![DPS Telecom Site Dialer G3 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/dps-telecom/site-dialer-g3/site-dialer-g3_user-manual_2525744008.webp)
3
Specifications
3
Hardware
Dimensions:
1.72"H x 17"W x 6.64"D
Modem:
33.6K, Cellular
1
Mounting:
19” or 23” rack or wall mount
Weight:
3.8 lbs. (1.72 kg)
Discrete Alarm Inputs:
N/A
2 Discrete Alarm Length:
N/A
Power Input:
Dual -48VDC power feeds (-36VDC to -60VDC)
Analogs:
N/A
Input Range:
N/A
4 Analog Accuracy:
N/A
Control Outputs:
N/A
Max Voltage:
N/A
3 Current Draw:
350mA @ -48 VDC
Max Current:
N/A
Fuse:
Dual 3/4 Amp GMT
1 Power Outputs:
N/A
Voltage Output
Options:
N/A
Operating Temp:
32° to 140°F (0° to 60°C)
Output Current:
N/A
1 Industrial Operating Temp:
-22° to 158°F (-30° to 70°C)
Output Fuse:
N/A
Storage Temp:
N/A
Operating Humidity:
0% to 95% (non-condensing)
Audible Interfaces:
N/A
Visual Interfaces:
12 LEDs
MTBF:
60 Years
RoHS:
5/6
1 Hardware Interfaces:
1 RJ45 10/100BaseT full-duplex Ethernet port
1 USB
5
debug/craft port
Ordering Options:
N/A
1 RJ11 Telco jack
Software
Downloadable
Firmware:
Yes
1 D-Wire Sensor Support:
N/A
Built-in Web Interface:
Yes
Browser Support:
IE9, IE10, Firefox, Chrome...
Ping Alarms:
N/A
Protocols:
DCPx, TELNET, HTTP, Email….
SNMP Support:
V1, V2C, V3
OS Support:
XP, Vista, 7 (32 or 64 bit)
Note:
1 Valid if hardware option is included.
2 Minimum lengths determined with TTL voltage level alarms. Actual distance may vary.
3 Current measured at rated voltage with all controls latched and all alarms triggered.
4 See analog section in manual for detailed analog accuracy breakdown.
5 We always recommend checking for ground potentials before using the USB port and suggest using a USB isolation device for additional protection. Without USB isolation,
ground potentials can damage your computer and/or equipment and adversely impact warranty coverage.
* This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Содержание Site Dialer G3
Страница 3: ......
Страница 13: ...8 5 Select Save...
Страница 24: ...19...
Страница 46: ...41...
Страница 47: ...42...