![Dover PSG Wilden Pro-Flo 230/SSPPP Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/dover/psg-wilden-pro-flo-230-ssppp/psg-wilden-pro-flo-230-ssppp_engineering-operation-and-maintenance_2525036018.webp)
WIL-11570-E-03
Wilden
®
18
Disassembly / Reassembly
Air Valve Disassembly
Tools Required:
•
5 mm (3⁄16") Allen
Wrench
•
Snap-Ring Pliers
•
O-Ring Pick
CAUTION
: Before any maintenance or repair is attempted, the compressed air line to the pump
should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake,
discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into
a suitable container. Be aware of hazardous effects of contact with your process fluid.
The Wilden P220/P230 metal pump uses the revolutionary Pro-Flo
®
air distribution system. A 6 mm
(1⁄4") air inlet connects the air supply to the center section. Proprietary composite seals reduce the
coefficient of friction and allow the pump to run lube-free. Constructed of polypropylene, the Pro-
Flo
®
air distribution system is designed to perform in on/off, non-freezing, non-stalling, tough duty
applications.
Step 1
Loosen the air valve bolts utilizing a 5 mm
(3⁄16") Allen wrench.
Step 2
Remove muffler plate and air valve bolts
from air valve assembly exposing muffler
gasket for inspection. Replace if
necessary.
Step 3
Lift away air valve assembly and remove
air valve gasket for inspection. Replace if
necessary.