2000DV - 2080DV
47
03.27987.000
Slide the roof plate (4), USDPAL 10, over the pipe and screw it tight.
Seal the seam between the pipe and the roof plate cone using a silicone kit and
in some cases a storm collar (5), USSR 10, making it watertight.
Install the roof terminal (6), USDVC2 10, and secure it using the clamp supplied.
Seal the roof plate, making it watertight.
Vent passage through a pitched roof made of combustible material
Beginning from the unit assemble the concentric pipes one by one, including the
desired slanted sections, following the path you previously laid out, to just be-
neath the roof.
Determine the place for roof vent passage.
5
4
1
3
2
6
min. 400 mm
50 mm
6
3
5
4
1
2