Disassembly / Reassembly
Pump Disassembly
Tools Required:
•
13 mm (1/2") Box Wrench
•
2
–
25 mm (1") Sockets
or Adjustable Wrench
•
Adjustable Wrench
•
Vise equipped with
soft jaws (such as plywood,
plastic or other suitable material)
CAUTION:
Before any maintenance or repair is attempted, the compressed air line
to the pump should be disconnected and all air pressure allowed to bleed from the
pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it
upside down and allowing any fluid to flow into a suitable container. Be aware of
any hazardous effects of contact with your process fluid.
NOTE:
The model photographed is a metal PX200 25 mm (1") pump. Your specific
pump model may vary from configuration shown; however, pump disassembly
procedure will be the same.
NOTE:
The model used for these instructions incorporates rubber diaphragms and
balls. Models with PTFE diaphragms and balls are the same except where noted.
Step 1
Please note alignment marks on center
section. Use to properly align liquid chamber
to center section.
Step 2
Using a 13 mm (1/2") wrench, loosen
the discharge manifold from the liquid
chambers.
Step 3
Remove the discharge manifold to expose
the valve balls, valve seats and valve seat
O-rings.