4 7
P
OWER
AND
C
OMMUNICATION
Figure 2. Install snap bushing on
access hole that carries power
and phone cords.
POWER OUTLET
ACCESSIBILITY
Whether you are installing a new
outlet, or plan to use an existing
outlet to supply power to the ATM,
make sure the following require-
ments are met:
1.
The outlet is located near the
cabinet.
2.
The outlet is easily accessible.
3.
Access to the outlet will not be
blocked once the cabinet is in-
stalled!
POWER SUPPLY CORD
SPECIFICATIONS
For European applications, the power
supply cord must conform to the fol-
lowing specifications:
1.
Two-conductor with physical
earth ground.
2.
IEC 320 molded connector on
one end and molded plug on the
other end.
3.
Certified for country of
installation.
4.
Rated minimum H05VV-F with
minimum 0.75 mm2 (except where
specific countries require 1.0
mm2) conductors.
5.
Maximum length: 3 meters.
Содержание Triton FT5000
Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK 8 FT5000 SITE PREPARATION AND INSTALLATION GUIDE ...
Страница 9: ...9 ATM INSTALLATION FOR ACCESSIBILITY ...
Страница 21: ...21 ATM ENVIRONMENTAL PRECAUTIONS CHECKLIST ...
Страница 23: ...23 SITE PREPARATION INSTALLATION Ground exterior ...
Страница 44: ...44 FT5000 SITE PREPARATION AND INSTALLATION GUIDE THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...45 POWER AND COMMUNICATION ...
Страница 48: ...48 THIS PAGE INTENTIONALLY LEFT BLANK FT5000 SITE PREPARATION AND INSTALLATION GUIDE ...
Страница 49: ...49 NMD 100 DISPENSING MECHANISM REMOVAL INSTALLATION ...
Страница 54: ...54 THIS PAGE INTENTIONALLY LEFT BLANK FT5000 SITE PREPARATION AND INSTALLATION GUIDE ...
Страница 55: ...55 REAR SERVICE PANEL RSP TCP IP and VSAT INSTALLATION CONNECTIVITY ...