FOR YOUR SAFETY

What to do if you smell gas:

 

Do not try to light any appli-

ance

  Do not touch any electri-

cal switch: do not use any 

phone in your building.

  Immediately call your gas 

supplier from a neighbour's 

phone. Follow the gas sup-

plier's instructions.

  If you  cannot reach your 

gas  supplier,  call  the  fire 

department.

WARNING:  

Improper installation, adjustment, altera-

tion, service or maintenance can cause 

injury or property damage. Refer to this 

manual. For assistance or additional in-

formation consult an authorized installer, 

service agency or the gas supplier.
FOR YOUR SAFETY

Do not store or use gasoline or other flam

-

mable vapours and liquids in the vicinity of 

this or any other appliance.
Installation and service must be performed 

by an authorized installer, service agency or 

the gas supplier.

PLEASE KEEP THESE INSTRUCTIONS 

FOR FUTURE REFERENCE

Owners &

Installation

 

Man

ual

LISTINGS AND CODE APPROVALS

These gas appliances have been tested 

in accordance with AS4553-2000, NZS 

5262 and have been certified by the 

Australian Gas Association for installa-

tion and operation as described in these 

Installation and Operating Instructions.

Your unit should be serviced annu-

ally by an authorised service person.

918-318b

Models: FG37-NG

 FG37-LPG

Содержание FIREGENIE FG37-LPG

Страница 1: ...onsult an authorized installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners Installation Manual LISTINGS AND CODE ...

Страница 2: ...designed to provide you with all the warmth and charm of a woodstove at the flick of a switch The models FG37 NG and F37 LPG of this series has been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instruc...

Страница 3: ...th Co linear Flex System 12 Gas Connection 12 System Data Chart FG37 12 Conversion from NG to LPG 13 Aeration Adjustment 15 Log Installation 15 Door Installation 16 Gas Pipe Pressure Testing 17 Valve Description 17 Louvre Installation 17 Optional Remote Control Installation 18 Final Check 18 Wiring Diagram 18 Operating Instructions Operating Instructions 19 Lighting Procedure 19 Resetting the Unit...

Страница 4: ...m Sealed Freestanding Gas Stove We have printed a DATA PLATE copy of the contents here for your review The data plate is located on the inside of the drop down pedestal door NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one Australia Only ...

Страница 5: ... 1 The appliance shall be installed in accord ance with the manufacturer s installation instructions local gas fitting regulations municipal building codes water supply regulations electrical wiring regulations with AS5601 2004 AGA gas installation code NZS 5261 New Zealand 2 Installation and repair should be done ONLY by an authorised person 3 DO NOT CONNECT TO MASONARY FLUE 4 This appliance must...

Страница 6: ... ThisapplianceisListedforbedroom installations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation This appliance is Listed for Alcove installations maintainminimumAlcoveclearancesasfollows minimum ceiling height of 1 7m minimum width of 1 0m and a maximum depth of 0 9m A Cross Corner B Flush with Wall Alcove C Flat on Wall Co...

Страница 7: ... non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I see table below Clearance k in mm Spa...

Страница 8: ...ies Ltd Warning Alwaysmaintainrequired clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearancerequirementsbetween the outer wall of the flue pipe and nearby com bustible surfaces is 30mm Be sure to check the flue termination clearance requirements from decks windows soffits gas regulators air supply inlets and public walkways...

Страница 9: ...s in the two diagrams below show all allowable com binations of straight vertical and offset to vertical runs with vertical terminations Maximum one 90o elbow All vertical and offset to vertical flue installations require Flue Restrictor to be set to 32mm open If the flue is ENCLOSED in a chase min size 229mm x 229mm maintain a 32mm clearance to combustibles All Vertical Flue Terminals must be Sim...

Страница 10: ...components screws Locatethescrewsatthebottom of the pipe so that the screw heads are hidden on the final installation Apply sealant Mill Pac to inner pipe and high temp silicone sealant or Mill Pac to outer pipe on every joint Hint Apply sealant to female end c Before connecting the flue pipe to the flue termination slide the black decora tivewallthimblecoveroverthefluepipe then slide the Wall Pen...

Страница 11: ...ypresent the possibility of a fire b The location of the horizontal flue termination on an exterior wall must meet all local and national building codes and must not be blocked or obstructed For External Flue Terminal Locations see diagram on page 7 c Snorkel Terminations For installations requiring a vertical rise on the exterior of the building Astro Riser Vent Terminations as shown in Dia 2 is ...

Страница 12: ...he piping system by closing its individual manual shut off valve during the testing AERATION VERTICAL TERMINATION WITH CO LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE This appliance is designed to be attached to two 3 76mm co linear aluminium flex running the full length of the chimney See the Fluing Arrangements chart on ...

Страница 13: ...everse steps 16 15 12 Jumper Location Jumper 8 Remove the NG orifice and replace it with the LPG orifice 9 Install the pilot tube to the pilot assembly 10 Placethepilotassemblyoverthepilotextru sion tube and secure it with 2 screws 11 Adjust the burner areation setting to fully open and install the burner 12 Remove the pedestal back cover by remov ing the 4 Philips screws Pilot Tube 7 Lift the pil...

Страница 14: ...ectoperation of the modulator it is necessary that the plastic cap A is returned to its original location 23 At the end of all setting and adjustment operations check electrical insulation and gas leaks 24 Reverse step 20 25 Check operation of fan and flame control 26 Check for proper flame appearance and glow on logs Cable Electric Modulator 22 Adjusting the Outlet Pressure All the adjustments mu...

