The red LED
When the red LED lights up, the driving machine is in the excessive temperature field. In this case, the
driving machine will stop. Wait till the driving machine cools down and start it again by means of the green
button on the Powerbox.
The red LED also lights up if there is a fault; in this case, the driving machine stops. This usually happens
in case of suddenly occurring very high overload (seizure). Therefore the driving machine will be switched
off for machine safety reasons. The red LED goes off when the machine is turned on again with the green
button and the green LED indicates that the machine is again operational (reset-function).
PB WX8/10 and PB WX8/10 VB Powerbox:
In case of sudden hazard, the system may be switched off by pressing the
emergency stop button, located near the handle. This operation may also be
performed by a third person; for this reason, always place the Powerbox at
some distance from the place of work.
After you have finished your work, switch off the system by means of the red
button.
If the red LED does not go off and the green LED does not light up either, there is a fault at the Powerbox
or at the driving motor. Contact an authorized workshop.
5.4 Automatic overload cut-off
As already described under 4.3, the machine automatically stops in case of persistent overload. The
resetting process is initiated by a new actuation of the green button.
6.0
Safety instructions
Important
Only use the tools under supervision. Disconnect the mains plug and check
that the switch has been turned off,
-
when the tools remain unsupervised,
-
during setup and disassembly works,
-
in case of voltage drops (PB WX8/10, below 340V),(PB WX2, below 200V),
-
in case of uneven mains voltage (phase dissymmetry) or interruption of a phase (phase failure),
-
for adjusting or fitting an accessory.
Switch off the machine if it stops for any reason. This will prevent its sudden starting when unsupervised.
Do not use the machine if
-
a part of the casing is missing or defective,
-
the switch, lead or plug connector has suffered damage (conduct a visual inspection every day!),
-
when operating the equipment, no cooling water may penetrate into the electrical components in
any position of employment,
-
if water drips out of the tool, stop working and have the tool inspected by an authorized service
workshop,
-
after a fault, switch it on again only when the saw blade or the core bit can be turned easily
-
Check the working area with a line detector to prevent cutting through electric cables, water or
gas lines, etc.