FILLING WITH LUBRICANT :
Loosen plug
11
and plug
23
located at the top of the body.
Fill the pump body with lubricant (see § LUBRICATION).
Tighten plugs
11
and
23
in the body.
Run the pump for a few minutes to check correct operation.
Reinstall the inlet and discharge piping.
Put the leak detection kit back in place, if the pump is
equipped with one.
In the event that the breathing vent has been removed,
check the installation direction for the existing back flow valve
(the valve must allow air out and block it from entering).
4.2 Re-assembling and disassembling the
wheel
Disassembly and reassembly of the wheel
3
are required
when :
- Replacing the shaft seal
26
.
- Performing a complete overhaul.
- Disassembling or replacing the bearing box or the
reduction gear.
For disassemble the wheel
3
, the pump hose must be
removed (see § REPLACING THE HOSE).
4.2.1 DISASSEMBLING THE WHEEL
Loosen screws
19a
in the hub
19
.
Tighten one of the screws
19a
into the tapped hole of the
hub
19
provided to pull out the cone.
Remove the wheel
3
by sliding it along the central axis.
4.2.2 ASSEMBLING THE WHEEL
Check the shaft seal
26.
Replace when necessary,
making sure that it is assembled so that the spring can
be seen inside the pump body.
Check that the wheel have no dents or deep scratches
that may quickly dereriorate the hose.
Insert the parts of the hub
19
in the wheel center.
Slide wheel
3
with its hub
19
on the axis.
Align wheel
3
with pump body
1
while keeping setting
distance as indicated on the following diagram :
After checking that the expansible hub is properly cente-
red with regard to the wheel thickness, gradually tighten
screws
19a
while keeping wheel alignment correct.
Keying distance (L) :
50 ± 1 mm
(1,969± 0,039 in)
CAUTION
Slippery lubricant.
Spills should be
cleaned up.
NOTES
Screws
19a
must not be tightened so the wheel
assembly can freely slide along the axis.
The flat side of the wheel
3
must be positioned on the
front side of the pump as well as the screws
19a
of
the expansible hub.
NOTES
Handle the lubricant with care.
Wear suitable clothes and protect yourself from pump
lubricant spatters.
THE PUMP LUBRICANT IS VERY SLIPPERY
AND MAY CAUSE SERIOUS INJURY. ANY
SPILLS MUST BE CLEANED UP.