manualshive.com logo in svg
background image

USER MANUAL

Site Dialer G3

April 12, 2016

D-UM-SDXMV

Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs.

(SDXMV-12004)

Содержание Site Dialer G3

Страница 1: ...USER MANUAL Site Dialer G3 April 12 2016 D UM SDXMV Visit our website at www dpstelecom com for the latest PDF manual and FAQs SDXMV 12004...

Страница 2: ...d transmitted or used to make a derivative work by either mechanical electronic or any other means in whole or in part without prior written consent from DPS Telecom except as required by United State...

Страница 3: ......

Страница 4: ...r Job 6 1 9 Step 2 Setup the Site Dialer RTU Job 6 2 10 Step 3 Create the Site Dialer Device 6 3 10 Step 4 Setup Pager Carriers 6 4 11 Step 5 How to Setup Pager Schedules 6 5 11 Step 6 How to Setup Pa...

Страница 5: ...2 33 Device Access Menu 10 34 Reference Section 11 35 Updating Site Dialer G3 Firmware 11 1 35 Updating T Mon Software 11 2 36 System Alarms Map 11 3 37 Technical Support 12 38 T Mon Gold and Platinum...

Страница 6: ...Get the important notifications you need no matter where you are via text to speech voice alerts The Site Dialer G3 itself is easy to install and requires virtually no configuration After physically s...

Страница 7: ...and call DPS Telecom at 800 622 3314 Site Dialer G3 Site Dialer G3 Resource CD D PK SDXMV 12004 X1 Site Dialer G3 UM 6 ft USB Craft Port Cable D UM SDXMV D PR 046 10A 06 X1 X3 Ethernet Cable 14 ft Thr...

Страница 8: ...Support XP Vista 7 32 or 64 bit Note 1 Valid if hardware option is included 2 Minimum lengths determined with TTL voltage level alarms Actual distance may vary 3 Current measured at rated voltage with...

Страница 9: ...sh or rear mounted WARNING Leave one rack unit vacant above the Site Dialer G3 to provide adequate heat ventilation Site Dialer G3 mounts in a 19 rack or a 23 rack using the provided rack ears for eac...

Страница 10: ...have been made 2 To ground Site Dialer G3 connect a grounding wire to the grounding lug 3 Remove the power connector plug from Power Connector A Note that the plug can be inserted into the power conn...

Страница 11: ...into the Site Dialer G3 s LAN port 2 Look up your PC s current IP address and subnet mask and write this information down 3 Reset your PC s IP address to 192 168 1 200 Contact your IT department if yo...

Страница 12: ...ce 3 In the left frame you will see the Monitor menu blue Provisioning menu green and Device Access menu pink The Monitor menu links are used to view the current status of alarms The Provisioning menu...

Страница 13: ...8 5 Select Save...

Страница 14: ...k Ports Jobs then Job Ports 2 On the Job Ports screen select a COM port above 47 3 Under the Port Usage drop down select Voice Pager This is the job that talks to the T Mon 4 Enter a description optio...

Страница 15: ...Tcp Ports at the bottom of the container 5 Add a new TCP port with the following information a Type UDP DPS RTU SNMP Trap Processing SNMP Agent b TCP Port 2001 or any available port c Description Ent...

Страница 16: ...e Int Initials and Name for your technicians 4 For Type select Voice 5 For Pager Phone enter the phone number to call 6 The Pin field should be filled in for added security This is the ID you ll press...

Страница 17: ...to send a notification i e ALM for alarm CLR for clear or BOTH 6 Under delay enter the number of minutes you want the condition to be met before sending the notification 7 Leave Format set to 1 becau...

Страница 18: ...o include such as Alarm Status Site Name Time Date etc The message parts will be said in the order you specify 3 The Delay field specifies how much of the message is allotted to that clause If the con...

Страница 19: ...ing menu You can setup as many as 8 different notifications Begin the setup wizard by clicking Edit for a notification number In this example we ll setup Notification 1 to send emails 2 At the Notific...

Страница 20: ...nt to test the email notification you ve just setup by clicking Test next to the notification Make sure you Write your changes under Device Access before attempting a test You will prompted with a pop...

Страница 21: ...16 the image below you might assign Notification Device 1 to System Alarm 49 This means that you would receive an email notification when an alarm for System Alarm 49 NTP failed occurs...

Страница 22: ...reen you ll enter your network s SNMP settings Enter the IP address of your SNMP Trap Server Enter the Trap Port Number usually 162 and the Trap Community name The typical SNMP community string for ne...

