
Service Item
Service Intervals
Clean ionizers
As required min. 2 weeks
Check function of ionizers
As required min. 2 weeks
Check rotation nozzles
As required min. 4 weeks
Clean TAIFUN-CLEAN device
As required min. 4 weeks
Tab. 6