Dover Mouvex A15 Скачать руководство пользователя страница 7

7/16

NT 1101-B00 11 13  A15 - AS15 e

2.12 Alignment of motor / pump and reduction

gearbox / pump shafts

To check the alignment and coupling, use a set square to
control the axial misalignment and feeler gauges for angu-
lar misalignment.

It is important to control the alignment at every step of
installation in order to ensure that none of these steps
generates stress on the pump unit or the pump itself :

• after fastening on foundations

• after fastening the piping

• after the pump has operated at normal operating

temperature.

REMINDER :

Do not rely on the flexible coupling to compensate for
misalignment.

2.13 Electric motors

Check that the supply voltage matches the indications
on the motor rating plate.

Comply with the wiring diagram, make sure the wires are
rated for the power and take care with the contacts
which must be thoroughly tightened.

The motors must be protected by appropriate circuit
breakers and fuses.

Connect the regulatory ground connections.

Check the direction of rotation :

This fundamental checking of the pump must be done
without any product, with the inlet and outlet circuit open
to the air, for example, to avoid any risk of an unexpec-
ted pressure rise. Start the pump empty to check the cor-
rect operation of the connections and check that the
direction of rotation corresponds to installation's inlet
and outlet direction. Follow the instructions below if
necessary to change the direction of rotation.

Three phase motor : switch any two wires of the current
supply.

Two phase motor : switch the two wires of the same
phase.

Single phase motor : comply with the instructions of the
manual supplied with the motor.

OPERATION WITHOUT THE SHAFT
PROTECTOR CAN CAUSE SERIOUS
PERSONAL INJURY, MAJOR PROPERTY
DAMAGE, OR DEATH.

WARNING

Do not operate

without guard 

in place.

OPERATION WITHOUT THE SHAFT
PROTECTOR CAN CAUSE SERIOUS
PERSONAL INJURY, MAJOR PROPERTY
DAMAGE, OR DEATH.

WARNING

Do not operate

without guard 

in place.

DISCONNECT THE ELECTRICITY SUPPLY
BEFORE ANY MAINTENANCE OPERATION.

WARNING

Dangerous voltage.

Can cause 

injury and death

.

Carry out the control at four points :
at the top - at the bottom - left - right 

Correct

Bad alignment

Angular fault

DISCONNECT THE ELECTRICITY SUPPLY
BEFORE ANY MAINTENANCE OPERATION.

WARNING

Dangerous voltage.

Can cause 

injury and death

.

2. INSTALLATION (continued)

Содержание Mouvex A15

Страница 1: ...NANCE INSTRUCTIONS 1101 B00 e Section 1101 Effective November 2013 Replaces New Original instructions Your distributor Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com ...

Страница 2: ...lert to the potential for personal injury death or major property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards that CAN cause personal injury or property damage NOTICE Indicates special instructions which are very important and must be followed S...

Страница 3: ...3 16 NT 1101 B00 11 13 A15 AS15 e 1 1 A15 model 1 OVERALL DIMENSIONS ...

Страница 4: ...4 16 NT 1101 B00 11 13 A15 AS15 e 1 2 AS15 model 1 OVERALL DIMENSIONS continued Shaft end detail ...

Страница 5: ...al and precise directions However we recall that it is never prejudicial to plan for wide piping diameters particularly regarding the intake For the discharge it is also possible to plan for a diame ter equal to that of the pump s orifices and on the inta ke for a wider diameter if suction is very strong In the case of viscous products the determination of this dia meter is very important since th...

Страница 6: ...line with the conditions of the application hose material rotation speed temperature etc In order for the pump to generate the normally required flow MOUVEX recommends using a vacuum draw kit inside the body of the pump In all cases when using a vaccum kit suction pressure must not be lower than 0 9 barg 13 psig If a vacuum draw kit is not used on an ABAQUE pump operating with suction pressure low...

Страница 7: ...any product with the inlet and outlet circuit open to the air for example to avoid any risk of an unexpec ted pressure rise Start the pump empty to check the cor rect operation of the connections and check that the direction of rotation corresponds to installation s inlet and outlet direction Follow the instructions below if necessary to change the direction of rotation Three phase motor switch an...

Страница 8: ... ensure that the consistency of the deposi ted products will not affect the start up of the pump 3 5 Starting up the pump Before starting up the pump always ensure that the pum ping conditions are correct with the corresponding valves open especially the inlet valve For use at temperatures below 0 C 32 F specific pre cautions must be taken Refer to LUBRICATION 3 6 Shutting down the pump When shutt...

Страница 9: ...OTES To insure an optimal life cycle of the hose it is recom mended to replace the worn lubricant by some new lubricant during any replacement of hose The hose may contain a certain volume of the pumped fluid but this will be expelled when restarting the pump Evacuation of this fluid may also be carried out by run ning the pump after having taken all the safety measu res required for personal and ...

Страница 10: ...dy 1 with screws 33 and washers 34 NOTES If the pump is not re assembled immediately dry unpainted surfaces and coat them with the pump lubricant in order to protect them against corrosion Dispose of the drained products in accordance with the rules and regulations in force NOTE If the pump is not re assembled immediately dry unpainted surfaces and coat them with the pump lubri cant in order to pr...

Страница 11: ... screws 48 and washers 49 Fit snap ring 24 in the groove provided for this purpose on the insert Appropriately tighten clamp 7 on hose boot 6 Make sure that it is not cut 7 take care on the direction of assem bly of the hose clamp it must be directed so that the part presenting a lively fish bone is side body Tighten hose clamp 9 onto nipple 6 and hose 16 the screw should be tightened to the stop ...

Страница 12: ...cone Remove the wheel 3 by sliding it along the central axis 4 2 2 ASSEMBLING THE WHEEL Check the shaft seal 26 Replace when necessary making sure that it is assembled so that the spring can be seen inside the pump body Check that the wheel have no dents or deep scratches that may quickly dereriorate the hose Insert the parts of the hub 19 in the wheel center Slide wheel 3 with its hub 19 on the a...

Страница 13: ...000 8000 10000 12000 14000 16000 18000 20000 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 0 5 10 20 30 40 50 60 70 80 90 Max viscosity cps Flowrate m3 h Motor power kW Rotation speed rpm 3 bar 5 bar 8 bar Coutinuous service Intermittent service Max viscosity Max service 122 F Max service 140 F Max service 158 F Max service 176 F 0 10000 20000 30000 40000 ...

Страница 14: ...shed with a cleaning agent that is compatible with the hose material and the pumped product It is recommended that the hose be monitored so that it can be replaced before any breakdown should occur Preventive replacement is advisable Temperature threshold values for the liquid pumped depend directly on the materials that make up the hose Refer to technical characteristics on the cover page for the...

Страница 15: ...sure drop at inlet Check the inlet line see 2 4 PIPE DIAMETERS WEAK FLOW The pump hose is damaged Replace the hose see 4 1 REPLACING THE HOSE The lubricant is not suitable Empty the pump body and replace the lubricant with one that is recommended by MOUVEX The lubricant is dirty or too old Empty the pump body and replace the lubricant with a new MOUVEX lubricant Temperature of the pumped fluid is ...

Страница 16: ...elektrische Risiken die für rotierende Maschinen gelten NF EN 809 2009 NF EN 1672 2 2009 NF EN ISO 13857 2008 NF EN 12162 2009 ATEX Richtlinie 94 9 EG 23 März 1994 wie umgesetzt im nationalen Recht in Bezug auf Ausrüstungen für den Einsatz in explosionsgefährdeter Atmosphäre Die Konformität hat Geltung durch Anwendung folgender Normen NF EN 1127 1 1997 NF EN 13463 1 2009 NF EN 13463 5 2009 Die ATE...

Отзывы: