AJAH.418266.007RE
14
Index
Description
R/W
Type
Name (number)
Dynamic parameters
0×71
Alarm threshold
3)
R/W
Single (25)
0×73
Preliminary threshold
R/W
Single (25)
0×75
Bottom threshold
R/W
Single (25)
0×77
Algorithm (0 – “Following”; 1 – “Sliding”)
R/W
Single (25)
0×79
Interval quantity (Sliding) 1 - 60
R/W
Single (25)
0×7b
Interval time (Sliding) 1 – 65535 s
R/W
Single (25)
0×7d
Sensitivity coefficient, (Sv/h)/cps
R/W
Single (25)
0×7f
Dead time,
s
R/W
Single (25)
0×81
DB accumulated dose, Sv
R/W
Single (25)
0×83
Hours worked, h
R/W
Single (25)
0×85
Self background, Sv·h
-1
R/W
Single (25)
1)
Allowable values of the register “Selection of measured quantity” for this detector are 1, 2 and 3.
2)
Preset by the manufacturer. Code of this device is 17.
3)
Dimension of threshold corresponds to the dimension of measured quantity selected as default.
А.2 Selection of the measured quantity
Register 0×15 allows selection of the default measured quantity. The measured quantity set as
“default” is used by registers:
-
“Instantaneous value” – 0×09;
-
“Combined package: Measurement result of the selected measured quantity” – 0×0f;
-
“Measurement result of the selected measured quantity” – 0×10;
-
“Measurement interval of the selected measured quantity” – 0×13;
-
“Uncertainty of the measurement result” – 0×14.
А.3 Restart of measurement
Register 0×19 is used for restart of measurement of N-th measured quantity. The list of values
written to this register is presented in the table A.2.
Table A.2 – List of values that can be written to the 0×19 register
Written value
Description
0×00
Restart of measurement of selected measured quantity
Value 1, 2, 3
Restart of measurement of corresponding measured quantity
0×ff
Restart of all measurements
А.4 Status register (index 0
×
18)
Status register (index 0×18) is used for determination of the detector status.
B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
The value 0×0000 corresponds to normal state of the detector. Flags of the status register 0×18
is presented in the table A.3.