Страница 23: ...g your alarm master to see if the SNMP trap was received NOTE This test only means that your notification settings are correct but you still need to assign the notification to an alarm point See the n...

Страница 24: ...19...

Страница 25: ...interface will then prompt you to either Write your changes to the unit or Reboot the unit for changes to take effect in the top left corner of your browser The relevant options will be highlighted i...

Страница 26: ...dian unit Optional field Location The location of this NetGuardian unit Optional field Contact Contact telephone number for the person responsible for this NetGuardian unit Optional field DCP Responde...

Страница 27: ...user profile Used for logging into web interface Status The status of the profile It can be one of the following Default Reserved for the admin account which cannot be suspended Active Indicates the...

Страница 28: ...relay commands Check to allow profile to set status of control relays to OPR RLS or MOM TTY access access via Craft port or via Telnet Check to allow profile to access the Site Dialer s TTY interface...

Страница 29: ...erver The IP you ve already assigned to the unit becomes inactive Using DHCP means the unit will NOT operate in a T Mon environment Unit IP IP address of the NetGuardian Subnet Mask A road sign to the...

Страница 30: ...notification The Notifications screen Notification Settings ID The notification s ID number Notify On Specifies when the notification is sent Possible values Disabled Alarm Clear Both Type The type of...

Страница 31: ...want to be notified about an alarm The Edit Notification screen Edit Notification Settings Status Choose when to send a notification Do not notify Notify on Alarm Notify on Clear Notify on Alarm and C...

Страница 32: ...s Displays the email address defined in the Edit menu System that the Site Dialer G3 will send emails from Not editable from this screen To E mail Address The email address of the person responsible f...

Страница 33: ...SNMP v1 v2c or v3 traps SNMPv3 User Select the user User is configured in the SNMP menu 8 4 4 Schedule The Notification Schedule screen allows you to specify which days and times the notification sho...

Страница 34: ...em Alarms screen System Alarm Settings Pnt Point The system alarm point number Description Non editable description for this System housekeeping Alarm Silence Check this box to choose to silence this...

Страница 35: ...1m 30m 0s off Web Timeout Maximum idle time allowed before the web interface will automatically logout Range 1m 30m Timed Tick This is a heartbeat function that can be used by masters who don t perfor...

Страница 36: ...current time Enable NTP Check to enable automatic time adjustment with Network Time Protocol NTP Server Address or Host Name The NTP address or host name from where you want the unit to retrieve the t...

Страница 37: ...en the alarm condition is not present Click on Alarms in the Monitor menu to see if any base alarms have been triggered System Alarm Monitoring ID Alarm ID number Description User definable descriptio...

Страница 38: ...in Old Telephone Service POTS connection Just input the phone number you d like to dial and press Call The Test Call screen Stats 9 2 This view shows various stats about the device such as bootloader...

Страница 39: ...under Device Access to perform the desired action The control menu is located in the bottom left of the web interface Device Access Backup Config Backs up the units configuration settings Read Reads a...

Страница 40: ...nd navigate to the Site Dialer G3 at http 192 168 1 100 2 Login with the default username of admin and password dpstelecom 3 Click Upload located on the top right of the page 4 Click Choose File and s...

Страница 41: ...e g http 192 168 1 100 10000 2 Login with the default username of dps_admin and password dpstelecom 3 Select Others then Custom Commands 4 Under the Upgrade Software section select Browse to select th...

Страница 42: ...on 8 failed A notification 8 event such as a page or email was unsuccessful Use RPT filter debug to help diagnose notification problems 49 NTP Failed Communication with Network Time Server has failed...

Страница 43: ...rmation when you call our Technical Support representatives can assist you in gathering it Please write the information down for easy access Please have your user manual and hardware serial number rea...

Страница 44: ...within one business day provided there are no extenuating circumstances DPS will advance replace the entire T Mon unit After receiving the new T Mon the client will ship the failed unit to DPS The uni...

Страница 45: ...old it harmless for and against any and all claims damages losses costs expenses obligations liabilities fees and costs and all amounts paid in settlement of any claim action or suit which may be asse...

Страница 46: ...41...

Страница 47: ...42...

Страница 48: ...rm Management Dependable Powerful Solutions that allow users to monitor larger more complicated networks with a smaller less trained staff www dpstelecom com 4955 E Yale Fresno CA 93727 559 454 1600 8...

Отзывы: