10
WILDEN PUMP & ENGINEERING, LLC
Step 7.
Figure 7
NOTE:
Due to varying torque values, one
of the following two situations may occur:
1) The outer piston, diaphragm and inner
piston remain attached to the shaft and
the entire assembly can be removed from
the center section
(Figure 7).
Step 8.
Figure 8
2) The outer piston, diaphragm, inner
piston, and disc spring separate from the
shaft which remains connected to the
opposite side diaphragm assembly
(Figure
8).
Teflon
®
-fitted pumps come standard
with back-up diaphragms (not shown).
Step 9.
Figure 9
To remove the diaphragm assembly from
the shaft, secure shaft with soft jaws (a
vise fitted with plywood or other suitable
material) to ensure shaft is not nicked,
scratched, or gouged. Using an
adjustable wrench, remove diaphragm
assembly from shaft. Inspect all parts for
wear and replace with genuine Wilden
parts if necessary.
(Figure 9)
Step 4.
Figure 4
Remove the discharge valve balls, seats
and o-rings from the discharge manifold
and inspect for nicks, gouges, chemical
attack or abrasive wear. Replace worn
parts with genuine Wilden parts for reli-
able performance. Teflon
®
o-rings
should be replaced when reassembled.
(Figure 4)
Step 5.
Figure 5
Inspect the valve seat, valve seat o-ring,
and valve ball from intake manifold.
Check for nicks, gouges, chemical attack
or abrasive wear. Replace worn parts with
genuine Wilden parts for reliable perfor-
mance. Teflon
®
o-rings should be
replaced when reassembled.
(Figure 5)
Step 6.
Figure 6
With the
3
⁄
4
" box wrench or by rotating the
diaphragm by hand, remove the dia-
phragm assembly.
(Figure 6)
WIL_14070_E_01.qxd 1/4/06 6:29 AM Page 10
Содержание WILDEN BioPharm T2 Series
Страница 1: ...WIL_14070_E EOM T2M BIOPHARM 2 05 WIL_14070_E_01 qxd 1 4 06 6 29 AM Page C1...
Страница 15: ...13 WILDEN PUMP ENGINEERING LLC NOTES WIL_14070_E_01 qxd 1 4 06 6 29 AM Page 13...
Страница 19: ...WIL_14070_E_01 qxd 1 4 06 6 29 AM Page BC1...
Страница 20: ...WIL_14070_E_01 qxd 1 4 06 6 29 AM Page BC2...