PS420/430 Bolted Metal 

 

SECTION 6 

Wilden pumps are designed to meet the performance requirements of 

even the most demanding pumping applications. They have been 
designed and manufactured to the highest standards and are 

available in a variety of liquid path materials to meet your chemical 
resistance needs. Refer to “Performance” for an in-depth analysis of 

the performance characteristics of your pump. Wilden offers the 
widest variety of elastomer options in the industry to satisfy 

temperature, chemical compatibility, abrasion resistance and flex 
concerns. 
 

The suction pipe size should be at least equal to or larger than the 
diameter size of the suction inlet on your Wilden pump. The suction 

hose must be a non-collapsible, reinforced type because these 
pumps are capable of pulling a high vacuum. Discharge piping should 

also be equal to or larger than the diameter of the pump discharge, 
which will help reduce friction losses. 

 

CAUTION:

 All fittings and connections must be airtight. 

Otherwise, pump suction capability will be reduced or lost. 

 
Months of careful planning, study and selection efforts can result in 

unsatisfactory pump performance if installation details are left to 
chance. You can avoid premature failure and long-term dissatisfaction 

by exercising reasonable care throughout the installation process. 
 

Location 

Noise, safety and other logistical factors usually dictate where 

equipment will be situated on the production floor. Multiple 
installations with conflicting requirements can result in congestion of 

utility areas, leaving few choices for additional pumps. 
Within the framework of these and other existing conditions, locate 
every pump in such a way that the following six key factors are 
balanced against each other to maximum advantage: 

 

Access:

 First, the location should be accessible. If it’s easy to 

reach the pump, maintenance personnel will be able to perform 
routine inspections and adjustments more easily. If major 

repairs become necessary, ease of access can play a key role 
in speeding the repair process and reducing total downtime. 

 

Air Supply:

 Every pump location should have an air line large 

enough to supply the volume of air necessary to achieve the 

desired pumping rate. For best results, the pumps should use a 
5

μ

 (micron) air filter, needle valve and regulator. The use of an 

air filter before the pump will ensure that the majority of any 
pipeline contaminants will be eliminated. 

 

Solenoid Operation:

 When operation is controlled by a 

solenoid valve in the air line, three-way valves should be used. 

This valve allows trapped air between the valve and the pump 
to bleed off, which improves pump performance. You can 

estimate pumping volume by counting the number of strokes 
per minute, and then multiplying that figure by the displacement 

per stroke. 

 

Muffler:

 Using the standard Wilden muffler, sound levels are 

reduced below OSHA specifications. You can use other mufflers 
to reduce sound levels farther, but they usually reduce pump 

performance. 

 

Elevation:

 Selecting a site that is well within the pump’s 

dynamic lift capability will assure that loss-of-prime issues will 

be eliminated. In addition, pump efficiency can be adversely 

affected if proper attention is not given to site location. 

 

Piping:

 Final determination of the pump site should not be 

made until the piping challenges of each possible location have 

been evaluated. The impact of current and future installations 
should be considered ahead of time to make sure that 
inadvertent restrictions are not created for any remaining sites. 

The best choice possible will be a site involving the shortest and 
straightest hook-up of suction and discharge piping. Unnecessary 
elbows, bends and fittings should be avoided. Pipe sizes should  

be selected to keep friction losses within practical limits. All piping 
should be supported independently of the pump. In addition,  

the piping should be aligned to avoid placing stress on the  
pump fittings. 

 
Flexible hose can be installed to aid in absorbing the forces created 

by the natural reciprocating action of the pump. If the pump is to be 
bolted down to a solid location, a mounting pad placed between the 
pump and the foundation will assist in minimizing pump vibration. 

Flexible connections between the pump and rigid piping will also 
assist in minimizing pump vibration. If quick-closing valves are 

installed at any point in the discharge system, or if pulsation within a 
system becomes a problem, a surge suppressor (SD Equalizer) 

should be installed to protect the pump, piping and gauges from 
surges and water hammer. 

 
If the pump is to be used in a self-priming application, make sure that 
all connections are airtight and that the suction lift is within the 

model’s ability. 

 

NOTE:

 Materials of construction and elastomer material 

have an effect on suction lift parameters. Please refer to 

“Performance” for specifics. 

 
When pumps are installed in applications involving flooded suction or 

suction head pressures, a gate valve should be installed in the 
suction line to permit closing of the line for pump service. 

 
Pumps in service with a positive suction head are most efficient when 

inlet pressure is limited to 0.5–0.7 bar (7–10 psig). Premature 
diaphragm failure may occur if positive suction is 0.7 bar (10 psig) 

and higher. 
 

Single-Point Exhaust 

Pro-Flo SHIFT pumps can be used for submersible applications when 

using the Pro-Flo SHIFT's single-point exhaust. 

 

CAUTION:

 All Wilden pumps are capable of passing solids. 

Use a strainer on the pump intake to ensure that the pump's 
rated solids capacity is not exceeded. 

 

CAUTION:

 Do not exceed 8.6 bar (125 psig) air  

supply pressure. 

 
 
 

 

 

SUGGESTED INSTALLATION, OPERATION, MAINTENANCE  

AND TROUBLESHOOTING 

Содержание PSG Wilden Pro-Flo SHIFT PS420

Страница 1: ...WIL 11500 E 11 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL PS420 PS430 Bolted Metal Pump ...

Страница 2: ...G California LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are registered and unregistered trademarks of their respective owners Nothing contained in this document should be construed as granting any license or right to use any trademark without the prior written ...

Страница 3: ...Rubber Fitted 9 PS420 PS430 Metal EZ Install TPE Fitted 9 PS420 PS430 Metal Full Stroke PTFE Fitted 10 Suction Lift Capability 11 SECTION 6 Suggested Installation Operation Maintenance and Troubleshooting 12 SECTION 7 Disassembly Reassembly 15 Pump Disassembly 15 Air Valve Center Section Disassembly 18 Single Point Exhaust 21 Reassembly Hints and Tips 21 SECTION 8 Exploded View and Parts List 23 S...

Страница 4: ...ly with all wetted pump components CAUTION Before attempting any maintenance or repair disconnect the compressed air line to the pump and allow all air pressure to bleed from the pump Disconnect all intake discharge and air lines Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container Be aware of any hazardous effects of contact with your process fluid CAU...

Страница 5: ... SANIFLEX HYTREL CREAM FW SANITARY WIL FLEX SANTOPRENE TWO BLACK DOTS NE NEOPRENE GREEN DOT PU POLYURETHANE BROWN TF PTFE WHITE VT FKM WHITE DOT WF WIL FLEX SANTOPRENE THREE BLACK DOTS VALVE SEATS A ALUMINUM BN BUNA N RED DOT EP EPDM BLUE DOT FS SANIFLEX HYTREL CREAM FW SANITARY WIL FLEX SANTOPRENE TWO BLACK DOTS M MILD STEEL NE NEOPRENE GREEN DOT PU POLYURETHANE BROWN S STAINLESS STEEL VT FKM WHI...

Страница 6: ...ts seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A Atmospheric pressure forces fluid into the inlet manifold of the pump The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the liquid chamber FIGURE ...

Страница 7: ...2 K 333 13 1 L 326 12 9 M 531 20 9 N 525 20 7 P 274 10 8 R 224 8 8 S 152 6 0 T 178 7 0 U 11 0 4 LW0231 REV E PS420 METAL VERTICAL PORT DIMENSIONS ITEM METRIC mm STANDARD inch A 442 17 4 B 64 2 5 C 261 10 3 D 391 15 4 E 429 16 9 F 51 2 0 G 249 9 8 H 49 1 9 J 132 5 2 K 333 13 1 L 326 12 9 M 531 20 9 N 525 20 7 P 274 10 8 R 224 8 8 S 152 6 0 T 178 7 0 U 11 0 4 LW0232 REV F DIMENSIONAL DRAWING ...

Страница 8: ... 8 T 178 7 0 U 203 8 0 V 11 0 4 DIN mm ANSI Inch W 150 DIA 5 0 DIA X 109 DIA 4 3 DIA Y 16 DIA 0 6 DIA LW0233 REV D PS430 ALUMINUM DIMENSIONS ITEM METRIC mm STANDARD inch A 442 17 4 B 80 3 1 C 324 12 7 D 531 20 9 E 594 23 4 F 606 23 9 G 122 4 8 H 122 4 8 J 50 2 0 K 132 5 2 L 334 13 1 M 531 20 9 N 312 12 3 P 274 9 7 R 206 8 1 S 152 6 0 T 170 6 7 U 11 0 4 DIN mm ANSI Inch V 150 DIA 5 0 DIA W 109 DIA ...

Страница 9: ... will fall in the center of the pump s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure PS420 PS430 METAL EZ INSTALL TPE FITTED Ship Weights 420 Threaded AL 26 kg 57 lb 420 Threaded SS 50 kg 111 lb 420 Threaded Iron 39 kg 86 lb 430 Flanged AL 28 kg 62 lb 430 Flanged SS 53 kg 116 lb 430 Flanged Iron 42 kg 92 lb Air Inlet 3 4 Inlet 38 mm 1 1 2 Outlet 38 mm 1 1 2 Suction L...

Страница 10: ...oke1 1 1 L 0 30 gal AL 0 9 L 0 24 gal SS 0 9 L 0 24 gal Iron Max Flow Rate 485 lpm 128 gpm Max Size Solids 6 4 mm 1 4 1Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 1 bar 30 psig head pressure Example To pump 280 lpm 74 gpm against a discharge head of 2 1 bar 30 psig requires 5 5 bar 80 psig and 88 Nm3 h 52 scfm air consumption Flow rates indicated on cha...

Страница 11: ... atmospheric pressure and pipe friction loss all affect the amount of suction lift your pump will attain PS420 PS430 STAINLESS STEEL SUCTION LIFT CAPABILITY Suction lift curves are calibrated for pumps operating at 305 m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbo...

