WIL-11500-E-11
9
PS420/430 Bolted Metal
SECTION 5
PS420/PS430 METAL
RUBBER-FITTED
Ship Weights…420 Threaded AL 26 kg (57 lb)
420 Threaded SS 50 kg (111 lb)
420 Threaded Iron 39 kg (86 lb)
430 Flanged AL 28 kg (62 lb)
430 Flanged SS 53 kg (116 lb)
430 Flanged Iron 42 kg (92 lb)
Air Inlet……………………………………….3/4"
Inlet…………………...…………38 mm (1-1/2")
Outlet………………...………….38 mm (1-1/2")
Suction Lift………………..5.9 m Dry (19.5
′
) AL
9.0 m Wet (29.5
′
) AL
5.5 m Dry (17.9
′
) SS
9.3 m Wet (30.6
′
) SS
5.9 m Dry (19.3
′
) Iron
7.6 m Wet (25.0
′
) Iron
Disp. per Stroke
1
……...…...1.1 L (0.28 gal) AL
1.0 L (0.26 gal) SS
1.0 L (0.26 gal) Iron
Max. Flow Rate……………500 lpm (132 gpm)
Max. Size Solids…………………6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 310 lpm (82 gpm) against
a discharge head of 1.4 bar (20 psig) requires
4.1 bar (60 psig) and 71 Nm
3
/h (42 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
PS420/PS430 METAL
EZ-INSTALL TPE-FITTED
Ship Weights…420 Threaded AL 26 kg (57 lb)
420 Threaded SS 50 kg (111 lb)
420 Threaded Iron 39 kg (86 lb)
430 Flanged AL 28 kg (62 lb)
430 Flanged SS 53 kg (116 lb)
430 Flanged Iron 42 kg (92 lb)
Air Inlet……………………………………….3/4"
Inlet……………………………...38 mm (1-1/2")
Outlet……………………………38 mm (1-1/2")
Suction Lift…………….....5.9 m Dry (19.5
′
) AL
9.0 m Wet (29.5
′
) AL
5.6 m Dry (18.4
′
) SS
9.0 m Wet (29.5
′
) SS
6.2 m Dry (20.4
′
) Iron
8.3 m Wet (27.2
′
) Iron
Disp. per Stroke
1
….……….1.1 L (0.30 gal) AL
1.1 L (0.28 gal) SS
1.0 L (0.25 gal) Iron
Max. Flow Rate……………510 lpm (135 gpm)
Max. Size Solids…………………6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 273 lpm (72 gpm) against
a discharge head of 2.8 bar (40 psig) requires
5.5 bar (80 psig) and 83 Nm
3
/h (49 scfm) air
consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
PERFORMANCE
Содержание PSG Wilden Pro-Flo SHIFT PS420
Страница 26: ...WIL 11500 E 11 26 PS420 430 Bolted Metal NOTES ...
Страница 27: ...WIL 11500 E 11 27 PS420 430 Bolted Metal NOTES ...