Appendix A - Pump Control Test Checklist
Pump Control (PCM, DPC)
Pump Control 1 Position
Number
1
2
3
4
5
6
7
8
Write down associated pump number
Verify the correct pump turns on
Verify pump timers are set up as required
Verify maximum quantity is set up as required - Using card with no quantity restriction setup verifies
pump turns off when maximum quantity is reached.
Verify pump records the correct amount
Verify Product restriction is set up properly Set up test card for each product restriction and verify
card can only turn on proper pump(s)
Verify Quantity restriction is set up properly Set up test card for each quantity restriction and verify
card can only pump the restricted quantity
Verify if pump is equipped with OPW AVI nozzle reader that pump can be authorized with tag
Pump Control (PCM, DPC)
Pump Control 2 Position
Number
1
2
3
4
5
6
7
8
Write down associated pump number
Verify the correct pump turns on
Verify pump timers are set up as required
Verify maximum quantity is set up as required - Using card with no quantity restriction setup verifies
pump turns off when maximum quantity is reached.
Verify pump records the correct amount
Verify Product restriction is set up properly Set up test card for each product restriction and verify
card can only turn on proper pump(s)
Verify Quantity restriction is set up properly Set up test card for each quantity restriction and verify
card can only pump the restricted quantity
Verify if pump is equipped with OPW AVI nozzle reader that pump can be authorized with tag
M1700 FSC3000 Installation Manual | Dover Fueling Solutions
72
Содержание Petro Vend FSC3000
Страница 1: ...Petro Vend FSC3000 Installation Manual Part Number M1700 Revision 15 1 FSC3000 ...
Страница 7: ...Warranty 78 M1700 FSC3000 Installation Manual Dover Fueling Solutions 7 ...
Страница 65: ...3 2 3 3 Gilbarco Secure Prompts DTC M1700 FSC3000 Installation Manual Dover Fueling Solutions 65 ...
Страница 79: ......