Sep-15-2013
Figure 7, Basic Direct Connect ID
Figure 8, 2-Wire Layout
Figure 9, 4-wire Layout
The photo on the right shows how the two camera
stages are identified on ShutterBug Pro’s circuit board.
The connections must be made by soldering your
custom made wiring cable to the indicated pads. Use a
temperature controlled soldering iron set for delicate
soldering work.
The Stage-1 and Stage-2 switches are polarity
sensitive. So, they must be wired to match the polarity
of your camera. This can be determined by using a voltmeter across the camera’s shutter
button (switch) contacts during its resting state.
Direct Connect Method:
2-Wire
Not all cameras do a focus when the shutter
button is depressed. Or perhaps you do not
want to use the cameras auto focus feature. If
so, only two wires are needed.
N/A
Not Used
SHUT+
Shutter Positive
SHUT-
Shutter Negative
Direct Connect Method:
4-Wire
Typical wiring for a camera that has an auto
focus stage is accommodated with the 4-wire
scheme.
FOC+
Focus Positive
FOC-
Focus Negative
SHUT+
Shutter Positive
SHUT-
Shutter Negative