Страница 15: ...nty LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation The gas log kit contains the following a 02 65 Rear Log b 02 56 Middle Left Log c 02 44 Front Left Log d 02 46 Left Top Log e 02 45 Front Right Log f 02 47 Center Log g 02 48 Middle Right Log h Emb...

Страница 16: ...e latch catch inward Cutout Pin Notch D 02 46 B 02 56 A 02 65 E 02 45 Bracket A 02 65 The bottom right edge of Log G 02 48 must sit snugly against the bracket Side View G 02 48 E 02 45 F 0 2 4 7 or outward See diagram 3 Note The door latch may require ad justment as the doorgasketmateri alcompressesafter a few fires and after glass replacement Turnthelatchcatch inward or outward on Log B 02 56 and...

Страница 17: ...is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressuretap s usinga5 16 8mm IDhose 4 Light the pilot and turn the valve to ON position Read manometer 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label...

Страница 18: ... and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug This heater does not require a 240VA C supply forthegascontroltooperate A240VA C power supply ...

Страница 19: ...pliance if service is to be performed FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining ...

Страница 20: ...resulting in some cracking and ticking sounds will be heard throughout the cycling process SUMMARY OF CONTROLS On Off Button Iftheunit isswitchedoff pressingandreleasing this button once will switch the unit on The unit will resume its last settings If the unit is switched on pressing and releasing this button once will switch the unit off Flame Increase If the unit is switched on pressing and rel...

Страница 21: ...UCTIONS WARNING DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION Part 918 332a for ECS units except for FG38 Colours Black on Grey except for parts indicated as being Red Size 100 Feb 8 06 Changed AG 601 to AS5601 2004 as per Paul Watters AS NZS 5601 Apr 19 18 Changed to AS NZS 5601 as per R D ...

Страница 22: ... annu ally by an authorized field service person to ensure that the flow of combustion and ventilation air is not obstructed During the annual service call the burners should be removed from the burner tray and cleaned Replace the embers do not block the pilot or burner ports 5 Keep the area near the appliance clear and free from combustible materials gasoline and other flammable vapours and liqui...

Страница 23: ...nds butt tight together on the bottom edge of the door 8 Replace door on the stove and check the seal MAINTENANCE LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool beforeopeningdoortocarefullyremovethelogs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper repla...

Страница 24: ...ould be plugged directly into a properly grounded three prong receptacle Do not cut orremovethegroundingprongfrom IMPORTANT Disconnect power supply before servicing this plug TO REMOVE FAN 1 Unplug or disconnect power source to stove 2 Remove the rear access panel on the back of the stove The fan can only be accessed from the back of the stove 3 Unclip the wires from the fan motor 4 Lift fan off o...

Страница 25: ...t pedestal door and unhook chain You may want to put a soft cloth on thebaseoftheunitsothatwhenthepedestal doorisopenitdoesn tscratchthepaint See diagram below 5 Remove the front plate by undoing the 6 screws 6 Disconnect the manual switch cable and reset cables 7 Disconnect the gas pipe line at the valve 8 Remove the pedestal back cover by remov ing the 4 Philips screws 9 Disconnect the 5 pin mol...

Страница 26: ... N A N A N A N A N A N A 910 088 Spark Cable N A N A N A N A N A N A N A 910 084 Control Box 910 527 Manual Control Switch N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cable 4 2 N A 2 2 1 4 3 N A 2 910 912 Ignition Module to Valve Cable N A N A N A 910 906 Reset Switch N A N A 910 083 Ignition Module 1 910 922...

Страница 27: ...24 948 255 Door Latch c w J Hook 25 Flex Pipe 3 ID FG37 MAIN ASSEMBLY Part Description Part Description Part Description 26 Clamp for Flex Pipe 27 910 233 Fan Auto On Off Thermodisc 28 Mounting Brckt Thermodisc 29 Air Deflector 30 680 030 Rear Panel 31 630 021 Fan Access Panel 32 730 565 Firebox Baffle Restrictor As sembly 33 640 520 False Top Assembly 35 630 011 Air Passage Gasket 38 820 058 Pede...

Страница 28: ...240 37 Orifice NG 936 170 Orifice Gasket 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 71 730 528 Log Stand 904 390 Pilot Orifice 52 NG 75 732 930 Log Set 78 730 550 Burner Assy NG LP Part Description Part Description PARTS LIST 82 630 009 Gasket Burner Tray Air Passage 83 630 008 Gasket Burner Tray Firebox 90 910 386 Thermocouple 91 910 341 Thermopile 69 732 930 Log Set 92 Rear Log 93 Left Top...

Страница 29: ...e 730 926 Black Mitred Door Complete 730 932 Gold Wrap Door Complete 730 928 Gold Panel Door Complete 101 650 920 Door Gasket Kit 105 Ceramic Paper 106 940 323 P Side Glass 107 936 243 Glass Gasket 108 940 322 P Centre Glass 111 Door Frame Fibre Paper 112 750 015 Door Glass Extrusion 208 940 325 P Wrap Glass Not available as a replacement part ...

Страница 30: ...30 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater NOTES ...

Страница 31: ...me war ranty to the original purchaser of a Regency Product The Warranty Lifetime Covered under the agreement are the following compo nents Combustion chamber heat exchanger burner tubes logs embers glass thermal breakage and all gold plating against defective manufacture The above will be covered for parts and labour for the first five years and parts only thereafter Electrical components such as...

Страница 32: ...alled _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions ev...

Отзывы: