![Dover PSG Wilden Pro-Flo 230/SSPPP Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/dover/psg-wilden-pro-flo-230-ssppp/psg-wilden-pro-flo-230-ssppp_engineering-operation-and-maintenance_2525036021.webp)
WIL-11570-E-03
Wilden
®
21
Disassembly / Reassembly
Shaft Seal Installation
Pre-Installation
After all of the old seals have been removed, the inside of the
bushing should be cleaned to ensure no debris is left that may
cause premature damage to the new seals.
Installation
1.
To prevent damaging the inside surface of the new seal,
wrap electrical tape around each leg of the needle-nose
pliers. (Heat shrink tubing may also be used.)
2.
With a new seal in hand, place the two legs of the needle-
nose pliers inside the seal ring. (See Figure A.)
3.
Open the pliers as wide as the seal diameter will allow,
then with two fingers pull down on the top portion of the
seal to form a kidney bean shape. (See Figure B.)
4.
Lightly clamp the pliers together to hold the seal into the
kidney shape. Be sure to pull the seal into as tight of a
kidney shape as possible. This will allow the seal to travel
down the bushing bore with greater ease.
5.
With the seal clamped in the pliers, insert the seal into the
bus- ing bore and position the bottom of the seal into the
correct groove. When the bottom of the seal is seated in
the groove, release the clamp pressure on the pliers. This
will allow the seal to partially snap back to its original
shape.
6.
After removing the pliers you will notice a slight bump in
the seal shape. Before the seal can be resized properly,
the bump in the seal should be removed as much as
possible. This can be done with either a Phillips
screwdriver or your finger. With the side of the screwdriver
or your finger, apply light pressure to the peak of the
bump. This pressure will cause the bump to be eliminated
almost completely.
7.
Lubricate the edge of the shaft with NLGI grade 2 white
EP bearing grease.
8.
Slowly insert the center shaft with a rotating motion. This
will complete the resizing of the seal.
9.
Repeat these steps for the remaining seals.
Tools
The following tools can be used to aid in the installation of the
new seals:
•
Needle-Nose Pliers
•
Phillips Screwdriver
•
Electrical Tape
Figure A
Figure B
PRO-FLO
®
MAXIMUM TORQUE
SPECIFICATIONS
Description of Part
Torque
Air Valve
3.1 N•m (27 in
-lb)
Outer Pistons, All diaphragms
40.7 N•m (30 ft
-lb)
Top and Bottom Manifold
8.5 N•m (75 in
-lb)
Liquid Chamber to Center Section
8.5 N•m (75 in
-lb)