background image

Table of contents

Introduction

3

Declaration of conformity

3

Safety

4

Installation requirements

4

General

4

Flue or chimney

4

Ventilation of the area

5

Floor and walls

6

Product description

6

Installation

7

Preparation

7

Installing and connecting

8

Use

8

First use

8

Fuel

8

Lighting

9

Burning wood

10

Controlling the air

10

Extinguishing the fire

11

Removing ashes

11

Fog and mist

12

Solving problems

12

Maintenance

12

Chimney

12

Cleaning and other regular maintenance
activities

12

Appendix 1: Technical data

14

Appendix 2: Measurements

15

Appendix 3: Distance from combustible
material

17

Appendix 4: Diagnostic diagram

20

Index

21

2

Subject to change because of technical improvements

Содержание 640 CB

Страница 1: ...PERATING MANUAL WOOD STOVE INSTALLATION ET MODE D EMPLOI POELE A BOIS EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG HOLZ FEUERST TTE INSTRUCCIONES DE INSTALACI N Y USO ESTUFA DE LE A ISTRUZIONI PER L INSTALL...

Страница 2: ...ting 8 Use 8 First use 8 Fuel 8 Lighting 9 Burning wood 10 Controlling the air 10 Extinguishing the fire 11 Removing ashes 11 Fog and mist 12 Solving problems 12 Maintenance 12 Chimney 12 Cleaning and...

Страница 3: ...ot be held liable for any problems or damage resulting from incorrect installation Observe the following safety rules when installing and using the appliance In this manual you can read how the DOVRE...

Страница 4: ...broken or cracked it must be replaced before you can use the appliance again Make sure there is adequate ventilation in the room where the appliance is installed The combustion will be incomplete in c...

Страница 5: ...dings adjacent trees or other obstacles The chimney part outside the house must be insulated The chimney must be at least 4 metres high As a rule of thumb 60 cm above the ridge of the roof If the ridg...

Страница 6: ...ermissible Carpets and rugs must be at least 80 cm away from the fire Protect a flammable floor from possible falling ash in front of the fire with the aid of a fireproof protective plate The protecti...

Страница 7: ...nnect the appliance The top plate is loose on the appliance and can simply be lifted off the appliance By removing removable parts it is easier to move the appliance and to avoid damage Note the locat...

Страница 8: ...the appliance without the fire resistant inner sheets The appliance is now ready for use Use First use When you use the appliance for the first time make an intense fire and keep it going for a good f...

Страница 9: ...creosote Creosote is a highly flammable compound and may cause a chimney fire Lighting You can check whether the flue has enough draught by lighting a ball of paper above the baffle plate A cold flue...

Страница 10: ...will burn more slowly as the oxygen can only reach some logs easily If you want to burn wood for a longer period make a compact stack 4 Close the door of the appliance 5 Close the primary air inlet a...

Страница 11: ...larly than to add many logs at the same time Use the filling door to add fuel to the appliance Extinguishing the fire Do not add fuel and just let the fire go out If a fire is damped down by reducing...

Страница 12: ...end of the heating season you can clean the interior of the appliance thoroughly If necessary first remove the fire resistant inner plates See the chapter Installation for instructions on removing and...

Страница 13: ...quently Lubricate the moving parts such as guide systems hinge pins latches and air slides with heat resistant grease that is available in the specialist trade Touching up damaged paint Small areas of...

Страница 14: ...ature increase measured in measuring section 197 K 215 K Temperature measured downstream from the flue spigot 336 303 C Minimum draught 12 Pa 12 Pa CO emission 13 O2 0 10 0 09 NOx emission 13 O2 81 mg...

Страница 15: ...Appendix 2 Measurements 640CB 09 00095 000_640CB Subject to change because of technical improvements 15...

Страница 16: ...760CB 09 00100 000_760CB 16 Subject to change because of technical improvements...

Страница 17: ...combustible material 640CB Minimum distances in millimetres 09 20017 046 Protective insulated connection pipe Combustible material Incombustible material thickness 100 mm Subject to change because of...

Страница 18: ...0CB Minimum distances in millimetres 09 20017 045 Protective insulated connection pipe Combustible material Incombustible material thickness 100 mm 18 Subject to change because of technical improvemen...

Страница 19: ...of fireproof protective plate A B B 09 20002 004 Minimal dimensions of fireproof protective plate A mm B mm Din 18891 500 300 Germany 500 300 Finland 400 100 Norway 300 100 Subject to change because o...

Страница 20: ...oot deposit hermetically tight no chinks Chimney stack incorrect Sufficiently high above the roof no obstacles in its vicinity Air inlets set incorrectly Open the air inlets completely Appliance conne...

Страница 21: ...from 17 Connection measurements 15 Connection collar fitting 7 Connection collar for connection to chimney 7 Control air supply 11 Control of air 10 Cover Fitting 8 Cover on flue 5 Creosote 11 D Damp...

Страница 22: ...P Paint finish 8 Particulate emission 14 Prevent a chimney fire 11 Primary air inlet 9 R Removal of ashes 11 Remove ashes 11 S Scraper for ash removal 11 Scraper for removing ash 7 11 Screens clean 12...

Страница 23: ...ombustible materials 4 fire resistant inner plates 8 glass broken or cracked 4 13 hot surface 4 regulations 4 stove window cleaner 13 terms and conditions for insurance 4 ventilation 4 5 Weather condi...

Страница 24: ...E O E...

Отзывы: