background image

  The MODE Setting  affects all Channels simultaneously.  If, for example, the 

factory  preset  MODE-1  is  used,  any  and  all  batteries  connected  to  the 
outputs must be the same or very similar Lead Acid Batteries. 

 

 

The  CHARGE  MODE  VALUES  AND  SETTINGS  is  selected  via  the  use  of  the 
MENU button. Follow these steps to select an alternate Charge MODE: 

 

Hold depressed the MENU Button for 3 seconds, then release. The LCD displays 
the 

CHARGE MODE

 menu. 

 

Depress/release the MENU Button again, which then displays the 

SOFTWARE 

VERSION

 menu. 

 

Depress/release the MENU Button again, which then displays the 

CHARGE 

MODE SELECT

 Menu 

 

Now, depress and hold depressed for 3seconds again, and then release the 
MENU Button to enter into the CHARGE MODE operation. 

o

 

Each depress/release of the MENU button now increments the MODE 
Number 

o

 

Stop depressing/releasing the MENU button when the desired MODE 
Number is reached 

o

 

Hold depressed for 3 seconds the MENU Select Button to select the 
new MODE setting chosen, then release to select the CHARGE MODE 
that is displayed. If this action is not performed, the function times out, 
exits and returns without changing to a new CHARGE MODE. 

 
 

CHARGE MODE VALUES AND SETTINGS TABLE

 

 

MODE 

Battery Type/Name 

Type 

AH 

Volts/Cell* 

01 

12V General Lead Acid 

Flooded 

32AH 

2.400V 

02 

12V General Lead Acid 

AGM 

32AH 

2.450V 

03 

12V General Lead Acid 

Flooded 

18AH 

2.400V 

04 

12V General Lead Acid 

AGM 

18AH 

2.450V 

05 

12V General Lead Acid  

Flooded 

10AH 

2.400V 

06 

12V General Lead Acid 

AGM 

10AH 

2.450V 

07 

12V General Lead Acid 

Flooded 

5AH 

2.400V 

08 

12V General Lead Acid 

AGM 

5AH 

2.450V 

09 

6V General Lead Acid 

Flooded 

32AH 

2.400V 

10 

6V General Lead Acid 

AGM 

32AH 

2.450V 

11 

6V General Lead Acid 

Flooded 

18AH 

2.400V 

12 

6V General Lead Acid 

AGM 

18AH 

2.450V 

13  

6V General Lead Acid 

Flooded 

10AH 

2.400V 

14 

6V General Lead Acid 

AGM 

10AH 

2.450V 

15 

6V General Lead Acid 

Flooded 

5AH 

2.400V 

16 

6V General Lead Acid 

AGM 

5AH 

2.450V 

17 

12V GEL Lead Acid 

Flooded 

40AH 

2.333V 

18 

12V GEL Lead Acid 

Flooded 

90AH 

2.333V 

19 

6V General Lead Acid 

Flooded 

225AH 

2.400V 

20 

6V General Lead Acid 

AGM 

213AH 

2.400V 

21 

6V General Lead Acid 

AGM 

220AH 

2.450V 

22 

12V Odyssey PC680 

Pure Lead 

16AH 

2.433V 

23 

12V Optima OPT-D31M 

Spiral 

75AH 

2.450V 

24 

8V General Lead Acid 

Flooded 

170AH 

2.400V 

25 

4cell Lithium – ‘Green’ 

LiFePO 

30AH 

3.650V 

26  

4cell Lithium – ‘Green’ 

LiFePO 

15AH 

3.650V 

27  

3cell Lithium – ‘ION’ 

Li+ Ion 

20AH 

4.050V 

28  

3cell Lithium – ‘Green’ 

LiFePO 

15AH 

3.650V 

29  

2cell Lithium – ‘ION’ 

Li+ Ion 

20AH 

4.050V 

30  

2cell Lithium – ‘Green’ 

LiFePO 

15AH 

3.650V 

31  

1cell Lithium – ‘ION’ 

Li+ Ion 

5AH 

4.050V 

32 

1cell Lithium – ‘Green’ 

LiFePO 

5AH 

3.650V 

Содержание Xcel 7QP-12F950P25-C00

Страница 1: ...low multi stage charging of various battery types and chemistries Printed material may not represent the latest information available Please visit our web site www DPIpower com for updates to this or other manuals Manual P N MNUL0044 A001 Rev 2 Copyright 2020 DPI IMPORTANT READ AND SAVE THIS SAFETY INSTRUCTION MANUAL KEEP IT WITH OR NEAR CHARGER AT ALL TIMES ...