Страница 12: ...d then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other mufflers to reduce sound levels farther but they usually reduce pump performance Elevation Selecting a site that is well within the pump s dynamic lift capability will assure that loss of prime issues will be eliminated In addi...

Страница 13: ...used to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss which reduces flow rate See Performance This is useful when the need exists to control the pump from a remote location When the pump discharge pressure equals or exceeds the air supply pressure the pum...

Страница 14: ...o be unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped cavitation 3 Check for sticking ball check valves a If material being pumped is not compatible with pump elastomers swellin...

Страница 15: ...o a suitable container Be aware of any hazardous effects of contact with your process fluid NOTE Your specific pump model may vary from the configuration shown however pump disassembly procedure will be the same NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Step 2 Step 3 Before starting disassembly mark a line from each liquid chamber to its corresponding air ch...

Страница 16: ...old to expose the valve balls and valve seats Inspect ball cage area of manifold for excessive wear or damage Step 7 Step 8 Step 9 Remove the inlet valve balls and valve seats from the inlet manifold and liquid chambers and inspect for nicks gouges chemical attack or abrasive wear Replace worn parts with genuine Wilden parts for reliable performance Using the appropriate sized wrench remove the li...

Страница 17: ...with genuine Wilden parts for reliable performance To remove the diaphragm assembly from shaft secure shaft with soft jaws aluminum plastic or plywood to ensure the shaft is not damaged Using an adjustable wrench remove the diaphragm assembly from the shaft Remove outer piston and stud if equipped Inspect for wear and replace if necessary DISASSEMBLY REASSEMBLY ...

Страница 18: ...ur process fluid NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Step 2 Step 3 Using a pair of snap ring pliers remove the snap ring from the pilot sleeve Using an O ring pick remove the O ring from modulator spool Using the appropriate sized wrench loosen and remove the fasteners that attach the air chamber to the center section Step 4 Step 5 Step 6 Lift the air ...

Страница 19: ...r to the spool or O rings and replace if necessary Using the appropriate sized wrench loosen the fasteners and lift away remaining air chamber and center block gasket from center section Replace gasket if necessary Step 10 Step 11 Step 12 Using an O ring pick remove the two 2 shaft bushings from center block Inspect and replace if necessary Using an O ring pick gently remove the two 2 Glyd rings f...

Страница 20: ...n the end cap using an O ring pick Replace the O ring s if necessary NOTE The Pro Flo SHIFT air valve incorporates an end cap at both ends of the air valve Step 15 Remove the air valve spool from the air valve body by threading one air valve bolt into the end of the air valve spool and gently sliding the spool out of the air valve body Inspect seals for signs of wear and replace the entire air val...

Страница 21: ...torque specifications are on this page The following tips will assist in the assembly process Lubricate the air valve bore center section shaft and pilot spool bore with NLGI grade 2 white EP bearing grease or equivalent Clean the inside of the center section shaft bore to ensure no damage is done to new shaft seals A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffl...

Страница 22: ...5 With the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the clamp pressure on the pliers This will allow the seal to partially snap back to its original shape 6 After removing the pliers you will notice a slight bump in the seal shape Before the seal can be res...

Страница 23: ...ION 8 PS420 PS430 METAL LW0021 REV L ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS PLASTIC ADS EXPLODED VIEW AND PARTS LIST VERTICAL PORT ALUMINUM FLANGED STAINLESS STEEL AND DUCTILE IRON FLANGED FULL FLOW PTFE FULL STROKE IPD METAL ADS ...

Страница 24: ...r 1 4 MNPT 1 04 3240 07 Wetted Path Components 26 Liquid Chamber 2 04 5015 03 04 5015 01 04 5015 02 27 Manifold Discharge 1 1 2 NPT 1 04 5035 03 04 5035 01 04 5035 02 Manifold Discharge 1 1 2 BSPT 1 04 5036 03 04 5036 01 04 5036 02 Manifold Discharge Vert 1 1 4 NPT 1 04 5037 03 04 5037 01 04 5037 02 Manifold Discharge Vert 1 1 4 BSPT 1 04 5038 03 04 5038 01 04 5038 02 Manifold Discharge 1 1 2 ANSI...

Страница 25: ... 1080 52 50 04 1128 52 Geolast 04 1022 15 EPDM 04 1010 54 08 1080 54 50 04 1128 54 FDA EPDM 04 1010 74 FKM 04 1010 53 08 1080 53 50 04 1128 53 PTFE 04 1040 55 42 04 1085 55 71 1281 55 1 Non Food Grade Saniflex 04 1031 46 Saniflex 04 1065 56 04 1022 56 04 1031 56 08 1080 56 50 04 1128 56 FDA Wil Flex 04 1065 57 04 1022 57 04 1031 57 04 1128 57 Wil Flex 04 1022 58 04 1031 58 08 1080 58 50 04 1128 58...

Страница 26: ...WIL 11500 E 11 26 PS420 430 Bolted Metal NOTES ...

Страница 27: ...WIL 11500 E 11 27 PS420 430 Bolted Metal NOTES ...

Страница 28: ... USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document WIL 11500 E 11 Where InnovationFlows ...

Отзывы: