2000DV - 2080DV
44
03.27987.000
3.3.3. Installation with horizontal (wall) terminal
General directions
Ducts and vent sleeves must be at least 50 mm away from combustible material,
everywhere.
All elements of both the air intake and flue gas exhaust systems must be insert-
ed into each other to a minimum of 30 mm and be secured by the use of clamps,
USKB 10, or stainless steel screws.
For outlets in the vicinity of a property line or ventilation openings you are re-
ferred to the applicable national and regional codes.
Choice of the outlet area
The flue gas outlet can reach a temperature of 200 °C. Therefore, it is important
to choose the outlet area with care in order to prevent any person from possibly
coming into contact with the flue gas outlet.
The temperature of the flue gasses themselves from this type of unit can run as
high as ca. 400 °C Outlets beneath overhangs and awnings can be dangerous
due to the accumulation of hot combustion gasses and are therefore not permit-
ted.
3.3.2. Installing the restrictor plate
The restrictor plate is installed at the top inside the combustion chamber of the unit
and serves to adapt the draught in the unit to the pipe path that has been worked
out.
The restrictor plate can be installed in 4 positions, indicated with 0, 1, 2 and 3, as
shown in the figure below.
When the unit is delivered the plate is installed in position 0. If a different position
is required, the plate simply has to be unscrewed and reinstalled in the position
required.
position 1
position 0
position 2
position 3
Positions of the restrictor plate
Содержание 2000DV
Страница 2: ...2000DV 2080DV 2 03 27987 000...
Страница 3: ...2000DV 2080DV 3 03 27987 000 2000DV CLASSIC 2000DV DIAMOND 2000DV PRISMA 2080DV PRISMA...
Страница 74: ...2000DV 2080DV 74 03 27987 000...
Страница 76: ...2000DV 2080DV 76 03 27987 000 Bijlage 2 Afmetingen Annexe 2 Dimensions 2000DV CLASSIC 2000DV DIAMOND...
Страница 77: ...2000DV 2080DV 77 03 27987 000 Annex 2 Dimensions Anlage 2 Abmessungen 2000DV PRISMA 2080DV PRISMA...