ALF-13080-E-01
All-Flo
13
7
SECTION
STEP 7
In order to remove both “Outer
Chambers” use two ¾ Inch
wrenches. Remove ten “Hex-Head
Cap Screws (1/2”-13x2-1/4”)”, ten
“Flat and Lock Washers (1/2”)” and
eight “Flanged Hex Nuts (1/2”-13)”
from each “Outer Chamber”.
(Air ratchet may also be used as
shown in image)
STEP 8
Remove both “Outer Chambers”
from the “Intermediate.”
STEP 9
Using two 1 Inch wrenches,
remove “Outer Diaphragm Plate”,
“Diaphragm”, “Inner Diaphragm
Plate” and “Nut” from one side
of the pump.
STEP 10
Placing the 1 inch wrench on the
“Outer Diaphragm Plate”, and the
1 1/16 inch socket on the “Nut”,
remove the “Inner Diaphragm
Plate”.
STEP 11
Remove “inner diaphragm plate”
and “outer diaphragm plate” from
“diaphragm.”
PUMP WET END ASSEMBLY
To assemble the wet end of the pump, reverse the order of disassembly.
Ensure all hardware is fastened in accordance with torque specifications
(see page 18). Inverting one of the diaphragms during reassembly will