Страница 2: ...0P25 C01 Wireless option is installed Charge algorithm controls BOTH voltage and current for precise charging LCD Display with Menu Select Microprocessor Controlled Fully Automatic Read Charge Voltage Amperage Errors and more in plain LCD Display Text Up to 500mA Charging Power Per Channel ...

Страница 3: ...of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to persons Do not operate this charger if it has received a sharp blow was dropped or otherwise damaged in any manner Refer to a qualified service agent Charger contains no serviceable parts If it fails during its warranty period contact your dealer to obtain a warrant...

Страница 4: ...ng into contact with eyes Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without caps carefully follow manufacturer s recharging instructions Study all battery manufacturer s specific precautions such as removing or not removing cell caps while charging and recommended rates...

Страница 5: ... of danger caused by a worn receptacle 4 SAFE GROUNDING INSTRUCTIONS Do not remove Ground Pin from charger s Power Supply AC Plug or connect to utility power via an adaptor that bypasses the product s ground pin connection The product must be grounded at all times when connected to utility power This battery charger s Power Supply must be grounded to reduce the risk of electric shock The Power Sup...

Страница 6: ...y s Negative Neg Terminal o Reversing the output connection to a battery should be avoided but will not damage the charger When connected in reverse charging will not start disconnect the charger clip connections from the battery and remake the connections o Approximately 3 seconds after connection to a battery the charger starts its Multi Stage charging process DO NOT connect more than one batter...

Страница 7: ...ODE Battery Type Name Type AH Volts Cell 01 12V General Lead Acid Flooded 32AH 2 400V 02 12V General Lead Acid AGM 32AH 2 450V 03 12V General Lead Acid Flooded 18AH 2 400V 04 12V General Lead Acid AGM 18AH 2 450V 05 12V General Lead Acid Flooded 10AH 2 400V 06 12V General Lead Acid AGM 10AH 2 450V 07 12V General Lead Acid Flooded 5AH 2 400V 08 12V General Lead Acid AGM 5AH 2 450V 09 6V General Lea...

Страница 8: ...l If the Yellow Green LEDs of a particular Channel flash Alternately then charging on that Channel only has terminated due to a Charge Error Condition Refer to the Charge Error Table for a description of the possible causes of failure Resetting a Channel Error is easy disconnect connect DC Cable to battery and or refer to charge error table MENU SELECT BUTTON Depress and hold depressed for approxi...

Страница 9: ... battery d cTOP Top Off Stage Charging battery e cFIN Float Maintenance Stage Charge finished When no battery is connected the bottom left corner of the LCD displays NoBt This corner also displays other codes when necessary and are referenced throughout this manual CHARGE ERROR TABLE LOG ERROR CODE ERROR MESSAGE ERROR DESCRIPTION POSSIBLE CAUSE REMEDY ERR05 B Cel Wrong Type Battery voltage higher ...

Страница 10: ...checks for minimum and maximum cell voltages If a fully charged cell is detected a transition to Charge Complete is done bypassing all other charge stages BULK Charge Stage also known as Constant Current High Power charge charges at a constant current or constant power rate to deliver the bulk of the charge needed Upon completion of this stage approximately 80 of total charge is delivered to the b...

Страница 11: ...ger voltage level Common Traits Applied to All Charge Stages Each Charge Stage employs the use of a Safety Timer to time out and end that stage if the stage process took too long without achieving the desired targeted results Normally each Stage ends when the charger detects that the battery has reached the proper level of charge for that stage However each Charge Stage has a preset timer that lim...

Страница 12: ...annel are displayed Multiple Chargers operating in the same vicinity can be named with Aliases and identified Read and or set the Real Time clock USING THE APP Establishing Aliases For Multiple Charger Devices Users can discover available devices and setup an alias for each device When the APP is first started press the SCAN button to list all of the currently active devices within reception range...

Страница 13: ...cCVT Constant Voltage cTOP Top Off cFIN Finished Maintenance o Channel Charge Amps and Battery Voltage are all displayed along with the colored Channel Status chart above and the values are in real time pertaining to the associated charge Channel o Channel Error text is displayed in RED below the Voltage and Current boxes o User can switch back to Device List Screen by tapping on the back arrow on...

Страница 14: ...emedy of the consumer DPI shall not be liable for any incidental or consequential damages for breach of any expressed or implied warranty on this product Except to the extents provided by applicable law any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this warranty Some states do not allow the exclusion or limitat...

Отзывы: