2.6 Physical Configuration
2.6.1 FSC3000 Access Connections – Baud Rate Setting
Set connection baud rate to desired connection rate (default 38400). Unless needed, it is recommended that
the FSC3000 access baud rate be set to 38400 for maximum ARTWare
™
performance.
NOTE:
When using pass-thru port-connected devices, the FSC3000 access baud rate must
be the same as the device that is being connected to the pass-thru port. If possible, set the
device to the highest setting the FSC3000 supports.
2.6.2 Direct-Connect Serial Communication to PC
Set the communication parameters as follows:
l
Baud Rate: Up to 38400
l
Data Bits: 7
l
Parity: Even
l
Stop: 1
2.6.3 PC Connection via Dial-In
This method uses the optional internal modem you remotely connect to the FSC3000 via an analog phone
line.
Set the communication parameters as follows:
l
Baud Rate: Up to 38400
l
Data Bits: 7
M1700 FSC3000 Installation Manual | Dover Fueling Solutions
39