background image

12 

  Reflash  and  upgrade  the  internal  microcontroller  firmware.  Currently,  this 

option is only available from the factory. Please contact the RMA department 
to have the product returned for upgrade. 

  Download  charge  history  and  recent  charge  data.  Visit  the  product 

information on the company website: 

www.DPIpower.com

 to download APPs 

specifically developed to work with these products. 

 
 

9.  WIRELESS CONNECTION AND USE (-C01 Model Only) 

 

Download, Install APP (for wireless product model only: ‘-C01’) 

  Look for the APP on the Google Play Store, ‘DPI 10-Channel C01 Charger’ 

  Download the app and install it 

  Open the APP and follow the easy guide instructions to connect your mobile 

device 

  As of the date of print of this manual, I-Phone is not yet supported 

 
With these APPs, the following functions are possible: 

  Voltage and Charge Amps for all channels, displayed 

  Charge  Status  such  as  ‘Charging’  or  ‘Charged’  are  displayed  via  color 

indicator 

  Error messages for any channel are displayed 

  Multiple Chargers operating in the same vicinity can be named with  Aliases 

and identified 

  Read and/or set the Real Time clock 

 

USING THE APP: 

 
Establishing Aliases For Multiple Charger Devices: 

  Users  can  discover  available  devices  and  setup  an  alias  for  each  device. 

When  the  APP  is  first  started,  press  the  SCAN  button  to  list  all  of  the 
currently  active  devices  within  reception  range.  When  a  device  is  first 
discovered it will be listed by an identifier starting with letters "BLE". 

  User  can  then  setup  an  Alias  for  any  device  listed  by  pressing  and  holding 

the device entry. The Alias entry dialog will be displayed, and an Alias Name 
in  text  can  then  be  entered.  After  the  Alias  Name  is  set  for  the  selected 
device,  the  device  will  appear  in  the  list  under  that  Alias  instead  of  "BLE" 
identifier. 

  Best approach for setting Alias Names for multiple devices is to turn ON each 

10-Channel  charger  one  at  the  time,  then  click  "SCAN"  and  set  an  Alias 
Name  for  that  one  device.  Then  repeat  this  operation  for  each  additional 
charger. 

  After devices has been discovered, user can switch to devices monitoring by 

tapping device entry in the list. 

 
 
 

Содержание Xcel 7QP-12F950P25-C00

Страница 1: ...low multi stage charging of various battery types and chemistries Printed material may not represent the latest information available Please visit our web site www DPIpower com for updates to this or other manuals Manual P N MNUL0044 A001 Rev 2 Copyright 2020 DPI IMPORTANT READ AND SAVE THIS SAFETY INSTRUCTION MANUAL KEEP IT WITH OR NEAR CHARGER AT ALL TIMES ...

Страница 2: ...0P25 C01 Wireless option is installed Charge algorithm controls BOTH voltage and current for precise charging LCD Display with Menu Select Microprocessor Controlled Fully Automatic Read Charge Voltage Amperage Errors and more in plain LCD Display Text Up to 500mA Charging Power Per Channel ...

Страница 3: ...of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to persons Do not operate this charger if it has received a sharp blow was dropped or otherwise damaged in any manner Refer to a qualified service agent Charger contains no serviceable parts If it fails during its warranty period contact your dealer to obtain a warrant...

Страница 4: ...ng into contact with eyes Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without caps carefully follow manufacturer s recharging instructions Study all battery manufacturer s specific precautions such as removing or not removing cell caps while charging and recommended rates...

Страница 5: ... of danger caused by a worn receptacle 4 SAFE GROUNDING INSTRUCTIONS Do not remove Ground Pin from charger s Power Supply AC Plug or connect to utility power via an adaptor that bypasses the product s ground pin connection The product must be grounded at all times when connected to utility power This battery charger s Power Supply must be grounded to reduce the risk of electric shock The Power Sup...

Страница 6: ...y s Negative Neg Terminal o Reversing the output connection to a battery should be avoided but will not damage the charger When connected in reverse charging will not start disconnect the charger clip connections from the battery and remake the connections o Approximately 3 seconds after connection to a battery the charger starts its Multi Stage charging process DO NOT connect more than one batter...

Страница 7: ...ODE Battery Type Name Type AH Volts Cell 01 12V General Lead Acid Flooded 32AH 2 400V 02 12V General Lead Acid AGM 32AH 2 450V 03 12V General Lead Acid Flooded 18AH 2 400V 04 12V General Lead Acid AGM 18AH 2 450V 05 12V General Lead Acid Flooded 10AH 2 400V 06 12V General Lead Acid AGM 10AH 2 450V 07 12V General Lead Acid Flooded 5AH 2 400V 08 12V General Lead Acid AGM 5AH 2 450V 09 6V General Lea...

Страница 8: ...l If the Yellow Green LEDs of a particular Channel flash Alternately then charging on that Channel only has terminated due to a Charge Error Condition Refer to the Charge Error Table for a description of the possible causes of failure Resetting a Channel Error is easy disconnect connect DC Cable to battery and or refer to charge error table MENU SELECT BUTTON Depress and hold depressed for approxi...

Страница 9: ... battery d cTOP Top Off Stage Charging battery e cFIN Float Maintenance Stage Charge finished When no battery is connected the bottom left corner of the LCD displays NoBt This corner also displays other codes when necessary and are referenced throughout this manual CHARGE ERROR TABLE LOG ERROR CODE ERROR MESSAGE ERROR DESCRIPTION POSSIBLE CAUSE REMEDY ERR05 B Cel Wrong Type Battery voltage higher ...

Страница 10: ...checks for minimum and maximum cell voltages If a fully charged cell is detected a transition to Charge Complete is done bypassing all other charge stages BULK Charge Stage also known as Constant Current High Power charge charges at a constant current or constant power rate to deliver the bulk of the charge needed Upon completion of this stage approximately 80 of total charge is delivered to the b...

Страница 11: ...ger voltage level Common Traits Applied to All Charge Stages Each Charge Stage employs the use of a Safety Timer to time out and end that stage if the stage process took too long without achieving the desired targeted results Normally each Stage ends when the charger detects that the battery has reached the proper level of charge for that stage However each Charge Stage has a preset timer that lim...

Страница 12: ...annel are displayed Multiple Chargers operating in the same vicinity can be named with Aliases and identified Read and or set the Real Time clock USING THE APP Establishing Aliases For Multiple Charger Devices Users can discover available devices and setup an alias for each device When the APP is first started press the SCAN button to list all of the currently active devices within reception range...

Страница 13: ...cCVT Constant Voltage cTOP Top Off cFIN Finished Maintenance o Channel Charge Amps and Battery Voltage are all displayed along with the colored Channel Status chart above and the values are in real time pertaining to the associated charge Channel o Channel Error text is displayed in RED below the Voltage and Current boxes o User can switch back to Device List Screen by tapping on the back arrow on...

Страница 14: ...emedy of the consumer DPI shall not be liable for any incidental or consequential damages for breach of any expressed or implied warranty on this product Except to the extents provided by applicable law any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this warranty Some states do not allow the exclusion or limitat...

Отзывы: