7.  CHARGING A RECHARGEABLE BATTERY 

 

Each  set  of  Yellow  and  Green  LEDs  on  the  front  of  the  charger  are  used  to 
indicate the charge status state for the channel associated with the set of LEDs.  

Yellow LED Flashing 

– Battery testing in progress 

Yellow LED Solid 

– Continuous charging 

Green LED Solid 

– Battery charged 

Yellow/Green LEDs flash alternately – Charge failure on that channel 

 

Multi-Stage Charge Algorithms 

There  are  up  to  8  charging  Stages!  Depending  on  the  MODE  selected,  these 
stages  are  already  preset  and  implementation  of  each  stage  will  vary  from  one 
CHARGE MODE setting to the next, dependent on the type of battery intended to 
be charged. These charge stages ‘typically’ include: 

 

 

PRE-QUALIFICATION-TEST Charge Stage: 

  Tests Lead Acid battery for sulphation by applying a low-level charge current 

and analyzes voltage and current values and rates of change to determine if 
the battery is ready to transition to the next high-power Bulk Charge Stage. 

  For Lithium cells, this stage is extremely brief and may not be annunciated. It 

checks  for  minimum  and  maximum  cell  voltages.  If  a  fully  charged  cell  is 
detected,  a  transition  to  ‘Charge  Complete’  is  done,  bypassing  all  other 
charge stages. 

 

 

BULK Charge Stage (also known as ‘Constant-Current’): 

  High Power charge, charges at a constant current or constant power rate to 

deliver the ‘bulk’ of the charge needed 

  Upon completion of this stage, approximately 80% of total charge is delivered 

to the battery 

 

 

ABSORPTION Charge Stage (also known as ‘Constant-Voltage’): 

  Charge voltage is held at a constant level to optimize the amount of energy 

the battery absorbs. 

  Charge Amperage decreases as the energy is being absorbed. 

  Termination  of  this  stage  occurs  when  the  charge  current  decreases  to  a 

preset  value.  Duration  of  this  stage  is  dependent  on  many  factors  such  as 
size, type, age, and chemistry of battery. 

  Upon completion of this stage, approximately 95% to 100% of total charge is 

delivered to the battery. 

 

 

TOP-OFF Charge Stage (also known as ‘Finish’): 

  Charger  charges  at  either  a  constant  voltage,  or  constant  current,  or  a 

combination of constant-current / constant voltage to ‘Top-Off’ the charge in 
a battery. 

  This stage employs timing based on ‘timers’ measured and recorded during 

previous charge stages, in combination with dv/dt and/or di/dt.  
 
 

Содержание Xcel 7QP-12F950P25-C00

Страница 1: ...low multi stage charging of various battery types and chemistries Printed material may not represent the latest information available Please visit our web site www DPIpower com for updates to this or other manuals Manual P N MNUL0044 A001 Rev 2 Copyright 2020 DPI IMPORTANT READ AND SAVE THIS SAFETY INSTRUCTION MANUAL KEEP IT WITH OR NEAR CHARGER AT ALL TIMES ...

Страница 2: ...0P25 C01 Wireless option is installed Charge algorithm controls BOTH voltage and current for precise charging LCD Display with Menu Select Microprocessor Controlled Fully Automatic Read Charge Voltage Amperage Errors and more in plain LCD Display Text Up to 500mA Charging Power Per Channel ...

Страница 3: ...of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to persons Do not operate this charger if it has received a sharp blow was dropped or otherwise damaged in any manner Refer to a qualified service agent Charger contains no serviceable parts If it fails during its warranty period contact your dealer to obtain a warrant...

Страница 4: ...ng into contact with eyes Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without caps carefully follow manufacturer s recharging instructions Study all battery manufacturer s specific precautions such as removing or not removing cell caps while charging and recommended rates...

Страница 5: ... of danger caused by a worn receptacle 4 SAFE GROUNDING INSTRUCTIONS Do not remove Ground Pin from charger s Power Supply AC Plug or connect to utility power via an adaptor that bypasses the product s ground pin connection The product must be grounded at all times when connected to utility power This battery charger s Power Supply must be grounded to reduce the risk of electric shock The Power Sup...

Страница 6: ...y s Negative Neg Terminal o Reversing the output connection to a battery should be avoided but will not damage the charger When connected in reverse charging will not start disconnect the charger clip connections from the battery and remake the connections o Approximately 3 seconds after connection to a battery the charger starts its Multi Stage charging process DO NOT connect more than one batter...

Страница 7: ...ODE Battery Type Name Type AH Volts Cell 01 12V General Lead Acid Flooded 32AH 2 400V 02 12V General Lead Acid AGM 32AH 2 450V 03 12V General Lead Acid Flooded 18AH 2 400V 04 12V General Lead Acid AGM 18AH 2 450V 05 12V General Lead Acid Flooded 10AH 2 400V 06 12V General Lead Acid AGM 10AH 2 450V 07 12V General Lead Acid Flooded 5AH 2 400V 08 12V General Lead Acid AGM 5AH 2 450V 09 6V General Lea...

Страница 8: ...l If the Yellow Green LEDs of a particular Channel flash Alternately then charging on that Channel only has terminated due to a Charge Error Condition Refer to the Charge Error Table for a description of the possible causes of failure Resetting a Channel Error is easy disconnect connect DC Cable to battery and or refer to charge error table MENU SELECT BUTTON Depress and hold depressed for approxi...

Страница 9: ... battery d cTOP Top Off Stage Charging battery e cFIN Float Maintenance Stage Charge finished When no battery is connected the bottom left corner of the LCD displays NoBt This corner also displays other codes when necessary and are referenced throughout this manual CHARGE ERROR TABLE LOG ERROR CODE ERROR MESSAGE ERROR DESCRIPTION POSSIBLE CAUSE REMEDY ERR05 B Cel Wrong Type Battery voltage higher ...

Страница 10: ...checks for minimum and maximum cell voltages If a fully charged cell is detected a transition to Charge Complete is done bypassing all other charge stages BULK Charge Stage also known as Constant Current High Power charge charges at a constant current or constant power rate to deliver the bulk of the charge needed Upon completion of this stage approximately 80 of total charge is delivered to the b...

Страница 11: ...ger voltage level Common Traits Applied to All Charge Stages Each Charge Stage employs the use of a Safety Timer to time out and end that stage if the stage process took too long without achieving the desired targeted results Normally each Stage ends when the charger detects that the battery has reached the proper level of charge for that stage However each Charge Stage has a preset timer that lim...

Страница 12: ...annel are displayed Multiple Chargers operating in the same vicinity can be named with Aliases and identified Read and or set the Real Time clock USING THE APP Establishing Aliases For Multiple Charger Devices Users can discover available devices and setup an alias for each device When the APP is first started press the SCAN button to list all of the currently active devices within reception range...

Страница 13: ...cCVT Constant Voltage cTOP Top Off cFIN Finished Maintenance o Channel Charge Amps and Battery Voltage are all displayed along with the colored Channel Status chart above and the values are in real time pertaining to the associated charge Channel o Channel Error text is displayed in RED below the Voltage and Current boxes o User can switch back to Device List Screen by tapping on the back arrow on...

Страница 14: ...emedy of the consumer DPI shall not be liable for any incidental or consequential damages for breach of any expressed or implied warranty on this product Except to the extents provided by applicable law any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this warranty Some states do not allow the exclusion or limitat...

Отзывы: