WIL-11570-E-03
Wilden
®
10
PERFORMANCE
P220/P230 METAL
REDUCED-STROKE
PTFE-FITTED
Ship Weig ht ............. Aluminum 11 kg (24 lb)
Ductile Iron 21 kg (47 lb)
316 Stainless Steel 23 kg (51 lb)
Air Inlet .........................................6 mm (1/4")
Inlet ...............................................25 mm (1")
Outlet ........................................... 25 mm (1")
Suctio n Lift.......................... 3.5 m Dry (11.4')
9.3 m Wet (30.6')
Disp. Per Stroke
1..........................................
0.23 L (0.06 gal)
Max. Flo w Rate .................. 168 lpm (44 gpm)
Max. Size Solids ........................ 6.4 mm (1/4")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 45.4 lpm (12 gpm)
against a discharge pressure head of
3.2 bar (47 psig) requires 4.1 bar (60 psig)
and 34 Nm
3
/h (20 scfm) air consumption.
(See dot on chart.)
P220/P230 METAL
FULL-STROKE
PTFE-FITTED
Ship Weig ht ... Stainless Steel23 kg (51 lb)
Aluminum 11 kg (24 lb)
Cast Iron 21 kg (47 lb)
Air Inlet .................................... 6 mm (1/4")
Inlet .......................................... 25 mm (1")
Outlet ........................................25 mm (1")
Suctio n Lift.......................
5.5m Dry (18.2’)
9.0 m Wet (29.5')
Disp. Per Stroke
1.....................................
0.3 L (0.08 gal)
Max. Flo w Rate ............. 185 lpm (49 gpm)
Max. Size Solids .................... 6.4 mm (1/4")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 75.7 lpm (20 gpm)
against a discharge head of 3.1 bar
(45 psig) requires 4.1 bar (60 psig) and
36.9 Nm
3
/h (23 scfm) air consumption
Flow rates indicated on chart were determined by pumping water.
For optimum life and performanc e, pumps should be specified so that daily
operation parameters will fall in the center of the
pump's
performanc e curve.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.